background image

7 Maintenance and service

Operation manual

15

FTXTA30B2V1B(W)(B)
Daikin room air conditioner
3P485919-13U – 2021.03

7

Maintenance and service

7.1

Overview: Maintenance and
service

The installer has to perform a yearly maintenance.

About the refrigerant

This  product  contains  fluorinated  greenhouse  gases.  Do  NOT  vent
gases into the atmosphere.

Refrigerant type: R32

Global warming potential (GWP) value: 675

NOTICE

Applicable  legislation  on 

fluorinated  greenhouse  gases

requires  that  the  refrigerant  charge  of  the  unit  is  indicated
both in weight and CO

2

 equivalent.

Formula  to  calculate  the  quantity  in  CO

2

  equivalent

tonnes:

  GWP  value  of  the  refrigerant  ×  total  refrigerant

charge [in kg] / 1000

Please contact your installer for more information.

WARNING

The  refrigerant  inside  the  unit  is  mildly  flammable,  but
normally  does  NOT  leak.  If  the  refrigerant  leaks  in  the
room  and  comes  in  contact  with  fire  from  a  burner,  a
heater, or a cooker, this may result in fire, or the formation
of a harmful gas.

Turn  off  any  combustible  heating  devices,  ventilate  the
room,  and  contact  the  dealer  where  you  purchased  the
unit.

Do  NOT  use  the  unit  until  a  service  person  confirms  that
the  part  from  which  the  refrigerant  leaked  has  been
repaired.

WARNING

▪ Do NOT pierce or burn refrigerant cycle parts.

▪ Do NOT use cleaning materials or means to accelerate

the  defrosting  process  other  than  those  recommended
by the manufacturer.

▪ Be  aware  that  the  refrigerant  inside  the  system  is

odourless.

WARNING

The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating  ignition  sources  (e.g.  open  flames,  an  operating
gas  appliance,  or  an  operating  electric  heater).  The  room
size shall be as specified in the General safety precaution.

NOTICE

Maintenance  MUST  be  done  by  an  authorized  installer  or
service agent.

We  recommend  performing  maintenance  at  least  once  a
year. However, applicable legislation might require shorter
maintenance intervals.

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electrical shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be careful with ladders when working in high places.

7.2

To clean the indoor unit and user
interface

WARNING

Improper  detergents  or  cleaning  procedure  may  cause
damage  on  plastic  components  or  water  leakage.
Splashed  detergent  on  electric  components,  such  as
motors, may cause failure, smoke or ignition.

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner,  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

▪ As an end user, you may NEVER clean inside parts of

the unit by yourself; this work must be performed by a
qualified service person. Contact your dealer.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

7.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

7.4

To open the front panel

Open the front panel using the user interface.

1

Stop operation.

2

Hold 

 on the user interface for at least 2 seconds.

Summary of Contents for FTXTA30B2V1BW

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTA30B2V1BW FTXTA30B2V1BB...

Page 2: ...m reservations 12 5 10 4 To deactivate and reactivate Weekly timer operation 12 5 10 5 To delete reservations 12 5 11 Wireless LAN connection 13 5 11 1 Precautions when using the wireless LAN 13 5 11...

Page 3: ...ers are swinging and you move them forcibly by hand the mechanism will break CAUTION NEVER expose little children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottl...

Page 4: ...ration distance between the radiating part of the equipment and the user is 10 cm NOTICE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for co...

Page 5: ...el push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode...

Page 6: ...o change the setting as follows is blinking Brightness is High Low Off 4 To confirm the selected setting press Result The brightness setting is changed Note The display automatically returns to the de...

Page 7: ...when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automati...

Page 8: ...airflow direction 1 Press and Result and appear on the LCD The flaps horizontal blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reac...

Page 9: ...owerful operation CANNOT be used together with Econo Comfort airflow Intelligent eye and Outdoor unit quiet operation The last selected function takes priority Powerful operation will NOT increase the...

Page 10: ...ce logic operation can be activated only in heating operation mode see 5 2 1 To start stop operation mode and to set the temperature 47 1 Press one or more times Result The setting will change as foll...

Page 11: ...C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operati...

Page 12: ...mplete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 411 5 10 3 To confirm reservations You can confirm...

Page 13: ...e Connect the wireless LAN to your smart device directly Connect the wireless LAN to your home network The wireless LAN will communicate with your smart device in your home network using a modem route...

Page 14: ...esult is blinking The setting is reset to the factory default 4 Press to exit the menu Result The display will return to the default screen To turn off the wireless LAN connection You can turn off the...

Page 15: ...performing maintenance at least once a year However applicable legislation might require shorter maintenance intervals DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure...

Page 16: ...deodorising filter and silver particle filter from the tabs 4 Wash the air filters with water or clean them with a vacuum cleaner 5 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If th...

Page 17: ...it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 415 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lightl...

Page 18: ...n OFF the power supply The operation lamp flashes and you can check the error code by the user interface To display the error code see the user reference guide Notify your installer and report the err...

Page 19: ......

Page 20: ...3P485919 13U 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: