background image

6-9  To remove the front panel

 INFORMATION

Remove the front panel only in case it MUST be replaced.

1. 

Open the front panel. See “6-4 To open the front panel” on 

page 17.

2. 

Open the panel locks located on the back side of the panel 
(1 on each side).

a

a

Panel lock

3. 

Push the right arm lightly to the right to disconnect the 
shaft from the shaft slot on the right side.

a

c

b

Arm

Shaft

Shaft slot

4. 

Disconnect the front panel shaft from the shaft slot on the 
left side.

a

c

b

Arm

Shaft slot

Shaft

5. 

Remove the front panel.

6. 

To re-install the front panel perform the steps in the opposite 
order.

6-10 

Take following items into account before a long 

idle period

Operate the unit several hours in 

fan only

 mode to dry the inside 

of the unit.

1. 

Press 

 and select 

 operation.

2. 

Press 

 and start operation.

3. 

After operation stops, turn the circuit breaker off.

4. 

Clean the air filters and replace them in their original position.

5. 

Remove the batteries from the remote controller.

• 

When starting to use the air conditioner again, make sure that the 
drain hose outlet is not blocked, then turn on the circuit breaker. 
An operational check of each component will be carried out 
automatically. (Also, put the batteries into the remote controller.)

 INFORMATION

It is recommended to have periodical maintenance performed 
by a specialist. For specialist maintenance, contact your dealer. 
Maintenance costs shall be borne by the user.

In certain operating conditions the inside of the unit may get dirty 
after several seasons of use. This results in poor performance.

7.  Troubleshooting

If one of the following malfunctions occur, take the measures 
shown below and contact your dealer.

 WARNING

Stop operation and shut off the power if anything 

unusual occurs (burning smells etc.).

Leaving the unit running under such circumstances may cause 

breakage, electric shock or fire. Contact your dealer.

The system MUST be repaired by a qualified service person:

Malfunction

Measure

If a safety device such as a fuse, a 
circuit breaker or an earth leakage 
circuit breaker frequently actuates 
or the ON/OFF switch does NOT 
properly work.

Turn OFF the main power 
switch.

Water is leaking from the indoor unit If the drain hose is crushed 

or clogged, water from the 
indoor unit may be unable 
to drain and start leaking. 
Stop operation of the unit 
immediately and contact 
your dealer.

The operation switch does NOT 
work well.

Turn OFF the power 
supply.

If the remote controller display 
indicates the unit number, the 

operation lamp flashes and the 

malfunction code appears.

Notify your installer and 
report the malfunction 
code.

If the system does NOT properly operate except for the above 
mentioned cases and none of the above mentioned malfunctions 
is evident, investigate the system according to the following 
procedures.

19 

01_EN_3P524249-1.indd   19

6/12/2018   1:47:46 PM

Summary of Contents for FTXJ25TVMAK

Page 1: ...round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25TVMAW FTXJ35TVMAW FTXJ50TVMAW FTXJ60TVMAW FTXJ25TVMAK...

Page 2: ...t panel 17 6 4 To open the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To re...

Page 3: ...ty pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shock CAUTION Do not use the air conditioner for purposes other than those for which it is intended Do not...

Page 4: ...e Front panel f Service lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye l...

Page 5: ...n is active Operation mode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit qui...

Page 6: ...esulting in battery leakage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front...

Page 7: ...indoor unit position to avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blin...

Page 8: ...a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a...

Page 9: ...up and down swing setting a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps...

Page 10: ...tically returns to the default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts th...

Page 11: ...he outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor...

Page 12: ...o stop operation press Result and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stor...

Page 13: ...ock on page 5 INFORMATION Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When...

Page 14: ...ons You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week an...

Page 15: ...To install the Daikin Mobile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on...

Page 16: ...he screen 7 Connect your smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between th...

Page 17: ...the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if...

Page 18: ...els off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean wi...

Page 19: ...te deodorising filter INFORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old fil...

Page 20: ...ance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after se...

Page 21: ...lfunction Measure The system operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wai...

Page 22: ...flaps louvres or front panel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White m...

Page 23: ...http www daikinthai com dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the re...

Page 24: ...3P524249 1 M17B306 1806 HT The two dimensional bar code is a manufacturing code...