FXFSQ-AVM EDFMT391769A
31
11. Accessories
11.1 Optional Accessories (for Unit)
Item
Model
FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM FXFSQ50AVM FXFSQ63AVM FXFSQ80AVM
Standard panel with
sensing sensor
Fresh white
BYCQ125EEF
Black
BYCQ125EEK
Standard panel
Fresh white
BYCQ125EAF
Black
BYCQ125EAK
Designer panel
(Note 1)
Fresh white
BYCQ125EAPF
Auto grille panel
(Note 2,3)
Fresh white
BYCQ125EASF
Sealing material of
air discharge outlet
(Note 4)
For usage of 3-, 4-way
flow
KDBH551C160
For usage of 2-way
flow
KDBH552C160
Panel spacer
KDBP55H160FA
Fresh air intake kit
Chamber
type
(Note
5,6,8)
Without
T-duct joint
KDDP55B160 [Components : KDDP55C160-1, KDDP55B160-2]
With T-duct
joint
KDDP55B160K [Components : KDDP55C160-1, KDDP55B160K2]
Direct installation type
(Note 7)
KDDP55X160A
High efficiency filter
unit (Including filter
chamber)
(Note 9)
(Colormetric method
65%)
KAFP556C80
(Colormetric method
90%)
KAFP557C80
Replacement high
efficiency filter
(Note 9,10)
(Colormetric method
65%)
KAFP552B80
(Colormetric method
90%)
KAFP553B80
Filter chamber
KDDFP55C160
Replacement long-life filter
KAFP551K160
Replacement long-life filter
(Auto grille panel)
KAFP551H160
Ultra long-life filter unit
(Including filter chamber) (Note 9)
KAFP55C160
Replacement ultra long-life filter (Note 9,10)
KAFP55H160H
Branch duct chamber (Note 4)
KDJP55C80
Insulation kit for high humidity (Note 9,11)
KDTP55K80
C: 3D112950A
Notes:
1. When installing designer panel, body height (ceiling required dimension) is 42 mm higher than standard panel. Designer panel cannot operate
2 and 3 way flow.
2. A dedicated wireless remote controller (BRC16A2) for the auto grille panel is included for lowering and raising the suction grille.
3. When installing auto grille panel, body height (ceiling required dimension) is 55 mm higher than standard panel.
4. Circulation airflow is not available with this option.
5. When installing a fresh air intake kit (chamber type), two air outlet corners are closed.
6. It is recommended that the volume of outdoor air introduced through the kit is limited to 10% of the maximum airflow rate of the indoor unit.
Introducing higher quantities will increase the operating sound and may also influence temperature sensing.
7. The volume of fresh air for direct installation type is approximately 1% of the indoor unit airflow. The chamber type is recommended when
more fresh air is necessary.
8. Please order using the name of both components instead of set name.
9. This option cannot be installed to designer panel and auto grille panel.
10. Filter chamber is required.
11. Please use in case temperature / humidity inside ceiling may get over 30°C, 80%RH.
These panels do not contain the sensing function.
Summary of Contents for FXFSQ-AVM
Page 1: ...FXFSQ AVM EDFMT391769A 201802 Engineering Data 50 60 Hz...
Page 2: ......
Page 11: ...FXFSQ AVM EDFMT391769A 9 FXFSQ63AVM FXFSQ80AVM 3D112982A Unit mm...
Page 12: ...FXFSQ AVM EDFMT391769A 10 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112977A Unit mm...
Page 14: ...FXFSQ AVM EDFMT391769A 12 FXFSQ63AVM FXFSQ80AVM 3D112983A Unit mm...
Page 15: ...FXFSQ AVM EDFMT391769A 13 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112979A Unit mm...
Page 17: ...FXFSQ AVM EDFMT391769A 15 FXFSQ63AVM FXFSQ80AVM 3D112985A Unit mm...
Page 18: ...FXFSQ AVM EDFMT391769A 16 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112980A Unit mm...
Page 20: ...FXFSQ AVM EDFMT391769A 18 FXFSQ63AVM FXFSQ80AVM 3D112986A Unit mm...
Page 21: ...FXFSQ AVM EDFMT391769A 19 FXFSQ100AVM FXFSQ125AVM FXFSQ140AVM 3D112981A Unit mm...
Page 28: ...FXFSQ AVM EDFMT391769A 26 9 Sound Levels FXFSQ25AVM FXFSQ32AVM FXFSQ40AVM 4D112880A 4D112874A...
Page 29: ...FXFSQ AVM EDFMT391769A 27 FXFSQ50AVM FXFSQ63AVM 4D112898A 4D112879B...
Page 30: ...FXFSQ AVM EDFMT391769A 28 FXFSQ80AVM FXFSQ100AVM 4D112878B 4D509733A...
Page 31: ...FXFSQ AVM EDFMT391769A 29 FXFSQ125AVM FXFSQ140AVM 4D509732A 4D509731A...
Page 55: ......