SiENBE04-401A
Outdoor Unit / RK(X)S-C, ARK(X)S-C
Removal Procedure
179
2.3
Removal of Reactor and Partition Plate
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the outer panels.
Remove the electrical
box.
1. Remove the reactor.
1
Loosen the screw.
Lift and remove the
reactor.
2. Remove the partition
plate.
1
Loosen the 2 screws.
Reactor
Partition plate
Summary of Contents for FTKS20CVMB
Page 19: ...List of Functions SiENBE04 401A 10 List of Functions...
Page 45: ...Specifications SiENBE04 401A 36 Specifications...
Page 81: ...Control Specification SiENBE04 401A 72 Function and Control...
Page 111: ...Instruction SiENBE04 401A 102 System Configuration...
Page 155: ...Check SiENBE04 401A 146 Service Diagnosis...
Page 225: ...Outdoor Unit RK X H C ARK X H C R Y N C SiENBE04 401A 216 Removal Procedure...
Page 229: ...Others SiENBE04 401A 220 Others...