4 About the system

Installation and operation manual

7

FXSA15~140A2VEB
VRV system air conditioner
3P599602-1 – 2020.05

CAUTION

After a long use, check the unit stand
and fitting for damage. If damaged, the
unit may fall and result in injury.

CAUTION

Before accessing terminal devices,
make sure to interrupt all power supply.

DANGER: RISK OF
ELECTROCUTION

To clean the air conditioner or air filter,
be sure to stop operation and turn all
power supplies off. Otherwise, an
electric shock and injury may result.

WARNING

Be careful with ladders when working
in high places.

CAUTION

Turn off the unit before cleaning the air
filter and air outlet.

WARNING

Do NOT let the indoor unit get wet.

Possible consequence: 

Electric

shock or fire.

About the refrigerant (see 

"7.3 About the refrigerant" 

[

4

 10])

WARNING: MILDLY FLAMMABLE
MATERIAL

The refrigerant inside this unit is mildly
flammable.

WARNING

▪ Do NOT pierce or burn refrigerant

cycle parts.

▪ Do NOT use cleaning materials or

means to accelerate the defrosting
process other than those
recommended by the manufacturer.

▪ Be aware that the refrigerant inside

the system is odourless.

WARNING

The refrigerant inside the unit is mildly
flammable, but normally does NOT
leak. If the refrigerant leaks in the room
and comes in contact with fire from a

burner, a heater, or a cooker, this may
result in fire, or the formation of a
harmful gas.

Turn off any combustible heating
devices, ventilate the room, and
contact the dealer where you
purchased the unit.

Do NOT use the unit until a service
person confirms that the part from
which the refrigerant leaked has been
repaired.

WARNING

The appliance shall be stored in a
room without continuously operating
ignition sources (example: open
flames, an operating gas appliance or
an operating electric heater).

WARNING

It is necessary to replace the sensor
after every detection or at the end of
the lifetime. Authorized person only
MUST replace the sensor.

Troubleshooting (see 

"8 Troubleshooting" 

[

4

 11])

WARNING

Stop operation and shut off the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electric shock or fire. Contact your
dealer.

4

About the system

WARNING

▪ Do not modify, disassemble, remove, reinstall or repair

the unit yourself as incorrect dismantling or installation
may  cause  an  electric  shock  or  fire.  Contact  your
dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

Summary of Contents for FXSA15A2VEB

Page 1: ...l VRV system air conditioner English Installation and operation manual VRV system air conditioner FXSA15A2VEB FXSA20A2VEB FXSA25A2VEB FXSA32A2VEB FXSA40A2VEB FXSA50A2VEB FXSA63A2VEB FXSA80A2VEB FXSA10...

Page 2: ...document e normativ e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na...

Page 3: ...un 18 16 Configuration 18 16 1 Field setting 18 17 Technical data 20 17 1 Wiring diagram 20 17 1 1 Unified wiring diagram legend 20 1 About the documentation 1 1 About this document INFORMATION Make s...

Page 4: ...se booster fans in the duct Use the function to adjust the fan rate setting automatically see 16 1 Field setting 418 Refrigerant piping installation see 13 Piping installation 416 CAUTION Do NOT use m...

Page 5: ...operate the unit with wet hands Do NOT place any objects containing water on the unit CAUTION Do NOT place any objects or equipment on top of the unit Do NOT sit climb or stand on the unit Units are...

Page 6: ...for your health to expose your body to the air flow for a long time CAUTION To avoid oxygen deficiency ventilate the room sufficiently if equipment with burner is used together with the system CAUTION...

Page 7: ...r or a cooker this may result in fire or the formation of a harmful gas Turn off any combustible heating devices ventilate the room and contact the dealer where you purchased the unit Do NOT use the u...

Page 8: ...neutral detergent squeeze it well and wipe the panel clean Wipe it with another dry cloth NOTICE NEVER press the button of the user interface with a hard pointed object The user interface may be dama...

Page 9: ...e check the unit stand and fitting for damage If damaged the unit may fall and result in injury NOTICE Do NOT wipe the controller operation panel with benzine thinner chemical dust cloth etc The panel...

Page 10: ...erate the defrosting process other than those recommended by the manufacturer Be aware that the refrigerant inside the system is odourless WARNING The refrigerant inside the unit is mildly flammable b...

Page 11: ...terface displays Notify your installer and report the error code To display an error code see the reference guide of the user interface If the system does NOT operate properly except for the above men...

Page 12: ...nstallation options c a b 1100 b 1100 A B c c d e f mm g 125 b 800 160 160 300 245 h 460 C f g a a A Standard rear suction B Installation with rear canvas duct and duct service opening C Installation...

Page 13: ...d the float switch might malfunction and cause water to drip 12 2 2 Guidelines when installing the ducting WARNING Do NOT install operating ignition sources example open flames an operating gas applia...

Page 14: ...diameter Slope Make sure the drain piping slopes down at least 1 100 to prevent air from being trapped in the piping Use hanging bars as shown 1 1 5 m a a Hanging bar O Allowed X Not allowed Condensat...

Page 15: ...llation of the system is not yet completed 1 Temporarily connect electrical wiring Remove the service cover c Connect the power supply a Connect the user interface b Reattach the service cover L N c a...

Page 16: ...1 4 8 10 mm 10 mm 9 5 mm 3 8 10 14 mm 13 mm 12 7 mm 1 2 14 16 mm 13 mm 15 9 mm 5 8 16 20 mm 13 mm i i t p p If the temperature is higher than 30 C and the humidity is higher than RH 80 the thickness...

Page 17: ...g separated from each other In order to avoid any electrical interference the distance between both wirings should ALWAYS be at least 50 mm NOTICE Be sure to keep the power line and transmission line...

Page 18: ...n the identification label of the unit There are NO loose connections or damaged electrical components in the switch box There are NO damaged components or squeezed pipes on the inside of the indoor a...

Page 19: ...will be off 02 4 After airflow automatic adjustment is finished check if the value number is set to 02 If there is no change perform the setting again To set external static pressure by the user inter...

Page 20: ...Depending on the needs of the user you may disable enable the automatic restart after a power failure If you want auto restart after power failure Then 1 M SW Disabled 12 22 5 01 Enabled 02 17 Technic...

Page 21: ...PTC PTC thermistor Q Insulated gate bipolar transistor IGBT Q C Circuit breaker Q DI KLM Earth leak circuit breaker Q L Overload protector Q M Thermo switch Q R Residual current device R Resistor R T...

Page 22: ......

Page 23: ......

Page 24: ...3P599602 1 2020 05 Copyright 2020 Daikin Verantwortung f r Energie und Umwelt...

Reviews: