CAUTION

Do NOT touch the heat exchanger fins.
These fins are sharp and could result
in cutting injuries.

WARNING

Be careful with ladders when working
in high places.

WARNING

Improper detergents or cleaning
procedure may cause damage on
plastic components or water leakage.
Splashed detergent on electric
components, such as motors, may
cause failure, smoke or ignition.

DANGER: RISK OF
ELECTROCUTION

Before cleaning, be sure to stop the
operation, turn the breaker OFF or pull
out the supply cord. Otherwise, an
electrical shock and injury may result.

WARNING

Stop operation and shut OFF the
power if anything unusual occurs
(burning smells etc.).

Leaving the unit running under such
circumstances may cause breakage,
electrical shock or fire. Contact your
dealer.

3

About the system

WARNING: MILDLY FLAMMABLE MATERIAL

The refrigerant inside this unit is mildly flammable.

CAUTION

The  indoor  unit  contains  radio  equipment,  minimum
separation  distance  between  the  radiating  part  of  the
equipment and the user is 10 cm.

NOTICE

Do  NOT  use  the  system  for  other  purposes.  In  order  to
avoid  any  quality  deterioration,  do  NOT  use  the  unit  for
cooling  precision  instruments,  food,  plants,  animals,  or
works of art.

3.1

Indoor unit

CAUTION

Do  NOT  insert  fingers,  rods  or  other  objects  into  the  air
inlet or outlet. When the fan is rotating at high speed, it will
cause injury.

INFORMATION

The sound pressure level is less than 70 dBA.

WARNING

▪ Do  NOT  modify,  disassemble,  remove,  reinstall  or

repair  the  unit  yourself  as  incorrect  dismantling  or
installation  may  cause  an  electrical  shock  or  fire.
Contact your dealer.

▪ In case of accidental refrigerant leaks, make sure there

are  no  naked  flames.  The  refrigerant  itself  is  entirely
safe,  non-toxic  and  mildly  flammable,  but  it  will
generate  toxic  gas  when  it  accidentally  leaks  into  a
room  where  combustible  air  from  fan  heaters,  gas
cookers,  etc.  is  present.  Always  have  qualified  service
personnel  confirm  that  the  point  of  leakage  has  been
repaired or corrected before resuming operation.

ON/OFF button

If the user interface (e.g. wireless remote control) is missing, you can
use  the  ON/OFF  button  on  the  indoor  unit  to  start/stop  operation.
When  operation  is  started  using  this  button,  the  following  settings
are used:

▪ Operation mode = Automatic

▪ Temperature setting = 25°C

▪ Airflow rate = Automatic

3.1.1

Daikin eye indication lamp

The Daikin eye colour will change according to operation.

a

b

a

ON/OFF button

b

Daikin eye (with infrared signal receiver)

Operation

Daikin eye colour

Automatic

Red/blue

Cooling

Blue

Heating

Red

Fan only

White

Drying

Green

Timer operation

Orange

(a)

(a)

When the OFF/ON timer or Weekly timer operation is set, the
Daikin eye periodically changes to orange. After lighting orange
for about 10 seconds, it returns to the colour of the operation
mode for 3 minutes. 

Example: 

 When the timer is set during

cooling operation, the Daikin eye will periodically light orange for
10 seconds, and then switch to blue for 3 minutes.

Summary of Contents for FTXJ20A2V1BW

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: