• The precautions described below are WARN-

ING and CAUTION. These are very important 
precautions concerning safety. Be sure to 
observe all of them without fail.

WARNING

...These are the matters with possi-

bilities leading to serious conse-
quences such as death or serious 
injury due to erroneous handling.

CAUTION

....These are the matters with possi-

bilities leading to injury or material 
damage due to erroneous han-
dling including probabilities lead-
ing to serious consequences in 
some cases.

• After reading, keep this manual at a place 

where any user can read at any time. Further-
more, make certain that this operation manual 
is handed to a new user when he takes over 
the operation.

WARNING

Avoid exposure of your body directly to the 
cold air for a long time, or avoid excessive 
exposure of your body to the cold air.

Otherwise, your physical condition may be deteri-
orated and/or your health may be ruined.

When the air conditioner is in abnormal condi-
tions (smell of something burning, etc), unplug 
the power cord from the outlet, and contact the 
dealer where you purchased the air conditioner.

Continued operation under such circumstances 
may result in a failure, electric shock, and fire.

Ask your dealer for installation of the air con-
ditioner.

Incomplete installation performed by yourself may 
result in a water leakage, electric shock, and fire.

Ask your dealer for improvement, repair, and 
maintenance.

Incomplete improvement, repair, and maintenance 
may result in a water leakage, electric shock, and 
fire.

Do not insert your finger, a stick, etc., into the 
air inlet, outlet, and fan blades.

A fan in high-speed running may result in injury.

For refrigerant leakage, consult your dealer.

When the air conditioner is to be installed in a 
small room, it is necessary to take proper mea-
sures so that the amount of any leaked refrigerant 
does not exceed the limiting concentration even 
when it leaks. If the refrigerant leaks exceeding the 
level of limiting concentration, an oxygen defi-
ciency accident may happen.

For installation of separately sold component 
parts, ask a specialist.

Be sure to use the separately sold component 
parts designated by our company.
Incomplete installation performed by yourself may 
result in a water leakage, electric shock, and fire.

Ask your dealer to move and reinstall the air 
conditioner.

Incomplete installation may result in a water leak-
age, electric shock, and fire.

Do not use any fuse with improper capacity.

The use of a piece of wire and whatnot may result 
in a failure and fire.

The refrigerant in the air conditioner is safe 
and normally does not leak.
If the refrigerant leaks inside the room, the 
contact with a fire of a burner, a heater or a 
cooker may result in a harmful gas.

Do not use the air conditioner until when a service 
person confirms to finish repairing the portion 
where the refrigerant leaks.

Be sure to establish an earth.
Do not earth the unit to a utility pipe, arrester, 
or telephone earth.

Incomplete earth may cause electrical shock, or 
fire.
A high surge current from lightning or other 
sources may cause damage to the air conditioner.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may 
result in electric shocks, or fire.

Consult the dealer if the air conditioner sub-
merges owing to a natural disaster, such as a 
flood or typhoon.

Do not operate the air conditioner in that case, or 
otherwise a malfunction, electric shock, or fire 
may result.

CAUTION

Do not use the air conditioner for other pur-
poses.

Do not use the air conditioner for a special appli-
cation such as the storage of foods, animals and 
plants, precision machines, and art objects as oth-
erwise the deterioration of quality may result.

Do not remove the air outlet of the outdoor unit.

The fan may get exposed and result in injury.

When the air conditioner is used in combina-
tion with burners or heaters, perform sufficient 
ventilation.

Insufficient ventilation may result in an oxygen 
deficiency accident.

Check and make sure that foundation blocks 
are not damaged after a long use.

If they are left in a damaged condition, the unit 
may fall or tumble and result in injury.

Neither place a flammable spray bottle near 
the air conditioner nor perform spraying.

Doing so may result in a fire.

To clean the air conditioner, stop operation, 
and unplug the power cord from the outlet.

Otherwise, an electric shock and injury may result.

Do not operate the air conditioner with a wet 
hand.

An electric shock may result.

Summary of Contents for FUQ71BUV1B x 2

Page 1: ...UAL MODELS Ceiling suspended Cassette type FUQ71BUV1B FXUQ71MV1 FUQ71BVV1B FXUQ71MAV1 FUQ100BUV1B FXUQ100MV1 FUQ100BVV1B FXUQ100MAV1 FUQ125BUV1B FXUQ125MV1 FUQ125BVV1B FXUQ125MAV1 English Deutsch Fran...

Page 2: ...dicionador de aire Dicho manual le indicar c mo utilizar adecuadamente la m quina y le ayudar en caso de aver a Despu s de leer el manual cons rvelo para consultas futuras Funcionamiento consulte el m...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling pr...

Page 5: ...indoor units The unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire...

Page 6: ...signated by our company Incomplete installation performed by yourself may result in a water leakage electric shock and fire Ask your dealer to move and reinstall the air conditioner Incomplete install...

Page 7: ...if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Leave...

Page 8: ...20 to 15 5 INDOOR TEMPERATURE D B 21 to 32 D B 15 to 27 W B 14 to 25 INDOOR HUMIDITY 80 or below 4 INSTALLATION SITE Pay attention to running noises too Are the following places selected a A place tha...

Page 9: ...gher than the set temperature At defrost oper ation 6 OPTIMUM OPERATION swing Turn off the main power supply switch when it is not used for long periods of time When the main power switch is turned on...

Page 10: ...W TO CLEAN AIR OUTLET AND OUTSIDE PANELS Clean with soft cloth When it is difficult to remove stains use water or neutral detergent When the flap is extremely contaminated remove it as below and clean...

Page 11: ...roller will vanish when the main power switch is turned off Clean the air filter and the exterior Be sure to replace the air filter to its original place after cleaning Refer to MAINTENANCE The follow...

Page 12: ...tion This continues temporary I If one of the following malfunctions occurs take the measures shown below and contact your Daikin dealer The system must be repaired by a qualified service person 9 TRO...

Page 13: ...ified service person to clean the air filters Refer to MAINTENANCE If the set temperature is not proper Refer to the operation manual attached to the remote controller If the FAN SPEED button is set t...

Page 14: ...3P177429 2D EM03A094F 0704 FS HT...