![background image](http://html1.mh-extra.com/html/daikin/siesta-atxm25n2v1b/siesta-atxm25n2v1b_installers-reference-manual_4701114011.webp)
6 Installation
Installer reference guide
11
ATXM20~50+FTXM20~71N2V1B
Daikin room air conditioner
4P518023-4C – 2018.09
6.3
Installing the indoor unit
6.3.1
Precautions when installing the indoor
unit
INFORMATION
Also read the precautions and requirements in the
following chapters:
▪ General safety precautions
▪ Preparation
6.3.2
To install the mounting plate
1
Install the mounting plate temporarily.
2
Level the mounting plate.
3
Mark the centres of the drilling points on the wall using a tape
measure. Position the end of tape measure at symbol " ".
4
Finish the installation by securing the mounting plate on the wall
using M4×25L screws (field supply).
Class 15~42
Class 50~71
INFORMATION
The removed pipe port cover can be kept in the mounting
plate pocket.
Class 15~42:
337
810
A
294
44.5
170
68
68
44.5
137
137
337
50
213
237
170
A
d
e
(mm)
a
a
f
h
g
a
a
b
a
c
a
c
a
d
e
Class 50~71:
A
990
1040
300
170
60
170
52
52
122
126.5
48
60
435
447
PIPING HOLE
CENTER:170mm
TO THE LEFT
PIPING HOLE
CENTER:170mm
TO THE LEFT
(mm)
A
142
151.5
PIPING HOLE
CENTER:170mm
TO THE LEFT
PIPING HOLE
CENTER:170mm
TO THE LEFT
e
i
j
d
e
d
b
a
c
a
c
a
a
g
h
f
a
a
Recommended mounting plate fixing spots
b
Pocket for the pipe port cover
c
Tabs for placing a spirit level
d
Through-the-wall hole:
e
Drain hose position
f
Position for the tape measure at symbol " "
g
Gas pipe end
h
Liquid pipe end
i
Outline of back side
j
Outline of front side