Removal Procedure
1. Outer Panels
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
2
Remove the 3 screws
and remove the top
panel.
Remove the 4 screws
of the front panel.
3
4
Unfasten the 2 left side
hooks, and then the 2
right side hooks.
Remove the front panel.
5
Unfasten the 2 hooks
on the top and remove
the discharge grille.
Top panel
Front panel
(R22821)
Hook
(R21605)
Hook
Discharge grille