•  Make sure that a separate power supply circuit is provided 

for this unit and that all electrical work is carried out by 

qualified personnel according to local, state, and national 

regulations. An insufficient power supply capacity or 

improper electrical construction may lead to electric shock 

or fire.

• 

Make sure that all wiring is secured, that specified wires 

are used, and that no external forces act on the terminal 

connections or wires. Improper connections or installation 

may result in fire.

•  When wiring, position the wires so that the electrical 

wiring box cover can be securely fastened. Improper 

positioning of the electrical wiring box cover may result in 

electric shock, fire, or the terminals overheating.

•  Before touching electrical parts, turn off the unit.
•  The circuit must be protected with safety devices in 

accordance with local and national codes, i.e. a circuit 

breaker.

•  Securely fasten the outdoor unit terminal cover (panel). If the 

terminal cover/panel is not installed properly, dust or water 

may enter the outdoor unit causing fire or electric shock.

•  When installing or relocating the system, keep the refrigerant 

circuit free from substances other than the specified 

refrigerant (R410A) such as air. Any presence of air or other 

foreign substance in the refrigerant circuit can cause an 

abnormal pressure rise or rupture, resulting in injury.

•  Do not change the setting of the protection devices. If the 

pressure switch, thermal switch, or other protection device 

is shorted and operated forcibly, or parts other than those 

specified by Daikin are used, fire or explosion may occur.

CAUTION 

• 

Do not touch the switch with wet fingers. Touching a switch 

with wet fingers can cause electric shock.

•  Do not allow children to play on or around the unit to 

prevent injury.

• 

The heat exchanger fins are sharp enough to cut. To avoid 

injury wear gloves or cover the fins while working around 

them.

•  Do not touch the refrigerant pipes during and immediately 

after operation as the refrigerant pipes may be hot or 

cold, depending on the condition of the refrigerant flowing 

through the refrigerant piping, compressor, and other 

refrigerant cycle parts. Your hands may suffer burns or 

frostbite if you touch the refrigerant pipes. To avoid injury, 

give the pipes time to return to normal temperature or, if 

you must touch them, be sure to wear proper gloves.

•  Install drain piping to ensure proper drainage. Improper drain 

piping may result in water leakage and property damage.

•  Insulate piping to prevent condensation.
•  Be careful when transporting the product.
•  Do not turn off the power immediately after stopping 

operation. Always wait for at least 5 minutes before turning 

off the power. Otherwise, water leakage may occur.

•  Do not use a charging cylinder. Using a charging cylinder 

may cause the refrigerant to deteriorate.

•  Refrigerant R410A in the system must be kept clean, dry, 

and tight. 

(a)  Clean and Dry -- Foreign materials (including mineral 

oils such as SUNISO oil or moisture) should be 

prevented from getting into the system.

(b)  Tight -- R410A does not contain any chlorine, does not 

destroy the ozone layer, and does not reduce the earth’s 

protection again harmful ultraviolet radiation. R410A 

can contribute to the greenhouse effect if it is released. 

Therefore take proper measures to check for the tightness 

of the refrigerant piping installation. Read the chapter 

Refrigerant Piping Work

 and follow the procedures.

•  Since R410A is a blend, the required additional refrigerant 

must be charged in its liquid state. If the refrigerant is 

charged in a state of gas, its composition can change and 

the system will not work properly.

•  The indoor unit is for R410A. See the catalog for indoor 

models that can be connected. Normal operation is not 

possible when connected to other units.

•  Remote controller (wireless kit) transmitting distance can be 

shorter than expected in rooms with electronic fluorescent 

lamps (inverter or rapid start types). Install the indoor unit 

far away from fluorescent lamps as much as possible.

•  Indoor units are for indoor installation only. Outdoor units 

can be installed either outdoors or indoors.

•  Do not install the air conditioner or heat pump in the 

following locations:

(a)  Where a mineral oil mist or oil spray or vapor is 

produced, for example, in a kitchen. 

 

Plastic parts may deteriorate and fall off or result in 

water leakage.

(b)  Where corrosive gas, such as sulfurous acid gas, is 

produced.  

Corroding copper pipes or soldered parts may result in 

refrigerant leakage.

(c)  Near machinery emitting electromagnetic waves. 

Electromagnetic waves may disturb the operation of 

the control system and cause the unit to malfunction.

(d)  

Where flammable gas may leak, where there is carbon 

fiber, or ignitable dust suspension in the air, or where 

volatile flammables such as thinner or gasoline are handled. 

Operating the unit in such conditions can cause a fire.

•  Take adequate measures to prevent the outdoor unit 

from being used as a shelter by small animals. Small 

animals making contact with electrical parts can cause 

malfunctions, smoke, or fire. Instruct the user to keep the 

area around the unit clean.

NOTE 

•  The outdoor unit should be positioned where the unit and power 

supply wires (breaker panel to outdoor unit) are at least 10ft (3m) 

away from any televisions or radios. (The unit may cause interference 

with the picture or sound.) Depending on the radio waves, a distance 

of 10ft (3m) may not be sufficient to eliminate the noise.

•  Dismantling the unit, treatment of the refrigerant, oil and 

additional parts must be done in accordance with the 

relevant local, state, and national regulations.

•  Do not use the following tools that are used with 

conventional refrigerants: gauge manifold, charge hose, gas 

leak detector, reverse flow check valve, refrigerant charge 

base, vacuum gauge, or refrigerant recovery equipment.

•  If the conventional refrigerant and refrigerator oil are 

mixed in R410A, the refrigerant may deteriorate.

•  This air conditioner or heat pump is an appliance that 

should not be accessible to the general public.

• 

As design pressure is 604 psi, the wall thickness of field-

installed pipes should be selected in accordance with the 

relevant local, state, and national regulations.

RN003-U

English

01_EN_3P572321-4B.indd   2

2019/10/17   14:46:58

Summary of Contents for RXL18UMVJUA

Page 1: ...is Espa ol MODELS RXL18UMVJU RXL24UMVJU RXL18UMVJUA RXL24UMVJUA DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL R410A Split Series Installation manual Manuel dinstallation Manual de instalaci n Manuel...

Page 2: ...tion hazard could occur leading to serious injury or death Do not ground units to water pipes gas pipes telephone wires or lightning rods as incomplete grounding can cause a severe shock hazard result...

Page 3: ...getting into the system b Tight R410A does not contain any chlorine does not destroy the ozone layer and does not reduce the earth s protection again harmful ultraviolet radiation R410A can contribut...

Page 4: ...n the life of the air conditioner 8 Since water will flow from the drain of the outdoor unit do not place under the unit anything which must be kept away from moisture NOTE Cannot be installed suspend...

Page 5: ...3m in order to avoid noise from the outdoor unit and vibration Mechanical noise and vibration may occur depending on how the unit is installed and the environment in which it is used 10ft 3m O D 5 8 i...

Page 6: ...orientation of the outdoor unit outlet side or use the air direction adjustment grille sold separately Outdoor Unit Installation 1 Installing the outdoor unit When installing the outdoor unit refer to...

Page 7: ...le Make sure that the are nut is tted Set exactly at the position shown below Flaring A Die A 0 0 020 inch 0 0 5mm Clutch type Flare tool for R410A 0 039 0 059 inch 1 0 1 5mm Clutch type Rigid type 0...

Page 8: ...n Gas side Piping size O D 5 8 inch 15 9mm O D 1 4 inch 6 4mm 1 15 16 inch 50mm or more 1 3 16 inch 30mm or more 0 039 inch 1 0mm C1220T O 0 031 inch 0 8mm C1220T O I D 5 8 13 16 inch 16 20mm I D 5 16...

Page 9: ...alve 7 To open the liquid stop valve turn the rod of the valve 90 counter clockwise using a hexagonal wrench Close it after 5 seconds and check for gas leakage Using soapy water check for gas leakage...

Page 10: ...ound crimp style terminal Screw A Arrow view A When connecting the inter unit wires to the terminal block using a single core wire be sure to curl the end of the lead Improper work may cause heat and...

Page 11: ...nd off when using facility settings Do not place humidifiers or other items which might raise the humidity in rooms where facility settings are being used A humidifier might cause dew condensation fro...

Page 12: ...ation For FDMQ models Using the indoor unit s remote controller For wired remote controller 1 Set to COOL operation using the remote controller 2 Press and hold the Cancel button for 4 seconds or long...

Page 13: ...stop the operation press Trial Operation and Testing When trial operation is conducted directly after the circuit breaker is turned on in some cases no air will be output for about 15 minutes in orde...

Page 14: ...Two dimensional bar code is a manufacturing code 3P572321 4B M19B231 1912 HT...

Reviews: