background image

Daikin Europe N.V. is approved by LRQA for its Quality
Management System in accordance with the ISO9001
standard. ISO9001 pertains to quality assurance regarding
design, development, manufacturing as well as to services
related to the product. 

Daikin units comply with the European regulations that
guarantee the safety of the product.

Pr

in

ted in B

elgium b

y L

annoo  (www.lannooprint.be)

, a company whose concer

n for

the environm

ont is set in the E

M

AS

 and IS

O 1

4001 systems. 

Responsibl

e E

ditor: 

D

aikin E

urope N.V

., Zandvoor

destraat 300,

 B

- 84

00 Oostende

The present publication is drawn up by way of information only and does not
constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has
compiled the content of this publication to the best of its knowledge. No
express or implied warranty is given for the completeness, accuracy,
reliability or fitness for particular purpose of its content and the products and
services presented therein. Specifications are subject to change without
prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or
indirect damage,  in the broadest sense, arising from or related to the use
and/or interpretation of this publication. All content is copyrighted by Daikin
Europe N.V..

VRV

®

 products are not within the scope of the Eurovent

certification programme.

Naamloze Vennootschap
Zandvoordestraat 300
B-8400 Oostende, Belgium
www.daikin.eu
BTW: BE 0412 120 336
RPR Oostende

Daikin’s unique position as a manufacturer of air
conditioning equipment, compressors and
refrigerants has led to its close involvement in
environmental issues. For several years Daikin has
had the intension to become a leader in the provision
of products that have limited impact on the
environment. This challenge demands the eco design
and development of a wide range of products and an
energy management system, resulting in energy
conservation and a reduction of waste.

ISO14001 assures an effective environmental
management system in order to help protect human health
and the environment from the potential impact of our
activities, products and services and to assist in
maintaining and improving the quality of the environment.

Summary of Contents for FXHQ-MAVE Series

Page 1: ...technical data Ceiling Suspended Unit FXHQ MAVE air conditioning systems...

Page 2: ...Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 5 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 6 Dimensional drawing centre of...

Page 3: ...Indoor Units Ceiling Suspended Unit FXHQ MAVE VRV Systems Indoor Units 2...

Page 4: ...ve Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 36 39 45 Low dBA 31 34 37 Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 Gas Type Flare connectio...

Page 5: ...smaller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXHQ32MAVE FXH...

Page 6: ...adapter marked with 2 Only 1 installation box can be installed per indoor unit FXHQ32MA FXHQ63MA FXHQ100MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7E63W Cooling only BRC7E66...

Page 7: ...6 5 3 8 5 5 5 9 0 5 3 18 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 8 5 3 20 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7 5 2 21 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7...

Page 8: ...7 15 0 5 4 5 4 5 4 5 4 5 4 5 4 12 6 13 0 5 7 5 7 5 7 5 7 5 7 5 7 10 5 11 0 6 0 6 0 6 0 6 0 6 0 5 9 9 5 10 0 6 1 6 1 6 1 6 1 6 1 6 1 8 5 9 1 6 3 6 3 6 2 6 2 6 2 6 2 7 0 7 6 6 5 6 5 6 4 6 4 6 4 6 4 5 0...

Page 9: ...nnection Slit hole 15 Hole of wall for taking out in piping back 100 16 Upward drain pipe connection 60 17 Upward gas pipe connection 36 18 Upward liquid pipe connection 26 FXHQ63MA 3D038856 Hanging b...

Page 10: ...e control this position will be a signal receiver Refer to the drawing of infrared remote control in detail 3 The remote control code is standard about 3m outside the machine attached 0 5mm2 x 2wicks...

Page 11: ...ndoor Units 10 Indoor Units Ceiling Suspended Unit FXHQ MAVE 7 Piping diagram 3 1 7 FXHQ MA 4D034245A Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expansion valve Heat...

Page 12: ...hed to infrared remote control A1P Printed circuit board T1R Transformer 220 240V 22V A2P Printed circuit board C1R Capacitor M1F X1M Terminal block Power A3P Printed circuit board F1U Fuse 5A 250V X2...

Page 13: ...MA NOTES 1 Reference acoustic pressure 0 dB 0 0002 bar 2 Measuring place anechoic chamber 3 Operating noise differs with operation and ambient conditions Data were not available at time of publication...

Page 14: ...Octave band center frequency Hz Approximate threshold hearing for continuous noise FXHQ63MA 4D035302 Octave band sound pressure level dB 0dB 0 0002m bar Octave band center frequency Hz Approximate th...

Page 15: ...Units 14 Indoor Units Ceiling Suspended Unit FXHQ MAVE 10 Air flow pattern 3 1 10 FXHQ100MA Heating Air velocity distribution center air blow Heating Temperature distribution center air blow 2 5m sec...

Page 16: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: