START UP AFTER A LONG STOP

Confirm the following

Check that the air inlet and outlet are not blocked.
Remove any obstacle.

Check if the earth is connected.
Might there be a broken wire somewhere?
Contact your dealer if there are any problems.

Clean the air filter and outside panels

After cleaning the air filter, make sure to attach it.

Turn on the main power supply switch

The display on the remote controller will be shown 
when the power is turned on.

To protect the unit, turn on the main power switch 
at least 6 hours before operation.

WHAT TO DO WHEN STOPPING THE SYS-
TEM FOR A LONG PERIOD

Turn on FAN OPERATION for a half day and dry 
the unit.

Read the operation manual attached to the 
remote controller.

Cut off the power supply.

When the main power switch is turned on, some 
watts of electricity is being used even if the sys-
tem is not operating.
Turn off the main power supply switch for saving 
energy.

The display on the remote controller will vanish 
when the main power switch is turned off. 

Clean the air filter and the exterior.

Be sure to replace the air filter to its original place 
after cleaning. Refer to “MAINTENANCE”.

The following symptoms do not indicate air condi-
tioner malfunction

I. THE SYSTEM DOES NOT OPERATE

• The system does not restart immediately after 

the ON/OFF button is pressed.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again 
automatically.

8. NOT MALFUNCTION OF THE 

AIR CONDITIONER

• The system does not restart immediately when 

TEMPERATURE SETTING button is returned to 
the former position after pushing the button.

If the OPERATION lamp lights, the system is in 
normal condition.
It does not restart immediately because a safety 
device operates to prevent overload of the sys-
tem. After 3 minutes, the system will turn on again 
automatically.

• The system does not start when the display 

shows “

” and it flashes for few sec-

onds after pressing an operation button.

This is because the system is under centralized con-
trol. Flashes on the display indicates that the system 
cannot be controlled by the remote controller.

• The system does not start immediately after 

the power supply is turned on.

Wait one minute until the micro computer is pre-
pared for operation.

II. WHITE MIST COMES OUT OF A UNIT

• When humidity is high during cooling opera-

tion (In oily or dusty places)

If the inside of an indoor unit is extremely contam-
inated, the temperature distribution inside a room 
becomes uneven. It is necessary to clean the 
inside of the indoor unit. Ask your Daikin dealer for 
details on cleaning the unit. This operation 
requires a qualified service person.

• When the system is changed over to HEATING 

OPERATION after DEFROST OPERATION.

Moisture generated by DEFROST becomes 
steam and exists.

III. NOISE OF AIR CONDITIONERS

• A ringing sound after the unit is started.

This sound is generated by the temperature regu-
lator working.
It will quiet down after about a minute.

• A continuous flow “Shuh” sound is heard 

when the systems is in COOLING or DEFROST 
OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• A “Shuh” sound which is heard at the start or 

immediately after the stop of operation or 
which is heard at the start or immediately after 
the stop of DEFROST OPERATION. 

This is the noise of refrigerant caused by flow stop 
and flow change.

• A continuous low “Shah” sound is heard 

when the system is in COOLING OPERATION 
or at a stop.

The noise is heard when the drain pump is in 
operation.

01_EN_3P170549-15K.fm  Page 9  Monday, January 16, 2012  3:07 PM

Summary of Contents for FUQ series

Page 1: ...Q71BVV1B FUQ71BWV1B FUQ100BUV1B FUQ100BVV1B FUQ100BWV1B FUQ125BUV1B FUQ125BVV1B FUQ125BWV1B FXUQ71MV1 FXUQ71MAV1 FXUQ100MV1 FXUQ100MAV1 FXUQ125MV1 FXUQ125MAV1 English Deutsch Français Español Italiano ΕλληνικÜ Nederlands Portugues Русский 00_CV_3P170549 15K_01 fm Page 1 Friday January 6 2012 5 06 PM ...

Page 2: ...e di ottenere un aiuto in caso di anomalia di funzionamento Dopo aver letto il manuale conservarlo in un luogo accessibile per una futura neces sità Funzionamento leggere il manuale d istruzioni del tele comando per informazioni dettagliate sui nomi e le funzi oni di interruttori e visualizzazioni sul telecomando Σαò ευχαριστοýìε που αγορÜσατε τη συσκευÞ κλιìατισìοý ÄιαβÜστε προσεκτικÜ αυτÝò τιò ο...

Page 3: ...ales para obtener más información Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normativa local y nacional aplicable Specifiche di smaltimento Il climatizzatore è contrassegnato con questo simbolo ciò significa che i pro dotti elettrici ed elettronici non possono essere smaltiti insieme ai rifiuti domestici non differenziati Non cercare di rimuovere il ...

Page 4: ... operation modes 1 WHAT TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling program dry and fan operation modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLERS CONTROL SYSTEM This system provides two other control systems beside individual...

Page 5: ...he unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire Wire to ground from the outdoor unit to prevent electrical shocks l Drain pumping out device built in Drains water removed from the room during cooling Outdoor unit Indoor unit Unit with remote controller Unit with ...

Page 6: ...ired Consult your local dealer regarding what to do in case of refrigerant leakage When the air conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion Contact professional personnel about atta...

Page 7: ...heat can cause deformation Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Be sure that children plants or animals are not exposed directly to airflow from the unit as adverse effects may ensue Do not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vas...

Page 8: ... or below D B 15 to 46 W B 12 to 28 RZQG71 100 125 140 D B 18 to 37 80 or below D B 15 to 50 W B 12 to 28 HEATING D B Dry bulb temperature C WB Wet bulb temperature C The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes wate...

Page 9: ...inage If proper drainage is not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under such circumstances stop the operation of the air conditioner and then consult your dealer or our service station 4 INSTALLATION SITE Operation procedure FUQ Read the operation...

Page 10: ...ration Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE IMPORTANT BEFORE OBTAINING ACCESS TO TERMINAL DEVICES ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED To clean the air conditioner be sure to stop oper ation and turn the power switch off Otherwise an electric shock and injury may result 6 OPTIMUM OPERATION 7 MAINTENANCE FOR SERVICE ...

Page 11: ...THE AIR FILTER Refer to Fig 1 2 Detach the suction grille 1 Detach the two strings attaching the suction grille to the indoor unit Fig 3 2 With the suction grille in the open position remove the suction grille by pushing it up as shown Refer to Fig 4 3 Remove the air filter Refer to HOW TO CLEAN THE AIR FILTER 4 Clean the suction grille Wash with a soft bristle brush and neutral detergent or water...

Page 12: ...mp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of the sys tem After 3 minutes the system will turn on again automatically The system does not start when the display shows and it flashes for few sec onds after pressing an operation button This is because the system is under centralized con trol Flashes on the display ...

Page 13: ...flash and the MALFUNCTION CODE appears Measure Notify your Daikin dealer and inform him her of the display II If the system does not properly operate except for the above mentioned case and none of the above mentioned malfunctions is evident investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is res...

Page 14: ...ECTION ADJUST If the doors or the windows are open Shut doors or windows to prevent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large If the heat source of the room is excessive when cooling Cooling effect decreases if heat gain of the...

Page 15: ...3P170549 15K EM11A074 1201 HT 00_CV_3P170549 15K_01 fm Page 2 Friday January 6 2012 5 06 PM ...

Reviews: