SiENBE04-401A
Indoor Unit
Removal Procedure
165
1.6
Install of Drain Plug
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Disconnect drain hose.
The drain pan is integrated
with the bottom plate.
2
Pull out the drain plug in
the left on the drain pan
by hand.
3
Insert the drain hose,
Push it into the inner part
firmly.
4
Push the drain plug into
the right by Allen
wrench.
Push it into the inner part
firmly.
Drain
plug
(R2553)
Allen wrench(4 mm)
(R2555)