background image

5 Operation

Operation manual

9

FTXJ-A(W)(S)(B)
Daikin room air conditioner
3P485919-15W – 2021.12

Cooling and

drying

(a)(b)

Heating

(a)

Outdoor temperature for
2MXM, 3MXM, 4MXM,
5MXM models

–10~46°C DB

–15~24°C DB

–15~18°C WB

Indoor temperature

18~37°C DB

14~28°C WB

10~30°C DB

Indoor humidity

≤80%

(a)

(a)

A safety device might stop the operation of the system if the unit
runs outside its operation range.

(b)

Condensation and water dripping might occur if the unit runs
outside its operation range.

5.2

Operation mode and temperature
setpoint

When.

  Adjust  the  system  operation  mode  and  set  the  temperature

when you want to:

▪ Heat up or cool down a room

▪ Blow air in a room without heating or cooling

▪ Decrease the humidity in a room

What.

  The  system  operates  differently,  depending  on  the  user

selection.

Setting

Description

Automatic

The system cools down or heats up a room to
the temperature setpoint. It automatically
switches between cooling and heating if
necessary.

Cooling

The system cools down a room to the
temperature setpoint.

Heating

The system heats up a room to the
temperature setpoint.

Heat boost

This feature is automatic; it quickly heats up
your home when starting up the unit in heating
mode.

Fan only

The system only controls the airflow (airflow
rate and airflow direction).

During this operation you CANNOT set the
temperature.

Drying

The system decreases the humidity in the
room.

During this operation you CANNOT set the
temperature.

Additional info:

Outside  temperature.

  The  system's  cooling  or  heating  effect

decreases when the outside temperature is too high or too low.

Defrost operation.

 During heating operation, frost might occur on

the  outdoor  unit  and  decrease  the  heating  capacity.  In  that  case,
the  system  automatically  switches  to  defrosting  operation  to
remove  the  frost.  During  defrosting  operation,  hot  air  is  NOT
blown from the indoor unit.

Humidity  sensor.

  Control  the  humidity  by  decreasing  the

humidity during cooling process.

5.2.1

To start/stop operation mode and to set
the temperature

Operation mode

1

Press 

  to  enter  the  operation  mode  carousel  menu.  When

 is pressed repeatedly, the mode will change as follows:

INFORMATION

▪ In  the  carousel  menu,  you  can  also  navigate  in  both

directions using 

 and 

 or 

 and 

.

▪ The  carousel  menu  will  always  start  with  the  currently

active setting.

2

Press 

 to 

start

 operation.

3

The  home  screen  changes  as  follows  and  the  Daikin  eye
indication lamp goes ON.

Home screen when unit is ON during…

heating, cooling,

automatic operation

drying operation

fan only operation

Temperature setpoint

4

Press 

  or 

  one  or  more  times  to  lower  or  raise  the

temperature setpoint

.

Cooling
operation

Heating
operation

Automatic
operation

Drying or fan
only operation

18~32°C

10~30°C

18~30°C

No setpoint

(a)

(a)

When using 

drying

 or 

fan only

 operation mode, you CANNOT

adjust the temperature.

5

Press 

 to 

stop

 operation.

Result: 

The  home  screen  changes  as  follows  and  the  Daikin  eye

indication lamp goes OFF.

Home screen when the unit is OFF

5.3

Airflow rate

INFORMATION

▪ When  using  drying  operation  mode,  you  CANNOT

adjust the airflow rate setting.

▪ The  airflow  rate  in  heating  mode  will  lower  to  avoid

generating  cold  airflow.  When  temperature  of  the
airflow  rise,  operation  will  continue  at  the  set  airflow
rate.

You  can  adjust  the  strength  of  the  airflow  coming  out  of  the  indoor
unit.

Setting

Description

Fan speed 1~5

 ~ 

5 airflow rate levels from low to high.

Summary of Contents for FTXJ20A2V1BW

Page 1: ...nglish Operation manual Daikin room air conditioner FTXJ20A2V1BW FTXJ25A2V1BW FTXJ35A2V1BW FTXJ42A2V1BW FTXJ50A2V1BW FTXJ20A2V1BS FTXJ25A2V1BS FTXJ35A2V1BS FTXJ42A2V1BS FTXJ50A2V1BS FTXJ20A2V1BB FTXJ2...

Page 2: ...5 To clean the air filters 17 7 6 To clean the titanium apatite deodorising filter and the silver particle filter Ag ion filter 17 7 7 To replace the titanium apatite deodorising filter and the silver...

Page 3: ...ON Do NOT operate the system when using a room fumigation type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrige...

Page 4: ...ed it will cause injury INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation...

Page 5: ...irm button g Main menu button h Outdoor unit silent operation i Mode selection button automatic cooling heating dry fan only j Airflow rate setting button 3 2 2 To operate the wireless remote control...

Page 6: ...ng 2 In the indoor unit setting menu navigate to the open the front panel screen using and Open the front panel screen SEND 3 Press to confirm Result The front panel opens 4 Press again to close the f...

Page 7: ...ke sure the wireless router is close enough to the unit and nothing obstructs the signal Menu Description ON Wireless LAN ON AP mode RUN mode SSID KEY connection setting OFF Wireless LAN OFF EXIT Exit...

Page 8: ...connection was unsuccessful 1 Navigate to the RESET screen using and Press to confirm your selection Result The setting is reset to the factory default Reset screen RESET 2 Press to exit to the home s...

Page 9: ...ation During heating operation frost might occur on the outdoor unit and decrease the heating capacity In that case the system automatically switches to defrosting operation to remove the frost During...

Page 10: ...e mechanism will break The movable range of the flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swin...

Page 11: ...l airflow to ON 2 appears on the bottom of the home screen The flaps horizontal blades and louvers vertical blades will begin to swing Vertical airflow ON Horizontal airflow ON 3 To use fixed position...

Page 12: ...ono operation reduces power consumption of the outdoor unit by limiting the rotation speed of the compressor If power consumption is already low Econo operation will NOT further reduce power consumpti...

Page 13: ...unit s internal clock is NOT set to the correct time the ON timer OFF timer and weekly timer will NOT operate correctly The clock must be set again After a circuit breaker has turned the unit OFF Afte...

Page 14: ...played 3 Change CANCEL to TIME using 4 Go to the hour setting using and change the hour setting using and in 24 hour format 5 Go to the minutes setting using and change the minutes setting using and i...

Page 15: ...week with 4 day entries is displayed The new entry is present in the entry list The unit turns ON or OFF at the set time The entry list is sorted by time 9 For ON timer you can also set the temperatur...

Page 16: ...oner or air filter be sure to stop operation and turn all power supplies OFF Otherwise an electrical shock and injury may result WARNING To prevent electrical shocks or fire Do NOT rinse the unit Do N...

Page 17: ...ergent diluted in lukewarm water Dry the air filters in the shade Be sure to remove the titanium apatite deodorising and silver particle filters It is recommended to clean the air filters every 2 week...

Page 18: ...tact your dealer WARNING Stop operation and shut OFF the power if anything unusual occurs burning smells etc Leaving the unit running under such circumstances may cause breakage electrical shock or fi...

Page 19: ......

Page 20: ...3P485919 15W 2021 12 Copyright 2021 Daikin Verantwortung f r Energie und Umwelt...

Reviews: