2 About the box

Installation and operation manual

4

FCAHG71~140FVEB

Split system air conditioners

4P429472-1 – 2015.12

Wiring instruction sheet

▪ Instructions  on  how  to  connect  the  optional  sensor  kit  and

decoration panels

▪ Format: Paper (in the box of the indoor unit)

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

For the installer

2

About the box

2.1

Indoor unit

2.1.1

To remove the accessories from the
indoor unit

a

e

f

d

c

b

h

j

i

g

k

l

m

o

n

a

Paper pattern for installation (upper part of packing)

b

General safety precautions

c

Indoor unit installation and operation manual

d

Installation guide

e

Washers for hanger brackets

f

Screws (to temporarily attach the paper pattern for
installation to the indoor unit)

g

Cable ties

h

Metal clamp

i

Insulation piece (drain pipe)

j

Sealing pads: Large (drain pipe), medium 1 (gas pipe),
medium 2 (liquid pipe), small (electrical wiring)

k

Drain hose

l

Insulation piece: Small (liquid pipe)

m

Insulation piece: Large (gas pipe)

n

Wiring instruction sheet (for the connection of the optional
sensor kit and decoration panels)

o

Wire harness for the self‑cleaning decoration panel

3

About the units and options

3.1

About the indoor unit

Use the system in the following temperature and humidity ranges for
safe and effective operation.

Cooling

Heating

Outdoor
temperature

–15~50°C DB

–19~21°C DB

–20~15.5°C WB

Indoor
temperature

18~35°C DB

12~28°C WB

10~27°C DB

Indoor humidity

≤80%

(a)

(a)

To avoid condensation and water dripping out of the unit. If
the temperature or the humidity is beyond these conditions,
safety devices may be put in action and the air conditioner
may not operate.

3.2

System layout

NOTICE

Design  of  the  system  must  not  be  done  at  temperatures
below –15°C.

f g 

b

h

i

a

d

e

c

a

Indoor unit

b

Outdoor unit

c

User interface

d

Suction air

e

Discharge air

f

Refrigerant interconnection cable

g

Drain pipe

h

Earth wiring

i

Suction grille and air filter

4

Preparation

4.1

Preparing installation site

4.1.1

Installation site requirements of the
indoor unit

INFORMATION

The sound pressure level is less than 70 dBA.

CAUTION

Appliance not accessible to the general public, install it in a
secured area, protected from easy access.

This  unit,  both  indoor  and  outdoor,  is  suitable  for
installation 

in 

commercial 

and 

light 

industrial

environment.

Spacing

. Mind the following requirements:

Summary of Contents for FCAHG71FVEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAHG71FVEB FCAHG100FVEB FCAHG125FVEB FCAHG140FVEB...

Page 2: ...a ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmi...

Page 3: ...o clean the air outlet and outside panels 15 12 2 About the refrigerant 16 12 3 After sales service and warranty 16 12 3 1 Warranty period 16 12 3 2 Recommended maintenance and inspection 16 13 Troubl...

Page 4: ...truction sheet for the connection of the optional sensor kit and decoration panels o Wire harness for the self cleaning decoration panel 3 About the units and options 3 1 About the indoor unit Use the...

Page 5: ...with a fresh air intake kit Install the fresh air intake kit always before installing the unit Decoration panel Install the decoration panel always after installing the unit Ceiling strength Check wh...

Page 6: ...on and cause water to drip 5 1 2 Guidelines when installing the drain piping Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the...

Page 7: ...temporarily connect the user interface and power supply to the unit When electrical wiring is not finished yet 1 Temporarily connect electrical wiring Remove the switch box cover a Connect the user i...

Page 8: ...3 3 To connect the electrical wiring on the indoor unit NOTICE Follow the wiring diagram delivered with the unit located at the inside of the service cover For instructions on how to connect the decor...

Page 9: ...losed all corners open optional blocking pad kit required Setting Air volume when thermostat control is OFF This setting must correspond with the needs of the user It determines the fan speed of the i...

Page 10: ...ng the BRC1E52 or BRC1E53 user interface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backli...

Page 11: ...d the currently set temperature is not displayed The wiring is disconnected or there is a wiring error between power supply and outdoor unit between outdoor unit and indoor units between indoor unit a...

Page 12: ...s used see the its wiring diagram Symbols X1M Main terminal Earth wiring 15 Wire number 15 Field wire Field cable 12 2 Connection continues on page 12 column 2 1 Several wiring possibilities Option No...

Page 13: ...grille and air filter 10 User interface CAUTION Never touch the internal parts of the controller Do not remove the front panel Some parts inside are dangerous to touch and appliance problems may happe...

Page 14: ...tem starts operating To stop 3 Press the ON OFF button on the user interface once again Result The operation lamp goes out and the system stops operating NOTICE Do not turn off power immediately after...

Page 15: ...ce Discoloration and deformation 1 Open the suction grille 1 2 Remove the air filter 1 2 3 3 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a soft bru...

Page 16: ...eep your air conditioner in operation as long as possible Contact your dealer for more information When asking your dealer for an intervention always state The complete model name of the air condition...

Page 17: ...rection does not correspond with the user interface display The fan direction does not swing This is because the unit is being controlled by the micro computer 13 1 4 Symptom White mist comes out of a...

Page 18: ...normal condition This continues for one minute 13 1 14 Symptom The compressor in the outdoor unit does not stop after a short heating operation This is to prevent refrigerant from remaining in the com...

Page 19: ......

Page 20: ...4P429472 1 2015 12 Copyright 2015 Daikin...

Reviews: