![background image](http://html1.mh-extra.com/html/daikin/fte09jv2s/fte09jv2s_service-manual_2459324019.webp)
Si04-960
Removal of Fan Rotor / Fan Motor
Removal Procedure
17
7. Removal of Fan Rotor / Fan Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
To remove right side
panel, remove the 3
screws.
When reassembling the fan
motor, provide as much as
5mm of play between the
side face of the rotor and the
bottom frame.
���
Insert the fan motor approx.
5mm
���
Tighten the screw until it
stops. Then give the screw
one more turn.
���
Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
���
Tighten the screw
completely if appropriate.
���
If not appropriate, go back to
���
.
2
Disengage the hook
and remove the right
side panel.
(R2556)
(R2557)
Right side
panel
5mm
Side face of rotor
(R2808)
Side face of
bottom frame
(R9582)
Hook
(R2558)
(R2559)