background image

English

4

Do not use flammable materials (e.g., hair-
spray or insecticide) near the product.
Do not clean the product with organic sol-
vents such as paint thinner.

The use of organic solvents may cause crack 
damage to the product, electric shocks, or fire.

Be sure to use a dedicated power supply for 
the air conditioner.

The use of any other power supply may cause 
heat generation, fire, or product failures.

Consult your dealer regarding cleaning the 
inside of the air conditioner.

Improper cleaning may cause breakage of plas-
tic parts, water leakage and other damage as 
well as electric shocks.

CAUTION

Do not use the air conditioner for purposes 
other than those for which it is intended.

Do not use the air conditioner for cooling precision 
instruments, food, plants, animals or works of art 
as this may adversely affect the performance, 
quality and/or longevity of the object concerned.

Do not remove the outdoor unit’s fan guard.

The guard protects against the unit’s high speed 
fan, which may cause injury.

To avoid oxygen deficiency, ensure that the 
room is adequately ventilated if equipment 
such as a burner is used together with the air 
conditioner.

Do not place flammable sprays or operate 
spray containers near the unit as this may 
result in fire.

Do not put flammable containers, such as 
spray cans, within 1 m from the air outlet.

The containers may explode because the warm 
air output of the indoor or outdoor unit will affect 
them.

Before cleaning, be sure to stop unit opera-
tion, turn the power circuit breaker off or 
remove the power cord.

Otherwise, an electric shock and injury may 
result.

To avoid electric shocks, do not operate with 
wet hands.

Do not place objects that are susceptible to 
moisture directly beneath the indoor or out-
door units.

Under certain conditions, condensation on the 
main unit or refrigerant pipes, air filter dirt or 
drain blockage may cause dripping, resulting in 
fouling or failure of the object concerned.

Do not place appliances that produce naked 
flames in places exposed to the airflow from 
the unit as this may impair combustion of the 
burner.

Do not place heaters directly below the unit, 
as resulting heat can cause deformation.

Do not allow a child to mount on the outdoor 
unit or avoid placing any object on it.

Falling or tumbling may result in injury.

Be sure that children, plants or animals are 
not exposed directly to airflow from the unit, 
as adverse effects may ensue.

Do not wash the air conditioner with water, 
as this may result in electric shocks or fire.

Do not place water containers (flower vases, 
etc.) on the unit, as this may result in electric 
shocks or fire.

Do not install the air conditioner at any place 
where there is a danger of flammable gas 
leakage.

In the event of a gas leakage, build-up of gas 
near the air conditioner may result in fire hazards.

Carry out drain piping properly to ensure 
complete drainage.

If drain piping is not carried out properly, drain 
will not flow out. Then, dirt and debris may be 
accumulated in the drain pipe and may cause 
water leakage. If it occurs, stop the air condi-
tioner and call your dealer for assistance.

The appliance is not intended for use by unat-
tended young children or persons who are 
incompetent to operate air conditioners.

It may result in injury or electric shock.

Children should be watched so that they do 
not play with the unit or its remote controller.

Accidental operation by a child may result in 
injury or electric shock.

To avoid injury, do not touch the air inlet or 
aluminum fins of the unit.

Do not place objects in direct proximity of the 
outdoor unit and do not let leaves and other 
debris accumulate around the unit.

Leaves are a hotbed for small animals which can 
enter the unit. Once in the unit, such animals can 
cause malfunctions, smoke or fire when making 
contact with electrical parts.

Do not block air inlets nor outlets.

Impaired airflow may result in insufficient perfor-
mance or trouble.

Do not let children play on or around the out-
door unit.

If they touch the unit carelessly, injury may be 
caused.

Turn off the power when the unit is not to be 
used for long periods of time.

Otherwise, the unit may get hot or catch on fire 
due to dust accumulation.

Never touch the internal parts of the remote 
controller.

Do not remove the front panel. Touching certain 
internal parts will cause electric shocks and 
damage to the unit. Please consult your dealer 
about checking and adjustment of internal parts.

01_EN_3P170549-15K.fm  Page 4  Monday, January 16, 2012  3:07 PM

Summary of Contents for FUQ series

Page 1: ...Q71BVV1B FUQ71BWV1B FUQ100BUV1B FUQ100BVV1B FUQ100BWV1B FUQ125BUV1B FUQ125BVV1B FUQ125BWV1B FXUQ71MV1 FXUQ71MAV1 FXUQ100MV1 FXUQ100MAV1 FXUQ125MV1 FXUQ125MAV1 English Deutsch Français Español Italiano ΕλληνικÜ Nederlands Portugues Русский 00_CV_3P170549 15K_01 fm Page 1 Friday January 6 2012 5 06 PM ...

Page 2: ...e di ottenere un aiuto in caso di anomalia di funzionamento Dopo aver letto il manuale conservarlo in un luogo accessibile per una futura neces sità Funzionamento leggere il manuale d istruzioni del tele comando per informazioni dettagliate sui nomi e le funzi oni di interruttori e visualizzazioni sul telecomando Σαò ευχαριστοýìε που αγορÜσατε τη συσκευÞ κλιìατισìοý ÄιαβÜστε προσεκτικÜ αυτÝò τιò ο...

Page 3: ...ales para obtener más información Las pilas del control remoto deben extraerse y eliminarse por separado y de acuerdo con la normativa local y nacional aplicable Specifiche di smaltimento Il climatizzatore è contrassegnato con questo simbolo ciò significa che i pro dotti elettrici ed elettronici non possono essere smaltiti insieme ai rifiuti domestici non differenziati Non cercare di rimuovere il ...

Page 4: ... operation modes 1 WHAT TO DO BEFORE OPERA TION Outdoor unit Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Cooling only type This system provides cooling program dry and fan operation modes PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLERS CONTROL SYSTEM This system provides two other control systems beside individual...

Page 5: ...he unit is individually operated NOTE Contact your Daikin dealer in case of changing the combination or setting of group control and two remote controller control systems k Ground wire Wire to ground from the outdoor unit to prevent electrical shocks l Drain pumping out device built in Drains water removed from the room during cooling Outdoor unit Indoor unit Unit with remote controller Unit with ...

Page 6: ...ired Consult your local dealer regarding what to do in case of refrigerant leakage When the air conditioner is to be installed in a small room it is necessary to take proper mea sures so that the amount of any leaked refriger ant does not exceed the concentration limit in the event of a leakage Otherwise this may lead to an accident due to oxygen depletion Contact professional personnel about atta...

Page 7: ...heat can cause deformation Do not allow a child to mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Be sure that children plants or animals are not exposed directly to airflow from the unit as adverse effects may ensue Do not wash the air conditioner with water as this may result in electric shocks or fire Do not place water containers flower vas...

Page 8: ... or below D B 15 to 46 W B 12 to 28 RZQG71 100 125 140 D B 18 to 37 80 or below D B 15 to 50 W B 12 to 28 HEATING D B Dry bulb temperature C WB Wet bulb temperature C The setting temperature range of the remote con troller is 16 C to 32 C 3 2 FXUQ If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes wate...

Page 9: ...inage If proper drainage is not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under such circumstances stop the operation of the air conditioner and then consult your dealer or our service station 4 INSTALLATION SITE Operation procedure FUQ Read the operation...

Page 10: ...ration Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS ALLOWED TO PERFORM MAINTENANCE IMPORTANT BEFORE OBTAINING ACCESS TO TERMINAL DEVICES ALL POWER SUPPLY CIRCUITS MUST BE INTERRUPTED To clean the air conditioner be sure to stop oper ation and turn the power switch off Otherwise an electric shock and injury may result 6 OPTIMUM OPERATION 7 MAINTENANCE FOR SERVICE ...

Page 11: ...THE AIR FILTER Refer to Fig 1 2 Detach the suction grille 1 Detach the two strings attaching the suction grille to the indoor unit Fig 3 2 With the suction grille in the open position remove the suction grille by pushing it up as shown Refer to Fig 4 3 Remove the air filter Refer to HOW TO CLEAN THE AIR FILTER 4 Clean the suction grille Wash with a soft bristle brush and neutral detergent or water...

Page 12: ...mp lights the system is in normal condition It does not restart immediately because a safety device operates to prevent overload of the sys tem After 3 minutes the system will turn on again automatically The system does not start when the display shows and it flashes for few sec onds after pressing an operation button This is because the system is under centralized con trol Flashes on the display ...

Page 13: ...flash and the MALFUNCTION CODE appears Measure Notify your Daikin dealer and inform him her of the display II If the system does not properly operate except for the above mentioned case and none of the above mentioned malfunctions is evident investigate the system according to the following procedures 1 If the system does not operate at all Check if there is a power failure Wait until power is res...

Page 14: ...ECTION ADJUST If the doors or the windows are open Shut doors or windows to prevent wind from coming in If direct sunlight enters the room when cooling Use curtains or blinds When there are too many inhabitants in the room when cooling Cooling effect decreases if heat gain of the room is too large If the heat source of the room is excessive when cooling Cooling effect decreases if heat gain of the...

Page 15: ...3P170549 15K EM11A074 1201 HT 00_CV_3P170549 15K_01 fm Page 2 Friday January 6 2012 5 06 PM ...

Reviews: