background image

• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE

• VRV

®

 Systems • Indoor Units

11

8

Wiring diagram

8 - 1 Wiring diagram

3

1

8

FXHQ-MA

3D039801D

Power supply

220-240 V

~

50Hz

220 V

~

60Hz

Note 2

Receiver/display unit

(Infrared remote control)

Note 4

Note 3

Input from 

outside

Note 1

Transmission

wiring centralised 

remote control

Wired remote control

(optional accessory)

Electric parts box

NOTES

1

In case of using centralised remote control, connect it to the unit in accordance with the attached instruction manual.

2

X23A is connected when the infrared remote control kit is being used.

3

When connecting the input wires from the outside, forced off or on/off control operation can be selected by remote control. In details, refer to the installation manual attached to the unit.

4

In case of installing the drain pump, remove the short circuit connector of X8A and execute the additional wiring for float switch and drain pump.

5

Use copper conductors only.

Indoor unit

Receiver/display unit (Attached to infrared remote control)

A1P

Printed circuit board

T1R

Transformer (220-240V/22V)

A2P

Printed circuit board

C1R

Capacitor (M1F)

X1M

Terminal block (Power)

A3P

Printed circuit board

F1U

Fuse (

, 5A, 250V)

X2M

Terminal block (Control)

BS1

Push button (On/off)

HAP

Light emitting diode (Service monitor-green)

Y1E

Electronic expansion valve

H1P

Light emitting diode (On red)

KAR

Magnetic relay (M1S)

 PC

Phase control circuit

H2P

Light emitting diode (Timer green)

KPR

Magnetic relay (M1P)

H3P

Light emitting diode (Filter sign-red)

M1F

Motor (Indoor fan)

Optional parts

H4P

Light emitting diode (Defrost orange)

M1S

Motor (Swing flap)

M1P

Motor (Drain pump)

SS1

Selector switch (Main/sub)

Q1M

Thermo switch (M1F embedded)

SS2

Selector switch (Wireless address set)

R1T

Thermistor (Air)

Wired remote control

Connector for optional parts

R2T

Thermistor (Coil liquid)

R1T

Thermistor (Air)

X8A

Connector (Float switch)

R3T

Thermistor (Coil gas)

SS1

Selector switch (Main/sub)

X18A

Connector (Wiring adapter for electrical appendices)

S1Q

Limit switch (Swing flap)

X23A

Connector (Infrared remote control)

COLORS  :  BLK : Black 

RED : Red

 

  BLU : Blue 

WHT : White

 

  ORG : Orange 

YLW : Yellow

 

  PNK : Pink 

: Terminal
: Connector
: Short circuit connector
: Field wiring

,

Summary of Contents for FXHQ-MAVE Series

Page 1: ...technical data Ceiling Suspended Unit FXHQ MAVE air conditioning systems...

Page 2: ...Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 5 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 6 Dimensional drawing centre of...

Page 3: ...Indoor Units Ceiling Suspended Unit FXHQ MAVE VRV Systems Indoor Units 2...

Page 4: ...ve Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 36 39 45 Low dBA 31 34 37 Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 Gas Type Flare connectio...

Page 5: ...smaller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXHQ32MAVE FXH...

Page 6: ...adapter marked with 2 Only 1 installation box can be installed per indoor unit FXHQ32MA FXHQ63MA FXHQ100MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7E63W Cooling only BRC7E66...

Page 7: ...6 5 3 8 5 5 5 9 0 5 3 18 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 8 5 3 20 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7 5 2 21 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7...

Page 8: ...7 15 0 5 4 5 4 5 4 5 4 5 4 5 4 12 6 13 0 5 7 5 7 5 7 5 7 5 7 5 7 10 5 11 0 6 0 6 0 6 0 6 0 6 0 5 9 9 5 10 0 6 1 6 1 6 1 6 1 6 1 6 1 8 5 9 1 6 3 6 3 6 2 6 2 6 2 6 2 7 0 7 6 6 5 6 5 6 4 6 4 6 4 6 4 5 0...

Page 9: ...nnection Slit hole 15 Hole of wall for taking out in piping back 100 16 Upward drain pipe connection 60 17 Upward gas pipe connection 36 18 Upward liquid pipe connection 26 FXHQ63MA 3D038856 Hanging b...

Page 10: ...e control this position will be a signal receiver Refer to the drawing of infrared remote control in detail 3 The remote control code is standard about 3m outside the machine attached 0 5mm2 x 2wicks...

Page 11: ...ndoor Units 10 Indoor Units Ceiling Suspended Unit FXHQ MAVE 7 Piping diagram 3 1 7 FXHQ MA 4D034245A Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expansion valve Heat...

Page 12: ...hed to infrared remote control A1P Printed circuit board T1R Transformer 220 240V 22V A2P Printed circuit board C1R Capacitor M1F X1M Terminal block Power A3P Printed circuit board F1U Fuse 5A 250V X2...

Page 13: ...MA NOTES 1 Reference acoustic pressure 0 dB 0 0002 bar 2 Measuring place anechoic chamber 3 Operating noise differs with operation and ambient conditions Data were not available at time of publication...

Page 14: ...Octave band center frequency Hz Approximate threshold hearing for continuous noise FXHQ63MA 4D035302 Octave band sound pressure level dB 0dB 0 0002m bar Octave band center frequency Hz Approximate th...

Page 15: ...Units 14 Indoor Units Ceiling Suspended Unit FXHQ MAVE 10 Air flow pattern 3 1 10 FXHQ100MA Heating Air velocity distribution center air blow Heating Temperature distribution center air blow 2 5m sec...

Page 16: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: