background image

English

4

Do not place items that might be damaged by 
water under the indoor unit.

Water may condensate and drip if the humidity 
reaches 80% or if the drain exit gets clogged.

Do not place a burner or heater at a place 
directly exposed to the wind from the air con-
ditioner.

Incomplete combustion of the burner or heater 
may result.

Do not allow a child to mount on the outdoor 
unit or avoid placing any object on it.

Falling or tumbling may result in injury.

Do not expose animals and plants directly to 
the wind.

Adverse influence to animals and plants may 
result.

Do not wash the air conditioner with water.

Electric shock or fire may result.

Do not install the air conditioner at any place 
where flammable gas may leak out.

If the gas leaks out and stays around the air con-
ditioner, a fire may break out.

Execute complete drain piping for perfect 
drainage.

Incomplete piping may result in a water leakage.

The appliance is not intended for use by young 
children or infirm persons without supervi-
sion.
Young children should be supervised to 
ensure that they do not play with the appli-
ance.
Consult with installation contractor for clean-
ing the inside of the air conditioner.

Wrong cleaning may make the plastics parts bro-
ken or cause failure of water leakage or electric 
shock.

Do not touch the air inlet or aluminium fin of 
the air conditioner.

Otherwise, injury may be caused.

Do not start or stop operating the air condi-
tioner with the power supply breaker turned 
ON or OFF.

Otherwise, fire or water leakage may result.
Furthermore, the fan will rotate abruptly if power 
failure compensation is enabled, which may result 
in injury.

Do not place objects in direct proximity of the 
outdoor unit and do not let leaves and other 
debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fire when making 
contact with electrical parts.

Never touch the internal parts of the remote 
controller.

Do not remove the front panel. Some parts inside 
are dangerous to touch, and a machine trouble 
may happen.
For checking and adjusting the internal parts, con-
tact your dealer.

Avoid placing the remote controller in a spot 
splashed with water.

Water coming inside the machine may cause an 
electric leak or may damage the internal electronic 
parts.

Watch your steps at the time of air filter clean-
ing or inspection.

High-place work is required, to which utmost 
attention must be paid. If the scaffold is unstable, 
you may fall or topple down, thus causing injury.

3-1. FUQ

If the temperature or the humidity is beyond the fol-
lowing conditions, safety devices may work and the 
air conditioner may not operate, or sometimes, 
water may drop from the indoor unit.
COOLING

HEATING

D

 

B: Dry bulb temperature (

°

C)

WB: Wet bulb temperature (

°

C)

The setting temperature range of the remote con-
troller is 16°C to 32°C.

3. OPERATION RANGE

OUTDOOR 

UNIT

INDOOR

OUTDOOR 

TEMPERA-

TURE

TEMPERA-

TURE

HUMID-

ITY

RZQ71, 100, 

125, 140

D

B

18 to 37

80% or 

below

D

B

–15 to 50

W

B

12 to 28

RQ71,100,125

D

B

18 to 37

80% or 

below

D

B

–5 to 46

W

B

12 to 28

RR71,100,125

D

B

18 to 37

80% or 

below

D

B

–15 to 46

W

B

12 to 28

OUTDOOR 

UNIT

INDOOR 

TEMPERATURE

OUTDOOR 

TEMPERATURE

RZQ71, 100, 

125, 140

D

B

10 to 27

D

B

–19.5 to 21

W

B

–20 to 15.5

RQ71,100,125

D

B

10 to 27

D

B

–9 to 21

W

B

–10 to 15

Summary of Contents for FUQ71BUV1B x 2

Page 1: ...UAL MODELS Ceiling suspended Cassette type FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 English Deutsch Fran...

Page 2: ...dicionador de aire Dicho manual le indicar c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consulte el m...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling pr...

Page 5: ...indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire...

Page 6: ...signated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete install...

Page 7: ...if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leave...

Page 8: ...20 to 15 5 INDOOR TEMPERATURE D B 21 to 32 D B 15 to 27 W B 14 to 25 INDOOR HUMIDITY 80 or below 4 INSTALLATION SITE Pay attention to running noises too Are the following places selected a A place tha...

Page 9: ...gher than the set temperature At defrost oper ation 6 OPTIMUM OPERATION swing Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on...

Page 10: ...W TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral detergent When the flap is extremely contaminated remove it as below and clean...

Page 11: ...roller will vanish when the main power switch is turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to MAINTENANCE The follow...

Page 12: ...tion This continues temporary I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person 9 TRO...

Page 13: ...ified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to the operation manual attached to the remote controller If the FAN SPEED button is set t...

Page 14: ...3P177429 2D EM03A094F 0704 FS HT...

Reviews: