7 Technical data

Installation manual

17

RZAG71~Y1
Sky Air Alpha-series
4P485927-1C – 2019.04

7.2

Piping diagram: Outdoor unit

LPS

HPS

sv

A

B

Charge port / Service port (with 5/16" flare)

Stop valve

Filter

Check valve

Pressure relief valve

Solenoid valve

Heat sink (PCB)

Capillary tube

Electronic expansion valve

4‑way valve

High pressure switch

LPS

Low pressure switch

Compressor accumulator

Heat exchanger

Compressor

Distributor

Liquid receiver

Flare connection

A

Field piping (liquid: Ø9.5 flare connection)

B

Field piping (gas: Ø15.9 flare connection)

Heating

Cooling

7.3

Wiring diagram: Outdoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.

(1) Connection diagram

English

Translation

Connection diagram

Connection diagram

Only for ***

Only for ***

See note ***

See note ***

Outdoor

Outdoor

Indoor

Indoor

Upper

Upper

Lower

Lower

Fan

Fan

ON

ON

OFF

OFF

(2) Layout

English

Translation

Layout

Layout

Front

Front

Back

Back

Position of compressor terminal

Position of compressor terminal

(3) Notes

English

Translation

Notes

Notes

Connection

X1M

Indoor/outdoor communication

Earth wiring

Field supply

English

Translation

1

Several wiring possibilities

Protective earth

Field wire

Wiring depending on model

Option

Switch box

PCB

NOTES:

1

Refer to the wiring diagram sticker (on the back of the front
plate) for how to use the BS1~BS3 and DS1 switches.

2

When operating, do not short-circuit protective devices S1PH
S1PLand Q1E.

3

Refer to the combination table and the option manual for how
to connect the wiring to X6A, X28A and X77A.

4

Colours: BLK: black, RED: red, BLU: blue, WHT: white, GRN:
green

(4) Legend

English

Translation

Legend

Legend

Field supply

Field supply

Optional

Optional

Part n°

Part n°

Description

Description

A1P

Printed circuit board (main)

A2P

Printed circuit board (noise filter)

Summary of Contents for SkyAir RZAG125M7V1B

Page 1: ...Installation manual Sky Air Alpha series English Installation manual Sky Air Alpha series RZAG71M7V1B RZAG100M7V1B RZAG125M7V1B RZAG140M7V1B RZAG71M7Y1B RZAG100M7Y1B RZAG125M7Y1B RZAG140M7Y1B...

Page 2: ...1000 1000 500 HD HU HU a b 100 100 c d e eB eD A B C D E HB HD A B C 200 300 1000 A B C E 200 300 1000 1000 500 D 1000 D E 1000 1000 500 B D HD HU 300 1000 HD HU 250 1500 HU HD HU 300 1500 B D E HB H...

Page 3: ...onforme altera o em 10 11 12 13 14 15 16 17 Direktiver med senere ndringer Direktiv med f retagna ndringar Direktiver med foretatte endringer Direktiivej sellaisina kuin ne ovat muutettuina v platn m...

Page 4: ...PS vastaava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplo...

Page 5: ...2 To check the insulation resistance of the compressor 14 5 Commissioning 14 5 1 Checklist before commissioning 14 5 2 To perform a test run 14 5 3 Error codes when performing a test run 15 5 4 Dedica...

Page 6: ...d supply as follows mm 150 6 2 0 350 3 4 5 3 5 5 4 M12 a a Make sure not to cover the drain holes of the bottom plate of the unit INFORMATION The recommended height of the upper protruding part of the...

Page 7: ...b c d INFORMATION b b b b a a Remove the knockout hole a in the bottom plate or cover plate by tapping on the attachment points with a flat head screwdriver and a hammer Optionally cut out the slits...

Page 8: ...flare nut and the copper flare 1 Charge the system with nitrogen gas up to a gauge pressure of at least 200 kPa 2 bar It is recommended to pressurize to 3000 kPa 30 bar in order to detect small leaks...

Page 9: ...efrigerant circuit so the vacuuming process or recharge of refrigerant can be done properly Before vacuum drying or recharging activate field setting vacuum mode After finishing vacuum drying or recha...

Page 10: ...of twin triple and double twin 1 Determine G1 and G2 G1 m Total length of x liquid piping x 9 5 mm standard x 12 7 mm size up G2 m Total length of 6 4 mm liquid piping 2 Determine R1 and R2 If Then G...

Page 11: ...When 2 28 is reached press the BS3 button once 4 Change the setting to 1 by pressing the BS2 button once 5 Push the BS3 button once 6 When the display is not blinking anymore press the BS3 button aga...

Page 12: ...onnected to public low voltage systems with input current 16 A and 75 A per phase RZAG71 140M7Y1B Equipment complying with EN IEC 61000 3 2 European International Technical Standard setting the limits...

Page 13: ...e of the 3 possibilities a b a b a b 2 3 1 a Power supply cable b Interconnection cable Connecting to the frame When cables are routed from the unit a protection sleeve for the conduits PG insertions...

Page 14: ...g field wiring has been carried out according to this document and the applicable legislation Between the local supply panel and the outdoor unit Between the outdoor unit and the indoor unit master Be...

Page 15: ...oor unit and user interface The fuse on the outdoor unit PCB has blown out E3 E4 or L8 The stop valves are closed The air inlet or air outlet is blocked E7 There is a missing phase in case of three ph...

Page 16: ...nimum service space between the unit and obstacles A B C D and E eB Maximum distance between the unit and the edge of obstacle E in the direction of obstacle B eD Maximum distance between the unit and...

Page 17: ...e Outdoor Outdoor Indoor Indoor Upper Upper Lower Lower Fan Fan ON ON OFF OFF 2 Layout English Translation Layout Layout Front Front Back Back Position of compressor terminal Position of compressor te...

Page 18: ...t breaker 30 mA Q1E Overload protection R1 R8 A1P Y1 only Resistor R1T Thermistor air R2T Thermistor discharge R3T Thermistor suction R4T Thermistor heat exchanger R5T Thermistor heat exchanger middle...

Page 19: ......

Page 20: ...4P485927 1C 2019 04 Copyright 2017 Daikin 4P485927 1 C 00000007...

Reviews: