background image

• VRV

®

 Systems • Indoor Units

9

• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE

6

Dimensional drawing & centre of gravity

6 - 1 Dimensional drawing

3

1

6

FXHQ100MA

3D038857

Hanging bolt
4 - M8~M10

30 or more

(Service space)

30 or more
(Service space)

(Hanging position)

The front

Brand name plate
(Note 2)

Drain pipe connection VP20
(For left piping)

Position slit hole for taking out in piping back

(View from the front) 

Position: hole of wall
for taking out in piping back
 

(View from the front)

(Required space)

(Required space)

(Required space)

300 or more

For height installation

From the floor side

2500 or more

Floor side

Obstacle

NOTES

1

Location of unit’s name plate: bottom of fan housing inside the 
suction grille.

2

In case of using infrared remote control, this position will be a signal 
receiver. Refer to the drawing of infrared remote control, in detail.

3

The remote control code is standard (about 3m outside the 
machine) attached. (0.5mm

2

 x 2wicks x O.D. ø 5.4) (It is not 

attached to VRV)

Nr

Part name

Description

1

Air discharge grille

2

Air suction grille

3

Air filter

4

Gas pipe connection

ø 15.9 flare

5

Liquid pipe connection

ø 9.5 flare

6

Drain pipe connection

VP20

7

Earth terminal (inside the electric components box)

M4

8

Suspension bracket

9

Backward piping and wiring connection opening lid

10

Upward piping and wiring connection opening lid

11

Right side pipe connection

Slit hole

12

Left back drain pipe connection

Slit hole

13

Left side drain pipe connection

Slit hole

14

Right side drain pipe connection

Slit hole

15

Hole of wall for taking out in piping back

ø 100

16

Upward drain pipe connection

ø 60

17

Upward gas pipe connection

ø 36

18

Upward liquid pipe connection

ø 26

Summary of Contents for FXHQ-MAVE Series

Page 1: ...technical data Ceiling Suspended Unit FXHQ MAVE air conditioning systems...

Page 2: ...Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 5 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 6 Dimensional drawing centre of...

Page 3: ...Indoor Units Ceiling Suspended Unit FXHQ MAVE VRV Systems Indoor Units 2...

Page 4: ...ve Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 36 39 45 Low dBA 31 34 37 Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 Gas Type Flare connectio...

Page 5: ...smaller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXHQ32MAVE FXH...

Page 6: ...adapter marked with 2 Only 1 installation box can be installed per indoor unit FXHQ32MA FXHQ63MA FXHQ100MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7E63W Cooling only BRC7E66...

Page 7: ...6 5 3 8 5 5 5 9 0 5 3 18 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 8 5 3 20 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7 5 2 21 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7...

Page 8: ...7 15 0 5 4 5 4 5 4 5 4 5 4 5 4 12 6 13 0 5 7 5 7 5 7 5 7 5 7 5 7 10 5 11 0 6 0 6 0 6 0 6 0 6 0 5 9 9 5 10 0 6 1 6 1 6 1 6 1 6 1 6 1 8 5 9 1 6 3 6 3 6 2 6 2 6 2 6 2 7 0 7 6 6 5 6 5 6 4 6 4 6 4 6 4 5 0...

Page 9: ...nnection Slit hole 15 Hole of wall for taking out in piping back 100 16 Upward drain pipe connection 60 17 Upward gas pipe connection 36 18 Upward liquid pipe connection 26 FXHQ63MA 3D038856 Hanging b...

Page 10: ...e control this position will be a signal receiver Refer to the drawing of infrared remote control in detail 3 The remote control code is standard about 3m outside the machine attached 0 5mm2 x 2wicks...

Page 11: ...ndoor Units 10 Indoor Units Ceiling Suspended Unit FXHQ MAVE 7 Piping diagram 3 1 7 FXHQ MA 4D034245A Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expansion valve Heat...

Page 12: ...hed to infrared remote control A1P Printed circuit board T1R Transformer 220 240V 22V A2P Printed circuit board C1R Capacitor M1F X1M Terminal block Power A3P Printed circuit board F1U Fuse 5A 250V X2...

Page 13: ...MA NOTES 1 Reference acoustic pressure 0 dB 0 0002 bar 2 Measuring place anechoic chamber 3 Operating noise differs with operation and ambient conditions Data were not available at time of publication...

Page 14: ...Octave band center frequency Hz Approximate threshold hearing for continuous noise FXHQ63MA 4D035302 Octave band sound pressure level dB 0dB 0 0002m bar Octave band center frequency Hz Approximate th...

Page 15: ...Units 14 Indoor Units Ceiling Suspended Unit FXHQ MAVE 10 Air flow pattern 3 1 10 FXHQ100MA Heating Air velocity distribution center air blow Heating Temperature distribution center air blow 2 5m sec...

Page 16: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: