background image

5.  Energy saving and optimum operation

 INFORMATION

• 

Even if the unit is turned OFF, it consumes electricity.

• 

When the power turns back on after a power break, the 
previously selected mode will be resumed.

 CAUTION

NEVER expose little children, plants or animals directly to the 

airflow.

 WARNING

Do NOT place objects below the indoor and/or outdoor unit that 
may get wet. Otherwise condensation on the unit or refrigerant 

pipes, air filter dirt or drain blockage may cause dripping, and 

objects under the unit may get dirty or damaged.

 NOTICE

Do NOT use the system for other purposes. In order to avoid 
any quality deterioration, do NOT use the unit for cooling 
precision instruments, food, plants, animals, or works of art.

 WARNING

Do NOT place a flammable spray bottle near the air conditioner 
and do NOT use sprays. Doing so may result in a fire.

Observe the following precautions to ensure the system 
operates properly.

• 

Prevent direct sunlight from entering a room during cooling 
operation by using curtains or blinds.

• 

Ventilate often. Extended use requires special attention to 
ventilation.

• 

Keep doors and windows closed. If the doors and windows 

remain open, air will flow out of your room causing a decrease 

in the cooling or heating effect.

• 

Be careful NOT to cool or heat too much. To save energy, keep 
the temperature setting at a moderate level.

• 

NEVER place objects near the air inlet or the air outlet of the unit. 
Doing so may cause a reduced heating/cooling effect or stop 
operation.

• 

Turn off the main power supply switch to the unit when the 
unit is NOT used for longer periods of time. If the main power 
supply switch is on, the unit consumes electricity. Before 
restarting the unit, turn on the main power supply switch 6 
hours before operation to ensure smooth running.

• 

Condensation may form if the humidity is above 80% or if the 

drain outlet gets blocked.

• 

Adjust the room temperature properly for a comfortable 
environment. Avoid excessive heating or cooling. Notice that 
it may take some time for the room temperature to reach the 
set temperature. Consider using the timer setting options.

• 

Adjust the airflow direction to avoid cool air from gathering on 
the floor or warm air against the ceiling. (Up during cooling or 

dry operation to the ceiling and down during heating operation.)

• 

Avoid direct airflow to room inhabitants.

• 

Operate the system within the recommended temperature range 
(26~28°C for cooling and 20~24°C for heating) to save energy.

6.  Maintenance and service

6-1 

Overview: Maintenance and service

The installer has to perform yearly maintenance.

 WARNING

• 

The refrigerant inside the unit is mildly flammable, but normally 

does NOT leak. If the refrigerant leaks in the room and comes 

in contact with fire from a burner, a heater, or a cooker, this 
may result in fire, or the formation of a harmful gas.

• 

Turn off any combustible heating devices, ventilate the room, 
and contact the dealer where you purchased the unit.

• 

Do NOT use the unit until a service person confirms that the 

part from which the refrigerant leaked has been repaired.

• 

Do NOT pierce or burn refrigerant cycle parts.

• 

Do NOT use cleaning materials or means to accelerate the 
defrosting process other than those recommended by the 
manufacturer.

• 

Be aware that the refrigerant inside the system is odourless.

• 

The appliance shall be stored in a room without continuously 

operating ignition sources (example: open flames, an 

operating gas appliance or an operating electric heater).

 16

01_EN_3P524249-1.indd   16

6/12/2018   1:47:42 PM

Summary of Contents for FTXJ25TVMAK

Page 1: ...round comfort Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FTXJ25TVMAW FTXJ35TVMAW FTXJ50TVMAW FTXJ60TVMAW FTXJ25TVMAK...

Page 2: ...t panel 17 6 4 To open the front panel 17 6 5 About the air filters 17 6 6 To clean the air filters 18 6 7 To clean the titanium apatite deodorising filter 18 6 8 To close the front panel 18 6 9 To re...

Page 3: ...ty pipe lightning conductor or telephone earth lead Imperfect earthing may result in electric shock CAUTION Do not use the air conditioner for purposes other than those for which it is intended Do not...

Page 4: ...e Front panel f Service lid g Intelligent eye sensor h Display i Room temperature and humidity sensor j ON OFF button and operation lamp green k Signal receiver l Timer lamp orange m Intelligent eye l...

Page 5: ...n is active Operation mode Automatic Operation mode Drying Operation mode Heating Operation mode Cooling Operation mode Fan only Powerful operation is active Econo operation is active Outdoor unit qui...

Page 6: ...esulting in battery leakage rupturing or heating Do not damage or peel off labels on the batteries 1 Slide the front cover to take it off 2 Insert 2 dry batteries AAA LR03 alkaline 3 Replace the front...

Page 7: ...indoor unit position to avoid direct airflow to walls 1 Press for at least 2 seconds Result The menu appears on the display 2 Press or to change the menu to Result The menu appears on the display blin...

Page 8: ...a room without heating or cooling Decrease the humidity in a room What The system operates differently depending on the user selection Setting Description Automatic The system cools down or heats up a...

Page 9: ...up and down swing setting a b a Flap range in cooling or drying operation b Flap range in heating or fan only operation To adjust vertical airflow direction 1 Press Result appears on the LCD The flaps...

Page 10: ...tically returns to the default screen after 60 seconds To return to the default screen sooner press twice Intelligent eye operation The system detects movement in the room and automatically adjusts th...

Page 11: ...he outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumption Outdoor unit quiet operation Use Outdoor...

Page 12: ...o stop operation press Result and disappear from the LCD and the timer lamp goes off and the day of the week are displayed on the LCD INFORMATION When you set the ON OFF timer the time setting is stor...

Page 13: ...ock on page 5 INFORMATION Weekly timer and ON OFF timer operation CANNOT be used at the same time The ON OFF timer operation takes priority Weekly timer will be in standby disappears from the LCD When...

Page 14: ...ons You can confirm if all reservations are set to your needs 1 Press Result The day of the week and the reservation number of the current day are displayed 2 Press or to select the day of the week an...

Page 15: ...To install the Daikin Mobile Controller application 1 Open Google Play for appliances using Android App Store for appliances using iOS 2 Search for Daikin Mobile Controller 3 Follow the directions on...

Page 16: ...he screen 7 Connect your smartphone to the home network To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to switch between th...

Page 17: ...the unit consumes electricity Before restarting the unit turn on the main power supply switch 6 hours before operation to ensure smooth running Condensation may form if the humidity is above 80 or if...

Page 18: ...els off DANGER RISK OF ELECTROCUTION Before cleaning be sure to stop the operation turn the circuit breaker off or pull out the supply cord Otherwise an electric shock and injury may result 1 Clean wi...

Page 19: ...te deodorising filter INFORMATION Clean the filter with water every 6 months 1 Remove the dust from the filter with a vacuum cleaner INFORMATION Replace the filter every 3 years Dispose of the old fil...

Page 20: ...ance performed by a specialist For specialist maintenance contact your dealer Maintenance costs shall be borne by the user In certain operating conditions the inside of the unit may get dirty after se...

Page 21: ...lfunction Measure The system operates but heating is insufficient air is NOT blown from the unit To prevent the release of cold air air does not come out directly after operation is started Please wai...

Page 22: ...flaps louvres or front panel correct their positions at the beginning or end of operation or while operation is stopped It is the sound of the flaps louvres or front panel moving 7 1 9 Symptom White m...

Page 23: ...http www daikinthai com dmobile index html for more information and FAQ Problem Measure Connection to the WLAN adapter is not possible none of the LEDs are blinking Try operating the unit with the re...

Page 24: ...3P524249 1 M17B306 1806 HT The two dimensional bar code is a manufacturing code...