• Indoor Units • Ceiling Suspended Unit • FXHQ-MAVE

• VRV

®

 Systems • Indoor Units

5

2

Safety device settings

3

1

2

3

Options

4

Control systems

3D034597C

FXHQ32MA

FXHQ63MA

FXHQ100MA

PC BOARD FUSE

250V 5A

FAN MOTOR THERMAL PROTECTOR

°

C

OFF:  130

±

5

 / ON: 80

±

20

4D040446A

FXHQ32MA

FXHQ63MA

FXHQ100MA

DRAIN PUMP KIT

KDU50M60VE

KDU50M125VE

KDU50M125VE

REPLACEMENT LONG-LIFE FILTER

Resin net

KAFJ501D56

KAFJ501D80

KAFJ501D112

L-TYPE PIPING KIT FOR UPWARD DIRECTION

KHFP5M35

KHFP5M63

KHFP5M63

Individual control systems

Centralised control systems

Others

3D034600C

NOTES

1

Installation box is necessary for each adapter marked with #

2

Only 1 installation box can be installed per indoor unit

FXHQ32MA

FXHQ63MA

FXHQ100MA

WIRED REMOTE CONTROL

BRC1D52

INFRARED REMOTE CONTROL

Heat pump 

BRC7E63W

Cooling only

BRC7E66

FXHQ32MA

FXHQ63MA

FXHQ100MA

CENTRALISED REMOTE CONTROL

DCS302C51

UNIFIED ON/OFF CONTROL

DCS301B51

SCHEDULE TIMER

DST301B51

FXHQ32MA

FXHQ63MA

FXHQ100MA

WIRING ADAPTER 

KRP1B3

WIRING ADAPTER FOR ELECTRICAL APPENDICES (1)

KRP2A62 #

WIRING ADAPTER FOR ELECTRICAL APPENDICES (2)

KRP4A52 #

REMOTE SENSOR

KRCS01-1

INSTALLATION BOX FOR ADAPTER PCB

KRP1C93 (2)

ELECTRICAL BOX WITH EARTH TERMINAL (3 BLOCKS)

KJB311A

ELECTRICAL BOX WITH EARTH TERMINAL (2 BLOCKS)

KJB212A

NOISE FILTER (FOR ELECTROMAGNETIC INTERFACE USE ONLY)

KEK26-1A

EXTERNAL CONTROL ADAPTER FOR OUTDOOR UNITS (INSTALLATION ON INDOOR UNIT)

DTA104A62 #

Summary of Contents for FXHQ-MAVE Series

Page 1: ...technical data Ceiling Suspended Unit FXHQ MAVE air conditioning systems...

Page 2: ...Hz 4 Electrical Specifications 60Hz 4 2 Safety device settings 5 3 Options 5 4 Control systems 5 5 Capacity tables 6 Cooling capacity tables 6 Heating capacity tables 7 6 Dimensional drawing centre of...

Page 3: ...Indoor Units Ceiling Suspended Unit FXHQ MAVE VRV Systems Indoor Units 2...

Page 4: ...ve Direct drive Refrigerant Name R 410A Cooling Sound Pressure High dBA 36 39 45 Low dBA 31 34 37 Piping connections Liquid OD Type Flare connection Diameter mm 6 35 9 52 9 52 Gas Type Flare connectio...

Page 5: ...smaller than or equal to 4 x FLA Next lower standard fuse rating minimum 15A Select wire size based on the MCA Instead of a fuse use a circuit breaker 1 3 ELECTRICAL SPECIFICATIONS 60HZ FXHQ32MAVE FXH...

Page 6: ...adapter marked with 2 Only 1 installation box can be installed per indoor unit FXHQ32MA FXHQ63MA FXHQ100MA WIRED REMOTE CONTROL BRC1D52 INFRARED REMOTE CONTROL Heat pump BRC7E63W Cooling only BRC7E66...

Page 7: ...6 5 3 8 5 5 5 9 0 5 3 18 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 8 5 3 20 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7 5 2 21 0 4 8 4 1 5 7 4 6 6 6 5 1 7 1 5 2 7 6 5 3 8 5 5 5 8 7...

Page 8: ...7 15 0 5 4 5 4 5 4 5 4 5 4 5 4 12 6 13 0 5 7 5 7 5 7 5 7 5 7 5 7 10 5 11 0 6 0 6 0 6 0 6 0 6 0 5 9 9 5 10 0 6 1 6 1 6 1 6 1 6 1 6 1 8 5 9 1 6 3 6 3 6 2 6 2 6 2 6 2 7 0 7 6 6 5 6 5 6 4 6 4 6 4 6 4 5 0...

Page 9: ...nnection Slit hole 15 Hole of wall for taking out in piping back 100 16 Upward drain pipe connection 60 17 Upward gas pipe connection 36 18 Upward liquid pipe connection 26 FXHQ63MA 3D038856 Hanging b...

Page 10: ...e control this position will be a signal receiver Refer to the drawing of infrared remote control in detail 3 The remote control code is standard about 3m outside the machine attached 0 5mm2 x 2wicks...

Page 11: ...ndoor Units 10 Indoor Units Ceiling Suspended Unit FXHQ MAVE 7 Piping diagram 3 1 7 FXHQ MA 4D034245A Gas pipe connection port Liquid pipe connection port Filter Filter Electronic expansion valve Heat...

Page 12: ...hed to infrared remote control A1P Printed circuit board T1R Transformer 220 240V 22V A2P Printed circuit board C1R Capacitor M1F X1M Terminal block Power A3P Printed circuit board F1U Fuse 5A 250V X2...

Page 13: ...MA NOTES 1 Reference acoustic pressure 0 dB 0 0002 bar 2 Measuring place anechoic chamber 3 Operating noise differs with operation and ambient conditions Data were not available at time of publication...

Page 14: ...Octave band center frequency Hz Approximate threshold hearing for continuous noise FXHQ63MA 4D035302 Octave band sound pressure level dB 0dB 0 0002m bar Octave band center frequency Hz Approximate th...

Page 15: ...Units 14 Indoor Units Ceiling Suspended Unit FXHQ MAVE 10 Air flow pattern 3 1 10 FXHQ100MA Heating Air velocity distribution center air blow Heating Temperature distribution center air blow 2 5m sec...

Page 16: ...ithout prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect damage in the broadest sense arising from or related to the use and or interpretation of this publicat...

Reviews: