To adjust the airflow rate

1

Press 

 to change the airflow setting as follows:

4.3.3

Airflow direction

When.

 Adjust the airflow direction as desired.

What.

  The  system  directs  the  airflow  differently,  depending  on  the

user selection (swinging or fixed position). It does so by moving the
vertical blades.

Setting

Airflow direction

 Vertical auto swing

Moves up and down.

[—]

Stays in a fixed position.

CAUTION

▪ ALWAYS use a user interface to adjust the angle of the

flap. When the flap is swinging and you move it forcibly
by hand, the mechanism will break.

▪ Be  careful  when  adjusting  the  louvers.  Inside  the  air

outlet, a fan is rotating at high speed.

Note:

  The  movable  range  of  the  flap  varies  according  to  the

operation  mode.  The  flap  will  stop  at  the  upper  position  when  the
airflow rate is changed to low during the up and down swing setting.

a

b

c

a

Flap range in cooling or drying operation

b

Flap range in heating operation

c

Flap range in fan only operation

To adjust the airflow direction

1

To use auto swing, press 

.

Result: 

 will appear on the LCD.

Result: 

The flap (horizontal blade) will begin to swing.

2

To  use  fixed  position,  press 

  when  the  flap  reaches  the

desired position.

Result: 

 disappears from the LCD.

To adjust the louvers (vertical blades)

1

Hold 1 or both knobs and move the louvers.

a

a

a

Knobs

INFORMATION

When  the  unit  is  installed  in  a  corner  of  a  room,  the
direction  of  the  louvers  should  be  facing  away  from  the
wall. Efficiency will drop if a wall blocks the air.

4.3.4

Comfort airflow operation

This operation can be used in 

Heating

 or 

Cooling

 operation mode.

It will provide a comfortable wind that will NOT come in direct contact
with people. The system automatically sets the fixed airflow position
upward in Cooling and downward in Heating operation mode.

INFORMATION

Powerful and Comfort airflow operation CANNOT be used
at the same time. The last selected function takes priority.
If the Vertical automatic swing is selected, Comfort airflow
operation will be cancelled.

To start/stop Comfort airflow operation

1

Press 

 to start.

Result: 

The  flap  position  will  change, 

  is  displayed  on  the

LCD, and the airflow rate is set to automatic.

Mode

Position of flap…

Cooling/Drying

Up

Heating

Down

Note: 

Comfort airflow operation is NOT available in Fan only mode.

2

Press 

 to stop.

Result: 

The  flap  will  return  to  the  position  from  before  the  Comfort

airflow mode; 

 disappears from the LCD.

4.3.5

Powerful operation

This  operation  quickly  maximizes  the  cooling/heating  effect  in  any
operation mode. You can get the maximum capacity.

INFORMATION

Powerful operation CANNOT be used together with Econo
and  Comfort  airflow  operation.  The  last  selected  function
takes priority.

Powerful  operation  will  NOT  increase  the  capacity  of  the
unit if it already operates at maximum capacity.

To start/stop Powerful operation

1

Press 

 to start.

Result: 

  is  displayed  on  the  LCD.  Powerful  operation  runs

for 20 minutes; after that, operation returns to the previously set
mode.

Mode

Airflow rate

Cooling/Heating/Automatic

▪ To  maximize  the  cooling/

heating  effect,  the  capacity  of
outdoor unit is increased.

▪ The  airflow  rate  is  fixed  to  the

maximum setting.

The temperature and airflow
settings CANNOT be changed.

Drying

▪ The  temperature  setting  is

lowered by 2.5°C.

▪ The  airflow  rate  is  slightly

increased.

Fan only

The airflow rate is fixed to the
maximum setting.

Summary of Contents for FTXP50L2V1B

Page 1: ...Operation manual R32 split series English Operation manual R32 split series FTXP20L2V1B FTXP25L2V1B FTXP35L2V1B FTXP50L2V1B FTXP60L2V1B FTXP71L2V1B...

Page 2: ...Symptom A clicking sound during operation or idle time is heard 11 7 1 6 Symptom A clapping sound is heard 11 7 1 7 Symptom The units can give off odours 11 7 1 8 Symptom The outdoor fan rotates while...

Page 3: ...g settings are used Operation mode Automatic Temperature setting 25 C Airflow rate Automatic 2 2 About the user interface Direct sunlight Do NOT expose the user interface to direct sunlight Dust Dust...

Page 4: ...with screws to the wall or a similar location 3 Hang the user interface on the user interface holder 3 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Inse...

Page 5: ...a room to the temperature setpoint Cooling The system cools down a room to the temperature setpoint Fan The system only controls the airflow airflow rate and airflow direction The system does NOT cont...

Page 6: ...used in Heating or Cooling operation mode It will provide a comfortable wind that will NOT come in direct contact with people The system automatically sets the fixed airflow position upward in Cooling...

Page 7: ...in case of A breaker has turned the unit off A power failure After replacing batteries in the user interface To start stop OFF timer operation Use this feature if the unit is operating and you want t...

Page 8: ...the room temperature properly for a comfortable environment Avoid excessive heating or cooling Notice that it may take some time for the room temperature to reach the set temperature Consider using th...

Page 9: ...r air of 40 C or higher Possible consequence Discoloration and deformation Do NOT use polishing compounds Do NOT use a scrubbing brush Possible consequence The surface finishing peels off DANGER RISK...

Page 10: ...35 or frame class 50 71 and replace the filter with a new one INFORMATION Do NOT throw away the filter frame but use it again Dispose of the old filter as non flammable waste 6 8 To close the front p...

Page 11: ...oors and windows to prevent wind from coming in Check if the unit operates in Econo operation Refer to 4 3 6 Econo operation on page 7 Check if there is any furniture directly under or next to the ind...

Page 12: ...e display INFORMATION A short beep and 2 consecutive beeps indicate non corresponding codes To cancel the code display hold the cancel button for 5 seconds The code will also disappear from the displa...

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...3P511999 1C 2018 01 Copyright 2017 Daikin...

Reviews: