![background image](http://html1.mh-extra.com/html/daikin/rk09nmvju/rk09nmvju_service-manual_2459825009.webp)
Si001554EA
Electrical Box / PCB
Removal Procedure
7
7
Disconnect the 2
connectors from the
reactor.
When reassembling, you
can reconnect the 2
connectors for the reactor in
either way regardless of the
color.
8
Disconnect the
connector [S90].
[S90]: thermistors
9
Pull out the clamp from
the bottom.
Step
Procedure
Points
Reactor
Connector
(R21620)
[S90]
(R21621)
Clamp
(R21622)