background image

5 Operation

Operation manual

8

FTXJ-A(W)(S)(B)

Daikin room air conditioner

3P485919-15W – 2021.12

3

Press 

  to  exit  to  the  home  screen  or  use  EXIT  screen  to

return to “indoor unit setting menu”.

To connect using SSID and KEY number

1

Open  the  ONECTA  app  on  your  smart  device  and  follow  the
steps on the screen.

2

Connect  your  smart  device  to  the  same  home  network  as  the
unit.

3

Check if the connection was successful (refer to 

"To confirm the

wireless LAN connection status"

 [

4

 8]).

4

Press 

  to  exit  to  the  home  screen  or  use  EXIT  screen  to

return to “indoor unit setting menu”.

To confirm the wireless LAN connection status

1

Navigate  to  the  status  screen  using 

  and 

.  Press 

  to

confirm.

Status screen

STATUS

2

Check the Daikin eye.

b

c

a

a

Daikin eye

b

Partly green

c

Red, orange or blue

Daikin eye colour alternates
between partly green and…

…then wireless adapter is…

Red

not connected

orange

running and ready to connect to
the home network via WPS
button; see 

"To connect using

the WPS button"

 [

4

 7].

blue

connected to the home network:

▪ via SSID + KEY.

or

▪ via  the  WPS  button  on  the

router.

3

Press 

  to  exit  to  the  home  screen  or  use  EXIT  screen  to

return to the indoor unit setting menu.

To reset the connection setting to the factory default

Reset the connection setting to the factory default in case you want
to:

▪ disconnect  the  wireless  LAN  and  the  communication  device  (e.g.

router) or smart device.

▪ repeat the setting if the connection was unsuccessful.

1

Navigate to the RESET screen using 

 and 

. Press 

 to

confirm your selection.

Result: 

The setting is reset to the factory default.

Reset screen

RESET

2

Press 

  to  exit  to  the  home  screen  or  use  EXIT  screen  to

return to the indoor unit setting menu.

To turn off the wireless LAN connection

1

Enter  the  wireless  LAN  connection  setting  menu  and  change

the setting to OFF using 

 and 

. Press 

 to confirm your

selection.

Result: 

The  Daikin  eye  alternates  between  green  and  white.

Communication is OFF.

4.4.3

Vertical airflow function

This function helps with optimal airflow and temperature distribution
in  heating  operation  mode.  You  can  turn  this  function  OFF  in  case
there is furniture or another object under the unit.

Vertical airflow OFF

Vertical airflow ON

To turn ON/OFF vertical airflow function

1

In  the  indoor  unit  setting  menu,  navigate  to  the  vertical  airflow

setting using 

 and 

.

Vertical airflow function ON

Vertical airflow function OFF

2

Change the setting using 

 and 

.

3

Press 

 to confirm your selection.

4

Press 

  again  to  return  to  the  main  menu  or  press 

  to

return to the home screen.

5

Operation

INFORMATION

The  indoor  unit  is  delivered  with  the  wireless  remote
control  as  the  user  interface.  This  manual  describes  only
operation with this user interface. If another user interface
is  connected,  refer  to  the  operation  manual  of  the
connected user interface.

5.1

Operation range

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Cooling and

drying

(a)(b)

Heating

(a)

Outdoor temperature for
RXJ models

–10~50°C DB

–20~24°C DB

–21~18°C WB

Summary of Contents for FTXJ20A2V1BW

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: