background image

5 Operation

Operation manual

8

FTXTA30B2V1B(W)(B)

Daikin room air conditioner

3P485919-13U – 2021.03

5.4

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user  selection  (swinging  or  fixed  position).  It  does  so  by  moving
horizontal blades (flaps) or vertical blades (louvers).

Setting

Airflow direction

 Vertical automatic

swing

Moves up and down.

 Horizontal

automatic swing

Moves from side to side.

+

 3-D airflow

direction

Moves alternately up and down and
from side to side

[—]

Stays in a fixed position.

CAUTION

ALWAYS use a user interface to adjust the position of the
flaps and louvers. When the flaps and louvers are swinging
and  you  move  them  forcibly  by  hand,  the  mechanism  will
break.

The  movable  range  of  the  flap  varies  according  to  the  operation
mode. The flap will stop at the upper position when the airflow rate is
changed to low during the up and down swing setting.

5.4.1

To adjust vertical airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  flaps  (horizontal  blades)

will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flaps  reach  the

desired position.

Result: 

  disappears  from  the  LCD.  The  flaps  will  stop

moving.

5.4.2

To adjust horizontal airflow direction

1

Press 

.

Result: 

  appears  on  the  LCD.  The  louvers  (vertical

blades) will begin to swing.

2

To use fixed position, press 

 when the louvers reach the

desired position.

Result: 

  disappears  from  the  LCD.  The  louvers  will  stop

moving.

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

5.4.3

To use 3-D airflow direction

1

Press 

 and 

.

Result: 

 and 

 appear on the LCD. The flaps (horizontal

blades) and louvers (vertical blades) will begin to swing.

2

To use fixed position, press 

 and 

 when the flaps

and louvers reach the desired position.

Result: 

  and 

  disappear  from  the  LCD.  The  flaps  and

the louvers will stop moving.

5.5

Comfort airflow and Intelligent eye
operation

You  can  use  Comfort  and  Intelligent  eye  operation  separately,  or
combine them.

5.5.1

Comfort airflow operation

The unit will automatically change the direction of the airflow to heat
up  or  cool  down  the  room  more  effectively.  Direct  airflow  from  the
unit will be less noticeable.

a

b

c

a

Flap position in cooling and dry operation

b

Flap range in heating operation (vertical airflow ON)

c

Flap position in heating operation (vertical airflow OFF)

In cooling and drying

The airflow direction will change to spread the air along the ceiling.

Comfort airflow ON

Comfort airflow OFF

In heating

The  airflow  direction  will  change  to  spread  the  air  along  the  floor.
The  unit  detects  the  room  and  floor  temperature  and  automatically
selects 1 of the 3 airflow directions.

Warming up

Downward direction

Vertical airflow

direction

INFORMATION

If  you  want  to  deactivate  the  Vertical  airflow  function  (e.g.
in case there is furniture or another object under the unit),
refer  to 

"To  turn  ON/OFF  vertical  airflow  function"

  [

4

  8].  If

the  Vertical  airflow  function  is  deactivated,  the  airflow  will
be set to downward direction.

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If  the  vertical  automatic  swing  is  selected,  Comfort  airflow
operation will be cancelled.

To turn ON/OFF vertical airflow function

1

Press 

 for at least 2 seconds.

Result: 

The menu   appears on the display.

2

Press 

 or 

 to change the menu screen.

Result: 

The menu   appears on the display.

Summary of Contents for FTXTA30B2V1BW

Page 1: ...Operation manual Daikin room air conditioner English Operation manual Daikin room air conditioner FTXTA30B2V1BW FTXTA30B2V1BB...

Page 2: ...m reservations 12 5 10 4 To deactivate and reactivate Weekly timer operation 12 5 10 5 To delete reservations 12 5 11 Wireless LAN connection 13 5 11 1 Precautions when using the wireless LAN 13 5 11...

Page 3: ...ers are swinging and you move them forcibly by hand the mechanism will break CAUTION NEVER expose little children plants or animals directly to the airflow WARNING Do NOT place a flammable spray bottl...

Page 4: ...ration distance between the radiating part of the equipment and the user is 10 cm NOTICE Do NOT use the system for other purposes In order to avoid any quality deterioration do NOT use the unit for co...

Page 5: ...el push 2 seconds button j OFF ON timer operation buttons k Weekly timer operation buttons l Flash Streamer and Fireplace logic operation button m Econo and Outdoor unit quiet operation button n Mode...

Page 6: ...o change the setting as follows is blinking Brightness is High Low Off 4 To confirm the selected setting press Result The brightness setting is changed Note The display automatically returns to the de...

Page 7: ...when the outside temperature is too high or too low Defrost operation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automati...

Page 8: ...airflow direction 1 Press and Result and appear on the LCD The flaps horizontal blades and louvers vertical blades will begin to swing 2 To use fixed position press and when the flaps and louvers reac...

Page 9: ...owerful operation CANNOT be used together with Econo Comfort airflow Intelligent eye and Outdoor unit quiet operation The last selected function takes priority Powerful operation will NOT increase the...

Page 10: ...ce logic operation can be activated only in heating operation mode see 5 2 1 To start stop operation mode and to set the temperature 47 1 Press one or more times Result The setting will change as foll...

Page 11: ...C 25 C 22 00 1 2 3 4 ON OFF ON OFF Saturday No timer setting Sunday Make up to 4 settings 8 00 10 00 19 00 21 00 27 C 27 C 25 C ON OFF OFF ON 1 2 3 4 ON ON ON ON setting Enables scheduling the operati...

Page 12: ...mplete the setting Result is displayed on the LCD Note To change the reservation setting after copying refer to 5 10 1 To set Weekly timer operation 411 5 10 3 To confirm reservations You can confirm...

Page 13: ...e Connect the wireless LAN to your smart device directly Connect the wireless LAN to your home network The wireless LAN will communicate with your smart device in your home network using a modem route...

Page 14: ...esult is blinking The setting is reset to the factory default 4 Press to exit the menu Result The display will return to the default screen To turn off the wireless LAN connection You can turn off the...

Page 15: ...performing maintenance at least once a year However applicable legislation might require shorter maintenance intervals DANGER RISK OF ELECTROCUTION To clean the air conditioner or air filter be sure...

Page 16: ...deodorising filter and silver particle filter from the tabs 4 Wash the air filters with water or clean them with a vacuum cleaner 5 Soak in lukewarm water for about 10 to 15 minutes INFORMATION If th...

Page 17: ...it MUST be replaced 1 Open the front panel See 7 4 To open the front panel 415 2 Open the panel locks located on the back side of the panel 1 on each side a a a Panel lock 3 Push the right arm lightl...

Page 18: ...n OFF the power supply The operation lamp flashes and you can check the error code by the user interface To display the error code see the user reference guide Notify your installer and report the err...

Page 19: ......

Page 20: ...3P485919 13U 2021 03 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: