background image

1 Table of contents

Installation manual

5

RZAG71~Y1
Sky Air Alpha-series
4P485927-1C – 2019.04

Table of contents

1 About the documentation

5

1.1

About this document..................................................................

5

2 About the box

5

2.1

Outdoor unit...............................................................................

5

2.1.1

To remove the accessories from the outdoor unit.......

5

3 Preparation

6

3.1

Preparing the installation site ....................................................

6

3.1.1

Installation site requirements of the outdoor unit ........

6

4 Installation

6

4.1

Mounting the outdoor unit..........................................................

6

4.1.1

To provide the installation structure ............................

6

4.1.2

To install the outdoor unit............................................

6

4.1.3

To provide drainage ....................................................

6

4.1.4

To prevent the outdoor unit from falling over ..............

7

4.2

Connecting the refrigerant piping ..............................................

7

4.2.1

To connect the refrigerant piping to the outdoor unit ..

7

4.3

Checking the refrigerant piping .................................................

8

4.3.1

Checking refrigerant piping: Setup..............................

8

4.3.2

To check for leaks.......................................................

8

4.3.3

To perform vacuum drying ..........................................

8

4.4

Charging refrigerant ..................................................................

8

4.4.1

About charging refrigerant ..........................................

8

4.4.2

About the refrigerant ...................................................

9

4.4.3

To determine the additional refrigerant amount .......... 10

4.4.4

To determine the complete recharge amount ............. 10

4.4.5

Charging refrigerant: Setup......................................... 11

4.4.6

To charge additional refrigerant .................................. 11

4.4.7

To activate/deactivate the vacuum mode field setting

11

4.4.8

To completely recharge refrigerant ............................. 11

4.4.9

To fix the fluorinated greenhouse gases label ............ 11

4.5

Connecting the electrical wiring.................................................

12

4.5.1

About electrical compliance ........................................ 12

4.5.2

Guidelines when connecting the electrical wiring ....... 12

4.5.3

Specifications of standard wiring components............ 12

4.5.4

To connect the electrical wiring on the outdoor unit.... 12

4.6

Finishing the outdoor unit installation ........................................

13

4.6.1

To finish the outdoor unit installation .......................... 13

4.6.2

To check the insulation resistance of the compressor

14

5 Commissioning

14

5.1

Checklist before commissioning ................................................

14

5.2

To perform a test run .................................................................

14

5.3

Error codes when performing a test run ....................................

15

5.4

Dedicated field settings for technical cooling ............................

15

6 Disposal

15

7 Technical data

16

7.1

Service space: Outdoor unit ......................................................

16

7.2

Piping diagram: Outdoor unit.....................................................

17

7.3

Wiring diagram: Outdoor unit ....................................................

17

1

About the documentation

1.1

About this document

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry  and  on  farms,  or  for
commercial use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

Business Portal (authentication required).

2

About the box

2.1

Outdoor unit

2.1.1

To remove the accessories from the
outdoor unit

ENERG

IJA

Y

IA

IE

ENERG

IJA

Y

IA

IE

2

3

1

a

b

c

d

e

a

General safety precautions

b

Outdoor unit installation manual

c

Cable tie

d

Fluorinated greenhouse gases label

e

Energy label

Summary of Contents for SkyAir RZAG125M7V1B

Page 1: ...Installation manual Sky Air Alpha series English Installation manual Sky Air Alpha series RZAG71M7V1B RZAG100M7V1B RZAG125M7V1B RZAG140M7V1B RZAG71M7Y1B RZAG100M7Y1B RZAG125M7Y1B RZAG140M7Y1B...

Page 2: ...1000 1000 500 HD HU HU a b 100 100 c d e eB eD A B C D E HB HD A B C 200 300 1000 A B C E 200 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 HD HU 250 1500 HU HD HU 300 1500 B D E HB H...

Page 3: ...onforme altera o em 10 11 12 13 14 15 16 17 Direktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m...

Page 4: ...PS vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplo...

Page 5: ...2 To check the insulation resistance of the compressor 14 5 Commissioning 14 5 1 Checklist before commissioning 14 5 2 To perform a test run 14 5 3 Error codes when performing a test run 15 5 4 Dedica...

Page 6: ...d supply as follows mm 150 6 2 0 350 3 4 5 3 5 5 4 M12 a a Make sure not to cover the drain holes of the bottom plate of the unit INFORMATION The recommended height of the upper protruding part of the...

Page 7: ...b c d INFORMATION b b b b a a Remove the knockout hole a in the bottom plate or cover plate by tapping on the attachment points with a flat head screwdriver and a hammer Optionally cut out the slits...

Page 8: ...flare nut and the copper flare 1 Charge the system with nitrogen gas up to a gauge pressure of at least 200 kPa 2 bar It is recommended to pressurize to 3000 kPa 30 bar in order to detect small leaks...

Page 9: ...efrigerant circuit so the vacuuming process or recharge of refrigerant can be done properly Before vacuum drying or recharging activate field setting vacuum mode After finishing vacuum drying or recha...

Page 10: ...of twin triple and double twin 1 Determine G1 and G2 G1 m Total length of x liquid piping x 9 5 mm standard x 12 7 mm size up G2 m Total length of 6 4 mm liquid piping 2 Determine R1 and R2 If Then G...

Page 11: ...When 2 28 is reached press the BS3 button once 4 Change the setting to 1 by pressing the BS2 button once 5 Push the BS3 button once 6 When the display is not blinking anymore press the BS3 button aga...

Page 12: ...onnected to public low voltage systems with input current 16 A and 75 A per phase RZAG71 140M7Y1B Equipment complying with EN IEC 61000 3 2 European International Technical Standard setting the limits...

Page 13: ...e of the 3 possibilities a b a b a b 2 3 1 a Power supply cable b Interconnection cable Connecting to the frame When cables are routed from the unit a protection sleeve for the conduits PG insertions...

Page 14: ...g field wiring has been carried out according to this document and the applicable legislation Between the local supply panel and the outdoor unit Between the outdoor unit and the indoor unit master Be...

Page 15: ...oor unit and user interface The fuse on the outdoor unit PCB has blown out E3 E4 or L8 The stop valves are closed The air inlet or air outlet is blocked E7 There is a missing phase in case of three ph...

Page 16: ...nimum service space between the unit and obstacles A B C D and E eB Maximum distance between the unit and the edge of obstacle E in the direction of obstacle B eD Maximum distance between the unit and...

Page 17: ...e Outdoor Outdoor Indoor Indoor Upper Upper Lower Lower Fan Fan ON ON OFF OFF 2 Layout English Translation Layout Layout Front Front Back Back Position of compressor terminal Position of compressor te...

Page 18: ...t breaker 30 mA Q1E Overload protection R1 R8 A1P Y1 only Resistor R1T Thermistor air R2T Thermistor discharge R3T Thermistor suction R4T Thermistor heat exchanger R5T Thermistor heat exchanger middle...

Page 19: ......

Page 20: ...4P485927 1C 2019 04 Copyright 2017 Daikin 4P485927 1 C 00000007...