Before brazing refrigerant piping, have nitroge
n flow
through the refrigerant piping and substitute air
w
ith
nitrogen (NOTE 2)
(Refer
to
Fig.
13). Then, carry out
brazing (NOTE 3).
After all the brazing
w
orks are
carry out
connection
w
ith the indoor unit.
(Refer
to
Fig.
12)
Pressure reducing valve
Nitrogen
Taping
Stop valve
Brazing place
Nitrogen
Refrigerant piping
Fig.
13
NOT
E
2. The
1.
After indoor unit installation completed, in case will
perform the air tight test of field pipe and indoor unit,
for air tight test pressure, refer the installation manual
attached in outdoor unit.
proper pressure for having nitrogen
through the
piping is approximately 0.02 MPa, a pressure that makes
one feel like breeze and can be obtained through a
pressure reducing valve.
3. Do not use
whe
n brazing refrigerant piping.
Use phosphor copper brazing
metal (BCuP-2: JIS Z
3264/B-Cu93P-710/795: ISO 3677) that does not require
(If chlorinated
is used, the piping
w
ill be corroded and,
in addition if
is contained, the refrig erant oil
w
ill
be deteriorated and the refrigerant circuit
w
ill be affected
badly.)
4. When carrying out leakage test of refrigerant piping and
the indoor unit after the installation of indoor unit is
fin
ished
, confirm
the connecting outdoor unit installation
manual for test pressure.
Refer to also the outdoor unit installation manual or
technical document for refrigerant piping.
5. In case of refrigerant shortage due to forgetting additional
refrigerant charge etc., it
w
ill result in malfunc tion such as
does not cool or does not heat.
Refer to the outdoor unit installation manual or technical
document for refrigerant piping.
CAUTION
Do
not
use
antioxidant
when
brazing
piping.
It may result in malfunction of components and clogging of
piping due to residue.
9
Joint insulating
material (9)
(accessory)
Piping holding plate scre
w
(2 points)
Gas piping
Liquid piping
Liquid side piping insulating method
Indoor unit
Indoor unit
Clamp (4)
(accessory)
Sealing material
(11) Medium-1
(accessory)
Sealing material
(12) Medium-2
(accessory)
Clamp (4)
(accessory)
Piping
insulating
material
(field supply)
Gas side piping insulating method
Joint insulating
material (8)
(accessory)
Piping insulating
material (main unit)
Bring the
seam
to the top.
Flare nut
connection
Piping
insulating
material
(field supply)
Do not leave
clearance.
Flare nut
connection
Bring the
seam
to the top.
Do not leave
clearance.
Piping insulating
material (main unit)
Wind around the
piping until top of the
flare nut connection,
beginning at the base.
Wind around the
piping, beginning
at the base.
Do not expose the
piping in order to
prevent the vapor
condensation.
Tighten the portion
where
overlapped by
the piping insulating
material.
Tighten the portion
where
overlapped by
the piping insulating
material.
Do not expose the
piping in order to
prevent the vapor
condensation.
Fig.
12
Summary of Contents for FXFSQ-AVM
Page 1: ...FXFSQ AVM EDFMT391769A 201802 Engineering Data 50 60 Hz...
Page 2: ......
Page 11: ...FXFSQ AVM EDFMT391769A 9 FXFSQ63AVM FXFSQ80AVM 3D112982A Unit mm...
Page 12: ...FXFSQ AVM EDFMT391769A 10 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112977A Unit mm...
Page 14: ...FXFSQ AVM EDFMT391769A 12 FXFSQ63AVM FXFSQ80AVM 3D112983A Unit mm...
Page 15: ...FXFSQ AVM EDFMT391769A 13 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112979A Unit mm...
Page 17: ...FXFSQ AVM EDFMT391769A 15 FXFSQ63AVM FXFSQ80AVM 3D112985A Unit mm...
Page 18: ...FXFSQ AVM EDFMT391769A 16 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112980A Unit mm...
Page 20: ...FXFSQ AVM EDFMT391769A 18 FXFSQ63AVM FXFSQ80AVM 3D112986A Unit mm...
Page 21: ...FXFSQ AVM EDFMT391769A 19 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112981A Unit mm...
Page 28: ...FXFSQ AVM EDFMT391769A 26 9 Sound Levels FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM 4D112880A 4D112874A...
Page 29: ...FXFSQ AVM EDFMT391769A 27 FXFSQ50AVM FXFSQ63AVM 4D112898A 4D112879B...
Page 30: ...FXFSQ AVM EDFMT391769A 28 FXFSQ80AVM FXFSQ100AVM 4D112878B 4D509733A...
Page 31: ...FXFSQ AVM EDFMT391769A 29 FXFSQ125AVM FXFSQ140AVM 4D509732A 4D509731A...
Page 55: ......