background image

8 Technical data

Installation and operation manual

12

FCAHG71~140FVEB

Split system air conditioners

4P429472-1 – 2015.12

8

Technical data

Latest information can be found in the technical engineering data.

8.1

Piping diagram: Indoor unit

b

a

c

d

a

Liquid pipe connection

b

Gas pipe connection

c

Filter

d

Heat exchanger

8.2

Wiring diagram: Indoor unit

The wiring diagram is delivered with the unit, located at the inside of
the service cover.

Notes:

1

In case using central remote controller, connect it to the unit
in accordance with the attached installation manual.

2

In case of main/sub changeover. See the installation manual
attached to remote controller.

3

Shows only in case of protected pipes. Use H07RN in case of
no protection.

4

When connecting the input wires from outside, forced off or
on/off control operation can be selected by the remote
controller. See installation manual for more details.

5

Connect power of adapter for wiring to terminal block (X2M)
of indoor unit directly.

6

X35A, X39A, X70A are connected when the optional
accessories are being used. In case an auto cleaning panel is
used, see the its wiring diagram.

Symbols:

X1M

Main terminal

Earth wiring

15

Wire number 15

Field wire

Field cable

**

/12.2

Connection ** continues on page 12 column 2

1

Several wiring possibilities

Option

Not mounted in switch box

Wiring depending on model

PCB

Colours:

BLK

Black

WHT

White

RED

Red

Legend:

A1P

Main PCB

A2P

Adapter PCB

A3P, A4P

*

Sensor kit PCB

A5P, A6P

Receiver/display PCB

A7P

*

Adapter for wiring

BS1 (A6P)

Push button (ON/Off)

C105 (A1P)

Capacitor

DS1 (A1P)

DIP switch

F1U (A7P)

Fuse B, 5 A 250 V

F2U (A7P)

Fuse B, 5 A 250 V

HAP (A1P)

Running LED (service monitor – green)

H1P (A6P)

LED (On – red)

H2P (A6P)

LED (timer – green)

H3P (A6P)

LED (filter sign – red)

H4P (A6P)

LED (defrost – orange)

H5P (A6P)

LED (element cleaning – red)

H6P (A6P)

LED (ventilation cleaning – green)

KCR (A7P)

Magnetic relay

KFR (A7P)

Magnetic relay

KHuR (A7P)

Magnetic relay (Hu)

K2R

Magnetic relay

M1F

Fan motor (indoor)

M1P

Motor (drain pump)

M*S

Motor (swing flap)

PS (A1P)

Power supply

R1T

Thermistor (air)

R2T

Thermistor (liquid piping)

R3T

Thermistor (coil)

RC (A1P)

Signal receiver circuit

SS1 (A5P)

Selector switch (emergency)

SS2 (A5P)

Selector switch (wireless address set)

S1L

Float switch

TC (A1P)

Signal transmission circuit

V1R (A1P)

Diode module

X1A (A7P)

Connector (power supply for option PCB)

X2A (A7P)

PCB connector (sensor kit)

X24A (A1P)

PCB connector (wireless remote controller)

Summary of Contents for FCAHG71FVEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAHG71FVEB FCAHG100FVEB FCAHG125FVEB FCAHG140FVEB...

Page 2: ...a ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmi...

Page 3: ...o clean the air outlet and outside panels 15 12 2 About the refrigerant 16 12 3 After sales service and warranty 16 12 3 1 Warranty period 16 12 3 2 Recommended maintenance and inspection 16 13 Troubl...

Page 4: ...truction sheet for the connection of the optional sensor kit and decoration panels o Wire harness for the self cleaning decoration panel 3 About the units and options 3 1 About the indoor unit Use the...

Page 5: ...with a fresh air intake kit Install the fresh air intake kit always before installing the unit Decoration panel Install the decoration panel always after installing the unit Ceiling strength Check wh...

Page 6: ...on and cause water to drip 5 1 2 Guidelines when installing the drain piping Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the...

Page 7: ...temporarily connect the user interface and power supply to the unit When electrical wiring is not finished yet 1 Temporarily connect electrical wiring Remove the switch box cover a Connect the user i...

Page 8: ...3 3 To connect the electrical wiring on the indoor unit NOTICE Follow the wiring diagram delivered with the unit located at the inside of the service cover For instructions on how to connect the decor...

Page 9: ...losed all corners open optional blocking pad kit required Setting Air volume when thermostat control is OFF This setting must correspond with the needs of the user It determines the fan speed of the i...

Page 10: ...ng the BRC1E52 or BRC1E53 user interface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backli...

Page 11: ...d the currently set temperature is not displayed The wiring is disconnected or there is a wiring error between power supply and outdoor unit between outdoor unit and indoor units between indoor unit a...

Page 12: ...s used see the its wiring diagram Symbols X1M Main terminal Earth wiring 15 Wire number 15 Field wire Field cable 12 2 Connection continues on page 12 column 2 1 Several wiring possibilities Option No...

Page 13: ...grille and air filter 10 User interface CAUTION Never touch the internal parts of the controller Do not remove the front panel Some parts inside are dangerous to touch and appliance problems may happe...

Page 14: ...tem starts operating To stop 3 Press the ON OFF button on the user interface once again Result The operation lamp goes out and the system stops operating NOTICE Do not turn off power immediately after...

Page 15: ...ce Discoloration and deformation 1 Open the suction grille 1 2 Remove the air filter 1 2 3 3 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a soft bru...

Page 16: ...eep your air conditioner in operation as long as possible Contact your dealer for more information When asking your dealer for an intervention always state The complete model name of the air condition...

Page 17: ...rection does not correspond with the user interface display The fan direction does not swing This is because the unit is being controlled by the micro computer 13 1 4 Symptom White mist comes out of a...

Page 18: ...normal condition This continues for one minute 13 1 14 Symptom The compressor in the outdoor unit does not stop after a short heating operation This is to prevent refrigerant from remaining in the com...

Page 19: ......

Page 20: ...4P429472 1 2015 12 Copyright 2015 Daikin...