background image

Table of Contents

Operation manual

2

FTXP20~71L2V1B

R32 split series

3P511999-1C – 2018.01

Table of Contents

1 About the documentation

2

1.1

About this document..................................................................

2

2 About the system

2

2.1

Indoor unit .................................................................................

2

2.2

About the user interface ............................................................

3

2.2.1

Components: User interface .......................................

3

2.2.2

Status: User interface LCD .........................................

3

2.2.3

To operate the user interface......................................

4

3 Before operation

4

3.1

To fix the user interface to the wall............................................

4

3.2

To insert the batteries................................................................

4

3.3

To switch between Fahrenheit and Celsius...............................

4

3.4

To turn on the power supply......................................................

4

4 Operation

4

4.1

Operation range ........................................................................

4

4.2

When to use which feature........................................................

5

4.3

Operation mode and temperature setpoint................................

5

4.3.1

To start/stop operation and to set the temperature.....

5

4.3.2

Airflow rate ..................................................................

5

4.3.3

Airflow direction...........................................................

6

4.3.4

Comfort airflow operation............................................

6

4.3.5

Powerful operation ......................................................

6

4.3.6

Econo operation..........................................................

7

4.3.7

OFF/ON timer operation .............................................

7

5 Energy saving and optimum operation

8

6 Maintenance and service

8

6.1

Overview: Maintenance and service .........................................

8

6.2

To clean the indoor unit and user interface ...............................

9

6.3

To clean the front panel.............................................................

9

6.4

To open the front panel .............................................................

9

6.5

To clean the air filters ................................................................

9

6.6

To clean the titanium apatite deodorizing filter..........................

10

6.7

To replace the titanium apatite deodorizing filter.......................

10

6.8

To close the front panel.............................................................

10

6.9

To take following items into account before a long idle period..

10

7 Troubleshooting

10

7.1

Symptoms that are NOT system malfunctions ..........................

11

7.1.1

Symptom: A sound like water flowing is heard ........... 11

7.1.2

Symptom: A blowing sound is heard........................... 11

7.1.3

Symptom: A ticking sound is heard............................. 11

7.1.4

Symptom: A whistling sound is heard ......................... 11

7.1.5

Symptom: A clicking sound during operation or idle
time is heard ............................................................... 11

7.1.6

Symptom: A clapping sound is heard ......................... 11

7.1.7

Symptom: The units can give off odours..................... 11

7.1.8

Symptom: The outdoor fan rotates while the air
conditioner is not in operation ..................................... 12

7.2

Solving problems based on error codes....................................

12

8 Disposal

12

1

About the documentation

1.1

About this document

Thank you for purchasing this product. Please:

▪ Keep the documentation for future reference.

Target audience

End users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety  instructions  that  you  must  read  before  operating  your

system

▪ Format: Paper (in the box of the indoor unit)

Operation manual:

▪ Quick guide for basic usage

▪ Format: Paper (in the box of the indoor unit)

User reference guide:

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your installer.

The original documentation is written in English. All other languages
are translations.

2

About the system

WARNING: FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

2.1

Indoor unit

INFORMATION

The  following  figures  are  just  examples  and  may  NOT
completely match your system layout.

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

Summary of Contents for FTXP50L2V1B

Page 1: ...Operation manual R32 split series English Operation manual R32 split series FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B FTXP50L2V1B FTXP60L2V1B FTXP71L2V1B...

Page 2: ...Symptom A clicking sound during operation or idle time is heard 11 7 1 6 Symptom A clapping sound is heard 11 7 1 7 Symptom The units can give off odours 11 7 1 8 Symptom The outdoor fan rotates while...

Page 3: ...g settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 2 2 About the user interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust...

Page 4: ...with screws to the wall or a similar location 3 Hang the user interface on the user interface holder 3 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Inse...

Page 5: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 6: ...used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling...

Page 7: ...in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation Use this feature if the unit is operating and you want t...

Page 8: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 9: ...r air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK...

Page 10: ...35 or frame class 50 71 and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste 6 8 To close the front p...

Page 11: ...oors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation on page 7 Check if there is any furniture directly under or next to the ind...

Page 12: ...e display INFORMATION A short beep and 2 consecutive beeps indicate non corresponding codes To cancel the code display hold the cancel button for 5 seconds The code will also disappear from the displa...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P511999 1C 2018 01 Copyright 2017 Daikin...

Reviews: