Regarding places for installation

• Is the air conditioner installed at a well-ventilated 

place where there are no obstacles around?

• Do not use the air conditioner in the following 

places.

a. Filled with much mineral oil such as cutting oil
b. Where there is much salt such as a beach area
c. Where sulfured gas exists such as a hot-spring 

resort

d. Where there are considerable voltage fluctua-

tions such as a factory or plant

e. Vehicles and vessels
 f . Where there is much spray of oil and vapor 

such as a cookery, etc.

g. Where there are machines generating electro-

magnetic waves

h. Filled  with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer.

Regarding wiring

• All wiring must be performed by an authorized 

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit 

is provided for this air conditioner and that all 
electrical work is carried out by qualified per-
sonnel according to local laws and regulations.

Pay attention to running noises, too

• Are the following places selected?

a. A place that can sufficiently withstand the 

weight of the air conditioner with less running 
noises and vibrations.

b. A place where the hot wind discharged from the 

air outlet of the outdoor unit and the running 
noises.

• Are you sure that there are no obstacles near 

the air outlet of the outdoor unit?

Such obstacles may result in declined perfor-
mance and increased running noises.

• If abnormal noises occur in use, consult your 

dealer.

Regarding drainage of drain piping

• Is the drain piping executed to perform com-

plete drainage?

If proper drainage is not carried out from the out-
door drain pipes during air-conditioning operation, 
chances are that dust and dirt are clogged in the 
pipe. This may result in a water leakage from the 
indoor unit. Under such circumstances, stop the 
operation of the air conditioner, and then consult 
your dealer or our service station.

4. INSTALLATION SITE

Operation procedure
<FUQ>
    Read the operation manual attached to the 

remote controller.

<FXUQ>
    Read the operation manual attached to the out-

door unit.

Operating procedure varies with heat pump type 
and cooling only type. Contact your Daikin dealer 
to confirm your system type.

To protect the unit, turn on the main power switch 
6 hours before operation.

If the main power supply is turned off during oper-
ation, operation will restart automatically after the 
power turns back on again.

AIR FLOW DIRECTION ADJUST

Press the AIR FLOW DIRECTION button to adjust 
the air flow angle.

Press the AIR FLOW DIRECTION ADJUST but-
ton to select the air direction as shown below.

The AIR FLOW FLAP display 
swings as shown below and the air 
flow direction continuously varies. 
(Automatic swing setting)

Press AIR FLOW DIRECTION 
ADJUST button to select the air 
direction of your choice.

The AIR FLOW FLAP display 
stops swinging and the air flow 
direction is fixed (Fixed air flow 
direction setting).

MOVEMENT OF THE AIR FLOW FLAP

For the following conditions, micro computer con-
trols the air flow direction so it may be different from 
the display.

Operation mode includes automatic operation.

5. OPERATION PROCEDURE

Operation mode

Cooling

Heating

Operation 
condition

When room 
temperature 
is lower than 
the set tem-
perature

When room 
temperature is 
higher than the 
set temperature

At defrost oper-
ation

Up and down adjustment

swing

01_EN_3P170549-15K.fm  Page 6  Monday, January 16, 2012  3:07 PM

Summary of Contents for FUQ series

Page 1: ...Q71BVV1B FUQ71BWV1B FUQ100BUV1B FUQ100BVV1B FUQ100BWV1B FUQ125BUV1B FUQ125BVV1B FUQ125BWV1B FXUQ71MV1 FXUQ71MAV1 FXUQ100MV1 FXUQ100MAV1 FXUQ125MV1 FXUQ125MAV1 English Deutsch Français Español Italiano ΕλληνικÜ Nederlands Portugues Русский 00_CV_3P170549 15K_01 fm Page 1 Friday January 6 2012 5 06 PM ...

Page 2: ...e di ottenere un aiuto in caso di anomalia di funzionamento Dopo aver letto il manuale conservarlo in un luogo accessibile per una futura neces sità Funzionamento leggere il manuale d istruzioni del tele comando per informazioni dettagliate sui nomi e le funzi oni di interruttori e visualizzazioni sul telecomando Σαò ευχαριστοýìε που αγορÜσατε τη συσκευÞ κλιìατισìοý ÄιαβÜστε προσεκτικÜ αυτÝò τιò ο...

Page 3: ...ales para obtener más información Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normativa local y nacional aplicable Specifiche di smaltimento Il climatizzatore è contrassegnato con questo simbolo ciò significa che i pro dotti elettrici ed elettronici non possono essere smaltiti insieme ai rifiuti domestici non differenziati Non cercare di rimuovere il ...

Page 4: ... operation modes 1 WHAT TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling program dry and fan operation modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLERS CONTROL SYSTEM This system provides two other control systems beside individual...

Page 5: ...he unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire Wire to ground from the outdoor unit to prevent electrical shocks l Drain pumping out device built in Drains water removed from the room during cooling Outdoor unit Indoor unit Unit with remote controller Unit with ...

Page 6: ...ired Consult your local dealer regarding what to do in case of refrigerant leakage When the air conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion Contact professional personnel about atta...

Page 7: ...heat can cause deformation Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Be sure that children plants or animals are not exposed directly to airflow from the unit as adverse effects may ensue Do not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vas...

Page 8: ... or below D B 15 to 46 W B 12 to 28 RZQG71 100 125 140 D B 18 to 37 80 or below D B 15 to 50 W B 12 to 28 HEATING D B Dry bulb temperature C WB Wet bulb temperature C The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes wate...

Page 9: ...inage If proper drainage is not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under such circumstances stop the operation of the air conditioner and then consult your dealer or our service station 4 INSTALLATION SITE Operation procedure FUQ Read the operation...

Page 10: ...ration Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE IMPORTANT BEFORE OBTAINING ACCESS TO TERMINAL DEVICES ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED To clean the air conditioner be sure to stop oper ation and turn the power switch off Otherwise an electric shock and injury may result 6 OPTIMUM OPERATION 7 MAINTENANCE FOR SERVICE ...

Page 11: ...THE AIR FILTER Refer to Fig 1 2 Detach the suction grille 1 Detach the two strings attaching the suction grille to the indoor unit Fig 3 2 With the suction grille in the open position remove the suction grille by pushing it up as shown Refer to Fig 4 3 Remove the air filter Refer to HOW TO CLEAN THE AIR FILTER 4 Clean the suction grille Wash with a soft bristle brush and neutral detergent or water...

Page 12: ...mp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of the sys tem After 3 minutes the system will turn on again automatically The system does not start when the display shows and it flashes for few sec onds after pressing an operation button This is because the system is under centralized con trol Flashes on the display ...

Page 13: ...flash and the MALFUNCTION CODE appears Measure Notify your Daikin dealer and inform him her of the display II If the system does not properly operate except for the above mentioned case and none of the above mentioned malfunctions is evident investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is res...

Page 14: ...ECTION ADJUST If the doors or the windows are open Shut doors or windows to prevent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large If the heat source of the room is excessive when cooling Cooling effect decreases if heat gain of the...

Page 15: ...3P170549 15K EM11A074 1201 HT 00_CV_3P170549 15K_01 fm Page 2 Friday January 6 2012 5 06 PM ...