Outdoor Unit / RK(X)H-C, ARK(X)H-C, R(Y)N-C
SiENBE04-401A
214
Removal Procedure
3.8
Removal of Compressor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1. Remove the parts around
the compressor.
Be careful so as not to burn
the compressor terminals or
the name plate.
1
Remove the terminal
cover and the lead
wires of the
compressor so as not
to be burnt out by a gas
brazing machine.
2. Remove the compressor.
1
The mounting nut for
the compressor is only
one piece.
Remove the four way valve
and the electronic expansion
valve also so as not to be
burnt out.
2
Remove the nut by an
open-end wrench.
Terminal cover
(R4077)
(R4078)
Compressor
(R4079)
Summary of Contents for FTKS20CVMB