background image

4 Before operation

Operation manual

6

FTXJ-A(W)(S)(B)

Daikin room air conditioner

3P485919-15W – 2021.12

4.2

To mount the wireless remote
control magnetic holder

c

b

a

a

Wireless remote controller

b

Screws (field supply)

c

Wireless remote controller magnetic holder

1

Choose a place where the signals reach the unit.

2

Attach the holder with screws to the wall or a similar location.

3

Hang the wireless remote control on the holder.

INFORMATION

The wireless remote control holder is magnetic. Make sure
to install the holder with the right side up.

4.3

To turn on the power supply

1

Turn the circuit breaker on.

Result: 

The  flap  of  the  indoor  unit  will  open  and  close  to  set  the

reference position.

4.4

Indoor unit setting

1

Enter the main menu by pressing 

 and navigate to the indoor

unit  setting  menu  using 

  and 

.  Press 

  to  enter  the

menu.

Indoor unit setting menu

2

Perform the settings listed below.

3

Press 

 to return to the main menu or press 

 to exit to the

home screen.

4.4.1

Open the front panel

The  front  panel  opens  automatically  when  the  operation  starts.
When you want to open the front panel when the operation is OFF,
use this feature. 

Example: 

 during maintenance.

To open the front panel using the wireless remote
control

1

Make sure the operation is OFF. If not, turn it OFF using 

.

2

In  the  indoor  unit  setting  menu,  navigate  to  the  open  the  front

panel screen using 

 and 

.

Open the front panel screen

SEND

3

Press 

 to confirm.

Result: 

The front panel opens.

4

Press 

 again to close the front panel or press 

 to return to

the home screen.

4.4.2

Wireless LAN connection

Simply  connect  your  unit  to  your  home  network  and  download  the
app  to  change  the  thermostat,  set  temperature  schedules,  review
your energy consumption and more.

For details on specifications, setting methods, FAQ, troubleshooting
tips, visit 

app.daikineurope.com

.

The customer is responsible for providing:

▪ Smartphone or tablet with minimum supported version of Android

or iOS, specified on 

app.daikineurope.com

.

▪ Internet line and communication device, such as a modem, router,

etc.

▪ Wireless LAN access point

▪ Installed free ONECTA app

Note: 

If  needed,  the  SSID  (Service  Set  Identifier)  and  the  KEY

(password) are located on the unit.

a

a

Label with the SSID and the KEY

Precautions when using the wireless LAN

Do NOT use near:

Medical  equipment.

  E.g.  persons  using  cardiac  pacemakers  or

defibrillators. 

This 

product 

may 

cause 

electromagnetic

interference.

Auto-control  equipment.

  E.g.  automatic  doors  or  fire  alarm

equipment.  This  product  may  cause  faulty  behaviour  of  the
equipment.

Microwave oven.

 It may affect wireless LAN communications.

To install the ONECTA app

1

Open:

▪ Google Play for appliances using Android.
▪ App Store for appliances using iOS.

2

Search for “ONECTA”.

3

Follow the directions on the screen to install.

Summary of Contents for FTXJ20A2V1BW

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: