![background image](http://html1.mh-extra.com/html/daikin/fte09jv2s/fte09jv2s_service-manual_2459324010.webp)
Removal of Electrical Box / PCB / Swing Motor
Si04-960
8
Removal Procedure
4. Removal of Electrical Box / PCB / Swing Motor
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
Remove the front grille.
1. Remove the electrical box.
1
Disconnect the
connecting wires.
2
Remove the screw on
the wire fixture.
Pay attention to the direction
of the retainer of the
thermistor so that the
retainer does not touch the
harness.
3
Disconnect the
connectors for fan
motor [S1] [S7].
4
Disconnect the
connector for swing
motor [S6].
5
Pull out the indoor heat
exchanger thermistor.
Terminal board
Indoor heat exchanger
thermistor
Swing motor
Earth screw
[S1]
[S7]
[S6]
(R18517)
Wire
fixture
(R18518)
Indoor heat
exchanger
thermistor
Retainer of
thermistor
[S1]
Connector
for fan motor
[S7]
Connector
for fan motor
[S6]
Connector
for swing
motor
(R18519)