3

FCAHG71~140FVEB
Split system air conditioners
4P429472-1 – 2015.12

Table of Contents

1 About the documentation

3

1.1

About this document..................................................................

3

For the installer

4

2 About the box

4

2.1

Indoor unit .................................................................................

4

2.1.1

To remove the accessories from the indoor unit.........

4

3 About the units and options

4

3.1

About the indoor unit .................................................................

4

3.2

System layout ............................................................................

4

4 Preparation

4

4.1

Preparing installation site ..........................................................

4

4.1.1

Installation site requirements of the indoor unit ..........

4

5 Installation

5

5.1

Mounting the indoor unit............................................................

5

5.1.1

Guidelines when installing the indoor unit...................

5

5.1.2

Guidelines when installing the drain piping.................

6

5.2

Connecting the refrigerant piping ..............................................

7

5.2.1

To connect the refrigerant piping to the indoor unit ....

7

5.3

Connecting the electrical wiring.................................................

8

5.3.1

Guidelines when connecting the electrical wiring .......

8

5.3.2

Specifications of standard wiring components............

8

5.3.3

To connect the electrical wiring on the indoor unit......

8

6 Configuration

9

6.1

Field settings .............................................................................

9

7 Commissioning

10

7.1

Checklist before commissioning ................................................

10

7.2

To perform a test run .................................................................

10

7.3

Error codes when performing a test run ....................................

11

8 Technical data

12

8.1

Piping diagram: Indoor unit .......................................................

12

8.2

Wiring diagram: Indoor unit .......................................................

12

For the user

13

9 About the system

13

9.1

System layout ............................................................................

13

10 User interface

13

11 Operation

13

11.1

Operation range ........................................................................

13

11.2

Operating the system ................................................................

13

11.2.1

About operating the system ........................................ 13

11.2.2

About cooling, heating, fan only, and automatic
operation ..................................................................... 13

11.2.3

About the heating operation........................................ 14

11.2.4

To operate the system ................................................ 14

11.3

Using the dry program ...............................................................

14

11.3.1

About the dry program ................................................ 14

11.3.2

To use the dry program............................................... 14

11.4

Adjusting the air flow direction...................................................

14

11.4.1

About the air flow flap ................................................. 14

12 Maintenance and service

14

12.1

Cleaning the air filter, suction grille, air outlet and outside
panels  .......................................................................................

15

12.1.1

To clean the air filter ................................................... 15

12.1.2

To clean the suction grille ........................................... 15

12.1.3

To clean the air outlet and outside panels ................... 15

12.2

About the refrigerant................................................................... 16

12.3

After-sales service and warranty ................................................ 16

12.3.1

Warranty period ........................................................... 16

12.3.2

Recommended maintenance and inspection............... 16

13 Troubleshooting

16

13.1

Symptoms that are not air conditioner troubles .......................... 17

13.1.1

Symptom: The system does not operate ..................... 17

13.1.2

Symptom: The fan strength does not correspond to
the setting .................................................................... 17

13.1.3

Symptom: The fan direction does not correspond to
the setting .................................................................... 17

13.1.4

Symptom: White mist comes out of a unit (Indoor
unit) .............................................................................. 17

13.1.5

Symptom: White mist comes out of a unit (Indoor
unit, outdoor unit) ......................................................... 17

13.1.6

Symptom: The user interface display reads "U4" or
"U5" and stops, but then restarts after a few minutes .. 17

13.1.7

Symptom: Noise of air conditioners (Indoor unit)......... 17

13.1.8

Symptom: Noise of air conditioners (Indoor unit,
outdoor unit)................................................................. 17

13.1.9

Symptom: Noise of air conditioners (Outdoor unit) ...... 17

13.1.10 Symptom: Dust comes out of the unit .......................... 17

13.1.11 Symptom: The units can give off odours...................... 17

13.1.12 Symptom: The outdoor unit fan does not spin ............. 18

13.1.13 Symptom: The display shows "88"............................... 18

13.1.14 Symptom: The compressor in the outdoor unit does

not stop after a short heating operation ....................... 18

14 Relocation

18

15 Disposal

18

1

About the documentation

1.1

About this document

Target audience

Authorised inst end users

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry  and  on  farms,  or  for
commercial use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation and operation manual:

▪ Installation and operation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer and user reference guide:

▪ Preparation  of  the  installation,  technical  specifications,

reference data,…

▪ Detailed  step-by-step  instructions  and  background  information

for basic and advanced usage

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Summary of Contents for FCAHG71FVEB

Page 1: ...Installation and operation manual Split system air conditioners English Installation and operation manual Split system air conditioners FCAHG71FVEB FCAHG100FVEB FCAHG125FVEB FCAHG140FVEB...

Page 2: ...a ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vastavuses j rgmi...

Page 3: ...o clean the air outlet and outside panels 15 12 2 About the refrigerant 16 12 3 After sales service and warranty 16 12 3 1 Warranty period 16 12 3 2 Recommended maintenance and inspection 16 13 Troubl...

Page 4: ...truction sheet for the connection of the optional sensor kit and decoration panels o Wire harness for the self cleaning decoration panel 3 About the units and options 3 1 About the indoor unit Use the...

Page 5: ...with a fresh air intake kit Install the fresh air intake kit always before installing the unit Decoration panel Install the decoration panel always after installing the unit Ceiling strength Check wh...

Page 6: ...on and cause water to drip 5 1 2 Guidelines when installing the drain piping Make sure condensation water can be evacuated properly This involves General guidelines Connecting the drain piping to the...

Page 7: ...temporarily connect the user interface and power supply to the unit When electrical wiring is not finished yet 1 Temporarily connect electrical wiring Remove the switch box cover a Connect the user i...

Page 8: ...3 3 To connect the electrical wiring on the indoor unit NOTICE Follow the wiring diagram delivered with the unit located at the inside of the service cover For instructions on how to connect the decor...

Page 9: ...losed all corners open optional blocking pad kit required Setting Air volume when thermostat control is OFF This setting must correspond with the needs of the user It determines the fan speed of the i...

Page 10: ...ng the BRC1E52 or BRC1E53 user interface When using any other user interface see the installation manual or service manual of the user interface NOTICE Do not interrupt the test run INFORMATION Backli...

Page 11: ...d the currently set temperature is not displayed The wiring is disconnected or there is a wiring error between power supply and outdoor unit between outdoor unit and indoor units between indoor unit a...

Page 12: ...s used see the its wiring diagram Symbols X1M Main terminal Earth wiring 15 Wire number 15 Field wire Field cable 12 2 Connection continues on page 12 column 2 1 Several wiring possibilities Option No...

Page 13: ...grille and air filter 10 User interface CAUTION Never touch the internal parts of the controller Do not remove the front panel Some parts inside are dangerous to touch and appliance problems may happe...

Page 14: ...tem starts operating To stop 3 Press the ON OFF button on the user interface once again Result The operation lamp goes out and the system stops operating NOTICE Do not turn off power immediately after...

Page 15: ...ce Discoloration and deformation 1 Open the suction grille 1 2 Remove the air filter 1 2 3 3 Clean the air filter Use a vacuum cleaner or wash with water If the air filter is very dirty use a soft bru...

Page 16: ...eep your air conditioner in operation as long as possible Contact your dealer for more information When asking your dealer for an intervention always state The complete model name of the air condition...

Page 17: ...rection does not correspond with the user interface display The fan direction does not swing This is because the unit is being controlled by the micro computer 13 1 4 Symptom White mist comes out of a...

Page 18: ...normal condition This continues for one minute 13 1 14 Symptom The compressor in the outdoor unit does not stop after a short heating operation This is to prevent refrigerant from remaining in the com...

Page 19: ......

Page 20: ...4P429472 1 2015 12 Copyright 2015 Daikin...