408
FTX-N/U, FVXS-N, FDMQ-R Series EDUS091558E
3P124623-1E
13
OPERATION MODE
The following five operation control modes can be selected along with the temperature setting and operation mode
by remote controller, for a total of twenty different modes. These twenty modes are set and displayed with control
modes of 0 to 19. (For further details, see
EXAMPLE OF OPERATION SCHEDULE
on the next page.)
•
ON/OFF control impossible by remote controller.....Use this mode when operating and stopping from the
central remote controller only. (ON/OFF control by the
remote controller is disabled.)
•
Only OFF control possible by remote controller ......Use this mode when executing the operation only by the
central remote controller, and executing only the stop by
remote controller.
•
Centralized ..............................................................Use this mode when executing the operation only by the
central remote controller, and executing start/stop freely
by remote controller during the preset hours.
•
Individual .................................................................Use this mode when executing start/stop both by central
remote controller and remote controller.
•
Timer operation possible by remote controller......... Use this mode when executing start/stop by remote con-
troller during the preset hours, and not starting operation
by the central remote controller at the programmed time
of system start.
[HOW TO SELECT THE CONTROL MODE]
•
Select whether to accept or to reject the operation from the remote controller regarding the operation, stop, tem-
perature setting and operation mode setting, respectively, and determine the particular control mode from the
rightmost column of the table below.
Example
Operation by remote
controller (at time of
unified operation by
centralized control)
Operation by remote
controller (at time of
unified operation by
centralized control)
Operation
mode setting
by remote
controller
Temperature
control by
remote
controller
Stop by
remote
controller
[Rejection]
[Rejection]
[Rejection] [Acceptance]
[Acceptance]
The control
mode is “ 1 ”.
Summary of Contents for FDMQ-R Series
Page 1: ... Heat Pump Split Type Air Conditioners FTX N U FVXS N FDMQ R Series EDUS091558E ...
Page 2: ......
Page 17: ...FTX N U FVXS N FDMQ R Series EDUS091558E 15 C 3D123383 FTX24UVJU C 3D123379 FTX18UVJU ...
Page 19: ...FTX N U FVXS N FDMQ R Series EDUS091558E 17 3D112919B FDMQ18 24RVJU 3D112918B FDMQ12RVJU ...
Page 20: ...18 FTX N U FVXS N FDMQ R Series EDUS091558E 3D049611A BRC082A43 C 3D091305A BRC1E73 ...
Page 22: ...20 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107983A RXL24UMVJUA 3D123362 RXL18UMVJUA ...
Page 25: ...FTX N U FVXS N FDMQ R Series EDUS091558E 23 3D112629A FDMQ12 18 24RVJU ...
Page 32: ...30 FTX N U FVXS N FDMQ R Series EDUS091558E 3D107985A RXL24UMVJUA ...
Page 59: ...FTX N U FVXS N FDMQ R Series EDUS091558E 57 3D113126 FDMQ18RVJU ...
Page 60: ...58 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113128 FDMQ24RVJU ...
Page 62: ...60 FTX N U FVXS N FDMQ R Series EDUS091558E 3D113129 FDMQ24RVJU ...
Page 65: ...FTX N U FVXS N FDMQ R Series EDUS091558E 63 3D123455 FTX18UVJU 3D100354 FTX15NMVJU ...
Page 66: ...64 FTX N U FVXS N FDMQ R Series EDUS091558E 3D094737 FVXS09NVJU 3D074866A FTX24UVJU ...
Page 67: ...FTX N U FVXS N FDMQ R Series EDUS091558E 65 3D094777A FVXS15NVJU 3D094766 FVXS12NVJU ...
Page 70: ...68 FTX N U FVXS N FDMQ R Series EDUS091558E 3D123453 RXL18UMVJUA 3D100636 RXL15QMVJUA ...
Page 71: ...FTX N U FVXS N FDMQ R Series EDUS091558E 69 3D123454 RXL24UMVJUA ...
Page 394: ...392 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A ...
Page 395: ...FTX N U FVXS N FDMQ R Series EDUS091558E 393 1P124687 1A ...
Page 396: ...394 FTX N U FVXS N FDMQ R Series EDUS091558E 1P124687 1A ...
Page 397: ...FTX N U FVXS N FDMQ R Series EDUS091558E 395 1P124687 1A ...
Page 401: ...FTX N U FVXS N FDMQ R Series EDUS091558E 399 3P124623 1E 4 Fig 6 Fig 5 Fig 8 Fig 7 ...
Page 412: ...410 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 15 ...
Page 422: ...420 FTX N U FVXS N FDMQ R Series EDUS091558E 3P124623 1E 25 Fig 9 Fig 12 Fig 10 Fig 11 ...
Page 423: ...FTX N U FVXS N FDMQ R Series EDUS091558E 421 3P124623 1E 26 Fig 14 Fig 13 Fig 16 Fig 15 ...
Page 425: ...FTX N U FVXS N FDMQ R Series EDUS091558E 423 1P126474 1B ...
Page 426: ...424 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B ...
Page 427: ...FTX N U FVXS N FDMQ R Series EDUS091558E 425 1P126474 1B ...
Page 428: ...426 FTX N U FVXS N FDMQ R Series EDUS091558E 1P126474 1B ...
Page 433: ...FTX N U FVXS N FDMQ R Series EDUS091558E 431 3P162015 1A ...
Page 434: ...432 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A ...
Page 435: ...FTX N U FVXS N FDMQ R Series EDUS091558E 433 3P162015 1A ...
Page 436: ...434 FTX N U FVXS N FDMQ R Series EDUS091558E 3P162015 1A ...
Page 455: ...FTX N U FVXS N FDMQ R Series EDUS091558E 453 3P400464 1 ...
Page 457: ...FTX N U FVXS N FDMQ R Series EDUS091558E 455 3P561172 1 ...
Page 459: ...FTX N U FVXS N FDMQ R Series EDUS091558E 457 3P534932 1B ...
Page 469: ...FTX N U FVXS N FDMQ R Series EDUS091558E 467 3P436077 1 ...
Page 471: ...FTX N U FVXS N FDMQ R Series EDUS091558E 469 3P436078 1 ...
Page 472: ...470 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436079 1 14 26 KPS067A44 Snow Hood Outlet ...
Page 473: ...FTX N U FVXS N FDMQ R Series EDUS091558E 471 3P436079 1 ...
Page 475: ...FTX N U FVXS N FDMQ R Series EDUS091558E 473 3P436071 1 ...
Page 477: ...FTX N U FVXS N FDMQ R Series EDUS091558E 475 3P436072 1 ...
Page 478: ...476 FTX N U FVXS N FDMQ R Series EDUS091558E 3P436073 1 14 29 KPS063A47 Snow Hood Outlet ...
Page 479: ...FTX N U FVXS N FDMQ R Series EDUS091558E 477 3P436073 1 ...
Page 480: ...478 FTX N U FVXS N FDMQ R Series EDUS091558E ...
Page 481: ......
Page 482: ......
Page 483: ......