background image

6 Maintenance and service

Operation manual

9

FTXP20~71L2V1B
R32 split series
3P511999-1C – 2018.01

DANGER: RISK OF ELECTROCUTION

To  clean  the  air  conditioner  or  air  filter,  be  sure  to  stop
operation  and  turn  all  power  supplies  off.  Otherwise,  an
electric shock and injury may result.

WARNING

To prevent electric shocks or fire:

▪ Do NOT rinse the unit.

▪ Do NOT operate the unit with wet hands.

▪ Do NOT place any objects containing water on the unit.

CAUTION

After  a  long  use,  check  the  unit  stand  and  fitting  for
damage. If damaged, the unit may fall and result in injury.

CAUTION

Do  NOT  touch  the  heat  exchanger  fins.  These  fins  are
sharp and could result in cutting injuries.

WARNING

Be carefull with ladders when working in high places.

6.2

To clean the indoor unit and user
interface

NOTICE

▪ Do  NOT  use  gasoline,  benzene,  thinner  polishing

powder  or  liquid  insecticide. 

Possible  consequence:

Discoloration and deformation.

▪ Do  NOT  use  water  or  air  of  40°C  or  higher. 

Possible

consequence: 

Discoloration and deformation.

▪ Do NOT use polishing compounds.

▪ Do 

NOT 

use 

scrubbing 

brush. 

Possible

consequence: 

The surface finishing peels off.

DANGER: RISK OF ELECTROCUTION

Before  cleaning,  be  sure  to  stop  the  operation,  turn  the
breaker  off  or  pull  out  the  supply  cord.  Otherwise,  an
electric shock and injury may result.

1

Clean  with  a  soft  cloth.  If  it  is  difficult  to  remove  stains,  use
water or a neutral detergent.

6.3

To clean the front panel

1

Clean the front panel with a soft cloth. If it is difficult to remove
stains, use water or a neutral detergent.

6.4

To open the front panel

1

Hold the front panel by the panel tabs on both sides and open
it.

6.5

To clean the air filters

1

Push the tab at the centre of each air filter, then pull it down.

2

Pull out the air filters.

1

2

Note:    (class  50~71) 

The  titanium  apatite  deodorizing  filter  MUST

be removed before cleaning the air filter.

3

Remove the titanium apatite deodorizing filter from all 4 claws.

a

Claw

4

Wash  the  air  filters  with  water  or  clean  them  with  a  vacuum
cleaner.

5

Soak in lukewarm water for about 10 to 15 minutes.

Summary of Contents for FTXP50L2V1B

Page 1: ...Operation manual R32 split series English Operation manual R32 split series FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B FTXP50L2V1B FTXP60L2V1B FTXP71L2V1B...

Page 2: ...Symptom A clicking sound during operation or idle time is heard 11 7 1 6 Symptom A clapping sound is heard 11 7 1 7 Symptom The units can give off odours 11 7 1 8 Symptom The outdoor fan rotates while...

Page 3: ...g settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 2 2 About the user interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust...

Page 4: ...with screws to the wall or a similar location 3 Hang the user interface on the user interface holder 3 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Inse...

Page 5: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 6: ...used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling...

Page 7: ...in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation Use this feature if the unit is operating and you want t...

Page 8: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 9: ...r air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK...

Page 10: ...35 or frame class 50 71 and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste 6 8 To close the front p...

Page 11: ...oors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation on page 7 Check if there is any furniture directly under or next to the ind...

Page 12: ...e display INFORMATION A short beep and 2 consecutive beeps indicate non corresponding codes To cancel the code display hold the cancel button for 5 seconds The code will also disappear from the displa...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P511999 1C 2018 01 Copyright 2017 Daikin...