Table of Contents

Installation manual

4

RXF50~71(A)(B)2V1B + RXP50~71L2V1B

R32 split series

3P512025-4C – 2018.01

Table of Contents

1 About the documentation

4

1.1

About this document..................................................................

4

2 About the box

4

2.1

Outdoor unit...............................................................................

4

2.1.1

To remove the accessories from the outdoor unit.......

4

3 Preparation

5

3.1

Preparing the installation site ....................................................

5

3.1.1

Installation site requirements of the outdoor unit ........

5

3.1.2

Additional installation site requirements of the
outdoor unit in cold climates .......................................

5

3.2

Preparing refrigerant piping .......................................................

6

3.2.1

Refrigerant piping requirements..................................

6

3.2.2

Refrigerant piping length and height difference ..........

6

3.2.3

Refrigerant piping insulation .......................................

6

4 Installation

6

4.1

Mounting the outdoor unit..........................................................

6

4.1.1

To provide the installation structure ............................

6

4.1.2

To install the outdoor unit............................................

7

4.1.3

To provide drainage ....................................................

7

4.1.4

To prevent the outdoor unit from falling over ..............

7

4.2

Connecting the refrigerant piping ..............................................

7

4.2.1

Guidelines when connecting the refrigerant piping .....

8

4.2.2

Using the stop valve and service port .........................

8

4.2.3

To connect the refrigerant piping to the outdoor unit ..

8

4.3

Checking the refrigerant piping .................................................

8

4.3.1

To check for leaks.......................................................

8

4.3.2

To perform vacuum drying ..........................................

8

4.4

Charging refrigerant ..................................................................

9

4.4.1

About charging refrigerant ..........................................

9

4.4.2

About the refrigerant ...................................................

9

4.4.3

To determine the additional refrigerant amount ..........

9

4.4.4

To determine the complete recharge amount .............

9

4.4.5

To charge additional refrigerant ..................................

9

4.4.6

To fix the fluorinated greenhouse gases label ............ 10

4.5

Connecting the electrical wiring.................................................

10

4.5.1

Guidelines when connecting the electrical wiring ....... 10

4.5.2

Specifications of standard wiring components............ 10

4.5.3

To connect the electrical wiring on the outdoor unit.... 10

4.6

Finishing the outdoor unit installation ........................................

11

4.6.1

To finish the outdoor unit installation .......................... 11

4.7

About the compressor ...............................................................

11

5 Commissioning

11

5.1

Checklist before commissioning ................................................

11

5.2

Checklist during commissioning ................................................

11

5.3

To perform a test run .................................................................

11

6 Troubleshooting

12

6.1

Fault diagnosis using LED on outdoor unit PCB .......................

12

7 Disposal

12

7.1

To pump down...........................................................................

12

7.2

To start and stop forced cooling ................................................

12

7.2.1

To start/stop forced cooling using the indoor unit ON/
OFF switch.................................................................. 12

7.2.2

To start/stop forced cooling using the indoor unit
user interface .............................................................. 12

8 Technical data

13

8.1

Wiring diagram ..........................................................................

13

8.2

Piping diagram ..........................................................................

14

8.2.1

Piping diagram: Outdoor unit ...................................... 14

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you MUST read before installing

▪ Format: Paper (in the box of the outdoor unit)

Outdoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the outdoor unit)

Installer reference guide:

▪ Preparation of the installation, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Outdoor unit

2.1.1

To remove the accessories from the
outdoor unit

1

Lift the outdoor unit.

2

Remove the accessories at the bottom of the package.

b

e

c

d

a

f

g

a

General safety precautions

b

Outdoor unit installation manual

c

Fluorinated greenhouse gases label

d

Multilingual fluorinated greenhouse gases label

e

Drain plug (located on the bottom of the packing case)

f

Drain cap (1)

g

Drain cap (2)

Summary of Contents for RXF50B2V1B

Page 1: ...Installation manual R32 split series English Installation manual R32 split series RXF50B2V1B RXF60B2V1B RXF71A2V1B RXP50L2V1B RXP60L2V1B RXP71L2V1B...

Page 2: ...tiivej sellaisina kuin ne ovat muutettuina v platn m zn n Smjernice kako je izmijenjeno ir nyelv ek s m dos t saik rendelkez seit z p niejszymi poprawkami 18 19 20 21 22 23 24 25 Directivelor cu amend...

Page 3: ...aava kyll stysl mp tila M C Kylm aine N Varmuuspainelaitteen asetus P bar Valmistusnumero ja valmistusvuosi katso mallin nimikilpi Maxim ln p pustn tlak PS K bar Minim ln maxim ln p pustn teplota TS T...

Page 4: ...ore commissioning 11 5 2 Checklist during commissioning 11 5 3 To perform a test run 11 6 Troubleshooting 12 6 1 Fault diagnosis using LED on outdoor unit PCB 12 7 Disposal 12 7 1 To pump down 12 7 2...

Page 5: ...it with the air inlet facing the wall and NOT directly exposed to the wind b a b c a Baffle plate b Prevailing wind direction c Air outlet Do NOT install the unit in sound sensitive areas e g near a b...

Page 6: ...istance 20 m 3 2 3 Refrigerant piping insulation Pipe outer diameter p Insulation inner diameter i Insulation thickness t 6 4 mm 1 4 8 10 mm 10 mm 12 7 mm 1 2 14 16 mm i i t p p If the temperature is...

Page 7: ...drain holes and attach the drain socket NOTICE In cold areas do NOT use a drain socket hose and caps 1 2 with the outdoor unit Take adequate measures so that the evacuated condensate CANNOT freeze 1...

Page 8: ...hat the refrigerant piping between indoor and outdoor unit is installed in a ducting or the refrigerant piping is wrapped with finishing tape 4 3 Checking the refrigerant piping 4 3 1 To check for lea...

Page 9: ...gerant type R32 Global warming potential GWP value 675 WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING The appliance shall be stored in a room without continuou...

Page 10: ...qualified persons in order to avoid a hazard WARNING Do NOT connect the power supply to the indoor unit This could result in electrical shock or fire WARNING Do NOT use locally purchased electrical pa...

Page 11: ...mounted The system is properly earthed and the earth terminals are tightened The fuses or locally installed protection devices are installed according to this document and have NOT been bypassed The p...

Page 12: ...air going into the operating compressor Use a separate recovery system so that the unit s compressor does NOT have to operate NOTICE During pump down operation stop the compressor before removing the...

Page 13: ...V D DIODE DB DIODE BRIDGE DS DIP SWITCH E H HEATER F U FU FOR CHARACTERISTICS FUSE REFER TO PCB INSIDE YOUR UNIT FG CONNECTOR FRAME GROUND H HARNESS H P LED V L PILOT LAMP LIGHT EMITTING DIODE HAP LIG...

Page 14: ...uT 6 4 CuT 6 4 CuT 6 4 CuT 6 4 CuT 4 0 CuT 4 0 CuT 9 5 CuT 12 7 CuT 12 7 CuT 4 way valve ON heating Propeller fan Discharge pipe thermistor Muffler Muffler Compressor Accumulator Muffler Muffler Muffl...

Page 15: ...uT 6 4 CuT 4 0 CuT 4 0 CuT 4 0 CuT 9 5 CuT 12 7 CuT 12 7 CuT 6 4 CuT 4 way valve ON heating Propeller fan Discharge pipe thermistor Muffler Muffler Compressor Accumulator Muffler Muffler Muffler Gas s...

Page 16: ...3P512025 4C 2018 01 Copyright 2018 Daikin...

Reviews: