![Daikin FTKS20CVMB Service Manual Download Page 149](http://html1.mh-extra.com/html/daikin/ftks20cvmb/ftks20cvmb_service-manual_3264185149.webp)
Check
SiENBE04-401A
140
Service Diagnosis
5.1.3 Thermistor Resistance Check
Check No.6
Remove the connectors of the thermistors on the PCB, and measure the resistance of each
thermistor using tester.
The relationship between normal temperature and resistance is shown in the graph and the
table below.
Thermistor R25°C=20k
Ω
B=3950
Temperature (°C)
–20
211.0 (k
Ω
)
–15
150
–10
116.5
–5
88
0
67.2
5
51.9
10
40
15
31.8
20
25
25
20
30
16
35
13
40
10.6
45
8.7
50
7.2
Resistance range
Tester
150
100
50
-15
15
30
45
0
(°C)
(R1437)
(k
Ω)
(R25=20k
Ω, B=3950)