![background image](http://html1.mh-extra.com/html/daikin/rk09nmvju/rk09nmvju_service-manual_2459825008.webp)
Electrical Box / PCB
Si001554EA
6
Removal Procedure
4
Disconnect the
connector [S20].
[S20]: electronic expansion
valve coil
5
Disconnect the
connector [S40].
[S40]: overload protector
6
Disconnect the
connector [S30].
[S30]: compressor motor
Step
Procedure
Points
[S20]
(R21617)
[S40]
(R21618)
[S30]
(R21619)