![background image](http://html1.mh-extra.com/html/daikin/rk09nmvju/rk09nmvju_service-manual_2459825005.webp)
Si001554EA
Outdoor Fan / Fan Motor
Removal Procedure
3
2. Outdoor Fan / Fan Motor
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Step
Procedure
Points
1
Disconnect the
connector [S71] and
remove the filament
tape.
[S71]: fan motor
2
Release the fan motor
lead wire from the
groove.
3
4
Remove the nut of the
outdoor fan.
Remove the outdoor
fan.
Nut size: M6
Align the
mark of the
outdoor fan with the D-cut
section of the motor shaft
when reassembling.
[S71]
Filament tape
(R22822)
Fan motor lead wire
Groove
(R21608)
Nut
Outdoor fan
(R21609)
10 mm
(0.39 inch)
(R18954)