background image

English

8

NOTE

Do not wash the air conditioner with hot water of 
more than 50

°

C, as doing so may result in discol-

oration and/or deformation.

5. Fix the air filter

Refer to “HOW TO CLEAN THE AIR FILTER ”.

6. Reattach the suction grille.

Refer to item No. 2.

7. Close the suction grille.

Refer to item No. 1.

HOW TO DETACH AND REATTACH THE AIR 
FLOW FLAP

1. Detaching the flap

Open the pawl on each end and pull the flap out 
towards you. 

(Refer to Fig. 5)

2. Reattaching the flap

Align the flap’s pawls with the bumps on both 
ends of the air outlet and push gently.

(Refer to Fig. 6)

NOTE

When washing the flap with water, use only soft 
brush or neutral detergent.

START UP AFTER A LONG STOP

Confirm the following

Check that the air inlet and outlet are not blocked.
Remove any obstacle.

Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.

Clean the air filter and outside panels

After cleaning the air filter, make sure to attach it.

Turn on the main power supply switch

The display on the remote controller will be shown 
when the power is turned on.

To protect the unit, turn on the main power switch 
at least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE SYS-
TEM FOR A LONG PERIOD

Turn on FAN OPERATION for a half day and dry 
the unit.

Read the operation manual attached to the 
remote controller.

Cut off the power supply.

Fig. 5

Fig. 6

When the main power switch is turned on, some 
watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving 
energy.

The display on the remote controller will vanish 
when the main power switch is turned off. 

Clean the air filter and the exterior.

Be sure to replace the air filter to its original place 
after cleaning. Refer to “MAINTENANCE”.

The following symptoms do not indicate air condi-
tioner malfunction

I. THE SYSTEM DOES NOT OPERATE

• The system does not restart immediately after 

the ON/OFF button is pressed.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again 
automatically.

• The system does not restart immediately when 

TEMPERATURE SETTING button is returned to 
the former position after pushing the button.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again 
automatically.

• The system does not start when the display 

shows “

” and it flashes for few sec-

onds after pressing an operation button.

This is because the system is under centralized con-
trol. Flashes on the display indicates that the system 
cannot be controlled by the remote controller.

• The system does not start immediately after 

the power supply is turned on.

Wait one minute until the micro computer is pre-
pared for operation.

II. WHITE MIST COMES OUT OF A UNIT

• When humidity is high during cooling opera-

tion (In oily or dusty places)

If the inside of an indoor unit is extremely contam-
inated, the temperature distribution inside a room 
becomes uneven. It is necessary to clean the 
inside of the indoor unit. Ask your Daikin dealer for 
details on cleaning the unit. This operation 
requires a qualified service person.

8. NOT MALFUNCTION OF THE 

AIR CONDITIONER

Summary of Contents for FUQ71BUV1B x 2

Page 1: ...UAL MODELS Ceiling suspended Cassette type FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 English Deutsch Fran...

Page 2: ...dicionador de aire Dicho manual le indicar c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consulte el m...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling pr...

Page 5: ...indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire...

Page 6: ...signated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete install...

Page 7: ...if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leave...

Page 8: ...20 to 15 5 INDOOR TEMPERATURE D B 21 to 32 D B 15 to 27 W B 14 to 25 INDOOR HUMIDITY 80 or below 4 INSTALLATION SITE Pay attention to running noises too Are the following places selected a A place tha...

Page 9: ...gher than the set temperature At defrost oper ation 6 OPTIMUM OPERATION swing Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on...

Page 10: ...W TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral detergent When the flap is extremely contaminated remove it as below and clean...

Page 11: ...roller will vanish when the main power switch is turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to MAINTENANCE The follow...

Page 12: ...tion This continues temporary I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person 9 TRO...

Page 13: ...ified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to the operation manual attached to the remote controller If the FAN SPEED button is set t...

Page 14: ...3P177429 2D EM03A094F 0704 FS HT...