![background image](http://html1.mh-extra.com/html/daikin/fxhq-mave-series/fxhq-mave-series_technical-data-manual_2459728009.webp)
• VRV
®
Systems • Indoor Units
8
• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE
6
Dimensional drawing & centre of gravity
6 - 1 Dimensional drawing
3
1
6
FXHQ32MA
3D038855
Hanging bolt
4 - M8~M10
30 or more
(Service space)
30 or more
(Service space)
(Hanging position)
The front
Brand name plate
(Note 2)
Drain pipe connection VP20
(For left piping)
Position slit hole for taking out in piping back
Position: hole of wall
for taking out in piping back
(View from the front)
(Required space)
(Hanging position)
(Required space)
(Required space)
300 or more
For height installation
From the floor side
2500 or more
Floor side
Obstacle
(View from the front)
NOTES
1
Location of unit’s name plate: bottom of fan housing inside the suction
grille.
2
In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control, in detail.
3
The remote control code is standard (about 3m outside the machine)
attached. (0.5mm
2
x 2 wicks x O.D. ø 5.4) (It is not attached to VRV)
Nr
Part name
Description
1
Air discharge grille
2
Air suction grille
3
Air filter
4
Gas pipe connection
ø 12.7 flare
5
Liquid pipe connection
ø 6.4 flare
6
Drain pipe connection
VP20
7
Earth terminal (inside the electric components box)
M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connectiojn opening lid
11
Right side pipe connection
Slit hole
12
Left back drain pipe connection
Slit hole
13
Left side drain pipe connection
Slit hole
14
Right side drain pipe connection
Slit hole
15
Hole of wall for taking out in piping back
ø 100
16
Upward drain pipe connection
ø 60
17
Upward gas pipe connection
ø 36
18
Upward liquid pipe connection
ø 26
FXHQ63MA
3D038856
Hanging bolt
4 - M8~M10
30 or more
(Service space)
30 or more
(Service space)
(Hanging position)
The front
Brand name plate
(Note 2)
Drain pipe connection VP20
(For left piping)
Position slit hole for taking out in piping back
(View from the front)
Position: hole of wall
for taking out in piping back
(View from the front)
(Required space)
(Hanging position)
(Required space)
(Required space)
300 or more
For height installation
From the floor side
2500 or more
Floor side
Obstacle
NOTES
1
Location of unit’s name plate: bottom of fan housing inside the
suction grille.
2
In case of using infrared remote control, this position will be a signal
receiver. Refer to the drawing of infrared remote control, in detail.
3
The remote control code is standard (about 3m outside the
machine) attached. (0.5mm
2
x 2 wicks x O.D. ø 5.4) (It is not
attached to VRV)
Nr
Part name
Description
1
Air discharge grille
2
Air suction grille
3
Air filter
4
Gas pipe connection
ø 15.9 flare
5
Liquid pipe connection
ø 9.5 flare
6
Drain pipe connection
VP20
7
Earth terminal (inside the electric components box)
M4
8
Suspension bracket
9
Backward piping and wiring connection opening lid
10
Upward piping and wiring connection opening lid
11
Right side pipe connection
Slit hole
12
Left back drain pipe connection
Slit hole
13
Left side drain pipe connection
Slit hole
14
Right side drain pipe connection
Slit hole
15
Hole of wall for taking out in piping back
ø 100
16
Upward drain pipe connection
ø 60
17
Upward gas pipe connection
ø 36
18
Upward liquid pipe connection
ø 26