3-2. FXUQ

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.

*To avoid condensation and water dripping out the 

unit.

D

 

B: Dry bulb temperature (

°

C)

WB: Wet bulb temperature (

°

C)

The setting temperature range of the remote con-
troller is 16°C to 32°C.

Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following 

places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels
 f . Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled  with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit 

is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

COOLING

HEATING

OUTDOOR 

TEMPERATURE

D

B

–5 to 43

D

B

–20 to 21

W

B

–20 to 15.5

INDOOR 

TEMPERATURE

D

B

21 to 32

D

B

15 to 27

W

B

14 to 25

INDOOR HUMIDITY

80%* or below

4. INSTALLATION SITE

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

Operation procedure
<FUQ>
    Read the operation manual attached to the 

remote controller.

<FXUQ>
    Read the operation manual attached to the out-

door unit.

Operating procedure varies with heat pump type 
and cooling only type. Contact your Daikin dealer 
to confirm your system type.

To protect the unit, turn on the main power switch 
6 hours before operation.

If the main power supply is turned off during oper-
ation, operation will restart automatically after the 
power turns back on again.

AIR FLOW DIRECTION ADJUST

Press the AIR FLOW DIRECTION button to adjust 
the air flow angle.

5. OPERATION PROCEDURE

Up and down adjustment

Summary of Contents for FUQ71BUV1B x 2

Page 1: ...UAL MODELS Ceiling suspended Cassette type FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 English Deutsch Fran...

Page 2: ...dicionador de aire Dicho manual le indicar c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consulte el m...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling pr...

Page 5: ...indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire...

Page 6: ...signated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete install...

Page 7: ...if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leave...

Page 8: ...20 to 15 5 INDOOR TEMPERATURE D B 21 to 32 D B 15 to 27 W B 14 to 25 INDOOR HUMIDITY 80 or below 4 INSTALLATION SITE Pay attention to running noises too Are the following places selected a A place tha...

Page 9: ...gher than the set temperature At defrost oper ation 6 OPTIMUM OPERATION swing Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on...

Page 10: ...W TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral detergent When the flap is extremely contaminated remove it as below and clean...

Page 11: ...roller will vanish when the main power switch is turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to MAINTENANCE The follow...

Page 12: ...tion This continues temporary I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person 9 TRO...

Page 13: ...ified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to the operation manual attached to the remote controller If the FAN SPEED button is set t...

Page 14: ...3P177429 2D EM03A094F 0704 FS HT...

Reviews: