4 Operation

Operation manual

7

FTXP20~71L2V1B
R32 split series
3P511999-1C – 2018.01

2

Press 

 to stop.

Result: 

 disappears from the LCD.

Note:

  Powerful  operation  can  only  be  set  when  the  unit  is  running.

Press 

 to cancel this mode; 

 disappears from the LCD.

4.3.6

Econo operation

This  is  a  function  which  enables  efficient  operation  by  limiting  the
maximum power consumption value. This function is useful for cases
in which attention should be paid to ensure a circuit breaker will not
trip when the product runs alongside other appliances.

INFORMATION

▪ Powerful and Econo operation CANNOT be used at the

same time. The last selected function takes priority.

▪ Econo  operation  reduces  power  consumption  of  the

outdoor  unit  by  limiting  the  rotation  speed  of  the
compressor.  If  power  consumption  is  already  low,
Econo  operation  will  NOT  further  reduce  power
consumption.

To start/stop Econo operation

1

Press 

 to start.

Result: 

 is displayed on the LCD.

Note:

 Econo operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

 disappears from the LCD.

a

A

B

b

c

d

A

Running current and power consumption

B

Time

a

Maximum during normal operation

b

Maximum during Econo operation

c

Normal operation

d

Econo operation

▪ The diagram can be used for illustrative purposes only.

▪ The  maximum  running  current  and  power  consumption  of  the  air

conditioner in Econo operation varies with the connected outdoor
unit.

4.3.7

OFF/ON timer operation

Timer  functions  are  useful  for  automatically  switching  the  air
conditioner on/off at night or in the morning. You can also use OFF
timer and ON timer in combination.

INFORMATION

Program the timer again in case of:

▪ A breaker has turned the unit off.

▪ A power failure.

▪ After replacing batteries in the user interface.

To start/stop OFF timer operation

Use  this  feature  if  the  unit  is  operating  and  you  want  to  stop
operation after a certain time.

1

Press 

.

Result: 

  is  displayed  on  the  LCD  and  the  timer  lamp

lights up.

2

Press 

 again if you want to change the time setting.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

Example: 

 If 

 is set when the unit is operating, operation

will stop after 5 hours.

3

To cancel the setting, press 

.

Result: 

  and  the  time  setting  disappear  from  the  LCD  and  the

timer lamp goes off.

INFORMATION

Night set mode

When  the  OFF  timer  is  set,  the  air  conditioner
automatically  adjusts  the  temperature  setting  (0.5°C  up  in
cooling,  2.0°C  down  in  heating)  to  prevent  excessive
cooling/heating  and  ensure  a  comfortable  sleeping
temperature.

To start/stop ON timer operation

Use  this  feature  if  the  unit  is  NOT  operating  and  you  want  to  start
operation after a certain time.

1

Press 

.

Result: 

  is  displayed  on  the  LCD  and  the  timer  lamp

lights up.

2

Press 

 again if you want to change the time setting.

INFORMATION

Each time 

 is pressed, the time setting advances by

1 hour. The timer can be set between 1 to 12 hours.

Example: 

  If 

  is  set  when  the  unit  is  NOT  operating,

operation will start after 2 hours.

3

To cancel the setting, press 

.

Result: 

  and  the  time  setting  disappear  from  the  LCD  and  the

timer lamp goes off.

To combine OFF timer and ON timer

1

To set the timers, refer to 

"To start/stop OFF timer operation" on

page 7

 and 

"To start/stop ON timer operation" on page 7

.

Result: 

 and 

 are displayed on the LCD.

Example:

2

If 

 is set when the unit is operating.

Result: 

Operation 

stops

  in  1  hour  and  then 

starts

  7  hours

later.

3

If 

  is  set  when  the  unit  is  NOT

operating.

Summary of Contents for FTXP50L2V1B

Page 1: ...Operation manual R32 split series English Operation manual R32 split series FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B FTXP50L2V1B FTXP60L2V1B FTXP71L2V1B...

Page 2: ...Symptom A clicking sound during operation or idle time is heard 11 7 1 6 Symptom A clapping sound is heard 11 7 1 7 Symptom The units can give off odours 11 7 1 8 Symptom The outdoor fan rotates while...

Page 3: ...g settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 2 2 About the user interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust...

Page 4: ...with screws to the wall or a similar location 3 Hang the user interface on the user interface holder 3 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Inse...

Page 5: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 6: ...used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling...

Page 7: ...in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation Use this feature if the unit is operating and you want t...

Page 8: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 9: ...r air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK...

Page 10: ...35 or frame class 50 71 and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste 6 8 To close the front p...

Page 11: ...oors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation on page 7 Check if there is any furniture directly under or next to the ind...

Page 12: ...e display INFORMATION A short beep and 2 consecutive beeps indicate non corresponding codes To cancel the code display hold the cancel button for 5 seconds The code will also disappear from the displa...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P511999 1C 2018 01 Copyright 2017 Daikin...

Reviews: