background image

7

English

1. Open the suction grille.

Slide both knobs simultaneously as shown and 
then pull them downward.
(Do the same procedure for closing.) 

(Refer to Fig. 1)

2. Remove the air filter.

Pull both knobs on the air filter up and out 
towards you. 

(Refer to Fig. 2)

3. Clean the air filter.

Use vacuum cleaner 

A)

 or 

wash the air filter with water

 B).

A)

Using a vacuum cleaner

B)

Washing with water

When the air filter is very dirty, 
use soft brush and 
neutral detergent.

Remove water and dry in the 
shade.

NOTE

Do not wash the air conditioner with hot water of 
more than 50°C, as doing so may result in discol-
oration and/or deformation.

Do not expose it to fire, as doing so may result in 
burning.

4. Fix the air filter

1

Slide the air filter along the suction grille’s 
frame and push it into the protruding section of 
the suction grille.

2

Lock the air filter in place by pushing down on 
the knobs.

 (Refer to Fig. 3)

Fig. 1

Fig. 2

Fig. 3

5. Close the suction grille.

Refer to item No. 1.

6. After turning on the power, press AIR FILTER 

CLEANING TIME ICON RESET button.

The display “

” vanishes.

HOW TO CLEAN AIR OUTLET AND OUTSIDE 
PANELS

Clean with soft cloth.

When it is difficult to remove stains, use water or 
neutral detergent.

When the flap is extremely contaminated, remove 
it as below and clean or exchange it.
(Flap for exchange is optional)

NOTE

Do not use gasoline, benzene, thinner, polishing 
powder, liquid insecticide. It may cause discolor-
ing or warping.

Do not let the indoor unit get wet. It may cause an 
electric shock or a fire.

Do not scrub firmly when washing the blade with 
water.
The surface sealing may peel off.

Do not use water or air of 50°C or higher for clean-
ing air filters and outside panels.

HOW TO CLEAN THE SUCTION GRILLE

1. Open the suction grille.

Refer to “HOW TO CLEAN THE AIR FILTER”

(Refer to Fig. 1)

2. Detach the suction grille.

1

Detach the two strings attaching the suction 
grille to the indoor unit.

2

With the suction grille in the open position, 
remove the suction grille by pushing it up as 
shown.

 (Refer to Fig. 4)

3. Remove the air filter

Refer to “HOW TO CLEAN THE AIR FILTER”.

4. Clean the suction grille.

Wash with a soft bristle brush 
and neutral detergent or 
water, and dry throughly.
• 

When very grimy

Directly apply the type of detergent used for 
cleaning ventilation fans or ovens, wait 10 min-
utes, and then rinse with water.

Fig. 4

Summary of Contents for FUQ71BUV1B x 2

Page 1: ...UAL MODELS Ceiling suspended Cassette type FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 English Deutsch Fran...

Page 2: ...dicionador de aire Dicho manual le indicar c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consulte el m...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling pr...

Page 5: ...indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire...

Page 6: ...signated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete install...

Page 7: ...if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leave...

Page 8: ...20 to 15 5 INDOOR TEMPERATURE D B 21 to 32 D B 15 to 27 W B 14 to 25 INDOOR HUMIDITY 80 or below 4 INSTALLATION SITE Pay attention to running noises too Are the following places selected a A place tha...

Page 9: ...gher than the set temperature At defrost oper ation 6 OPTIMUM OPERATION swing Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on...

Page 10: ...W TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral detergent When the flap is extremely contaminated remove it as below and clean...

Page 11: ...roller will vanish when the main power switch is turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to MAINTENANCE The follow...

Page 12: ...tion This continues temporary I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person 9 TRO...

Page 13: ...ified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to the operation manual attached to the remote controller If the FAN SPEED button is set t...

Page 14: ...3P177429 2D EM03A094F 0704 FS HT...