3. 

Press 

 to confirm the selection.

 

Result:

   is blinking.

4. 

Press the WPS button on your communication device 
(e.g.router) within approximately 1 minute. Refer to the 
manual of your communication device. 

Result:

 The timer LED is blinking.

5. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

Note:

 If the blinking of the timer lamp does not slow down and 

the timer lamp goes out, repeat steps 1 through 5.

If connection is still impossible, use the procedures in “To 
connect the wireless adapter to your device directly” to perform 

setting.

To connect the wireless adapter to your device 

directly

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the AP setting display 

(menu   ) appears.

3. 

Press 

 to confirm the selection.

 

Result:

   is blinking.

4. 

Connect with your smart device to the access point in the 
same way as to a standard wireless network.

• 

Select the SSID (DaikinAP*****) printed on the unit or 
in the accessory set, and enter the password.

Result:

 The operation and timer LEDs are blinking.

5. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

6. 

Open the application and tap “Configure the wireless 
connection”, then connect to the home network following 

the instructions on the screen.

7. 

Connect your smartphone to the home network.

To reset the connection setting to the factory default

Reset the connection setting to the factory default in case you 
want to:

• 

switch between the WPS and the AP connection option,

• 

disconnect the Wi-Fi adapter and the communication device 
(e.g.router) or smart device,

• 

repeat the setting if the connection was unsuccessful.

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the A display (menu  ) 

appears.

3. 

Hold 

 for at least 2 seconds to confirm the selection.

 

Result:

   is blinking. The setting is reset to the factory default.

4. 

Press 

 to exit the menu. 

Result:

 The display will return to the default screen.

To turn off the wireless connection

You can turn off the wireless connection using:

• 

the remote controller,

• 

the wireless adapter ON/OFF button on the unit.

To use the wireless adapter ON/OFF switch

1. 

Press the wireless adapter ON/OFF switch. 

Result:

 The wireless adapter communication is OFF.

Note:

 Press the ON/OFF switch again to turn on the wireless 

adapter.

To use the remote controller

1. 

Hold 

 for at least 5 seconds in the default screen. 

Result:

 The confirmation display (menu 

 ) appears.

2. 

Press repeatedly 

 or 

 until the OFF menu appears.

3. 

Hold 

 for at least 2 seconds to confirm the selection.

 

Result:

 

 is blinking. Communication is OFF. The 

operation and timer LEDs are blinking.

4. 

Press 

 to exit the menu.

Result:

 The display will return to the default screen.

15 

01_EN_3P524249-1.indd   15

6/12/2018   1:47:41 PM

Summary of Contents for FTXJ25TVMAK

Page 1: ...round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25TVMAW FTXJ35TVMAW FTXJ50TVMAW FTXJ60TVMAW FTXJ25TVMAK...

Page 2: ...t panel 17 6 4 To open the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To re...

Page 3: ...ty pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shock CAUTION Do not use the air conditioner for purposes other than those for which it is intended Do not...

Page 4: ...e Front panel f Service lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye l...

Page 5: ...n is active Operation mode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit qui...

Page 6: ...esulting in battery leakage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front...

Page 7: ...indoor unit position to avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blin...

Page 8: ...a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a...

Page 9: ...up and down swing setting a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps...

Page 10: ...tically returns to the default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts th...

Page 11: ...he outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor...

Page 12: ...o stop operation press Result and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stor...

Page 13: ...ock on page 5 INFORMATION Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When...

Page 14: ...ons You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week an...

Page 15: ...To install the Daikin Mobile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on...

Page 16: ...he screen 7 Connect your smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between th...

Page 17: ...the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if...

Page 18: ...els off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean wi...

Page 19: ...te deodorising filter INFORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old fil...

Page 20: ...ance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after se...

Page 21: ...lfunction Measure The system operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wai...

Page 22: ...flaps louvres or front panel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White m...

Page 23: ...http www daikinthai com dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the re...

Page 24: ...3P524249 1 M17B306 1806 HT The two dimensional bar code is a manufacturing code...