background image

Table of Contents

Installation manual

3

FBA35~140A2VEB
Split system air conditioners
4P456962-1C – 2017.04

Table of Contents

1 About the documentation

3

1.1

About this document..................................................................

3

2 About the box

3

2.1

Indoor unit .................................................................................

3

2.1.1

To remove the accessories from the indoor unit.........

3

3 About the units and options

4

3.1

System layout ............................................................................

4

4 Preparation

4

4.1

Preparing installation site ..........................................................

4

4.1.1

Installation site requirements of the indoor unit ..........

4

5 Installation

5

5.1

Mounting the indoor unit............................................................

5

5.1.1

Precautions when mounting the indoor unit................

5

5.1.2

Guidelines when installing the indoor unit...................

5

5.1.3

Guidelines when installing the ducting........................

6

5.1.4

Guidelines when installing the drain piping.................

6

5.2

Connecting the refrigerant piping ..............................................

8

5.2.1

To connect the refrigerant piping to the indoor unit ....

8

5.3

Connecting the electrical wiring.................................................

8

5.3.1

Guidelines when connecting the electrical wiring .......

8

5.3.2

Specifications of standard wiring components............

9

5.3.3

To connect the electrical wiring on the indoor unit......

9

6 Configuration

10

6.1

Field settings .............................................................................

10

7 Commissioning

11

7.1

Checklist before commissioning ................................................

11

7.2

To perform a test run .................................................................

11

7.3

Error codes when performing a test run ....................................

12

8 Disposal

12

9 Technical data

12

9.1

Wiring diagram ..........................................................................

13

1

About the documentation

1.1

About this document

INFORMATION

Make sure that the user has the printed documentation and
ask him/her to keep it for future reference.

Target audience

Authorised installers

INFORMATION

This appliance is intended to be used by expert or trained
users  in  shops,  in  light  industry,  and  on  farms,  or  for
commercial and household use by lay persons.

Documentation set

This  document  is  part  of  a  documentation  set.  The  complete  set
consists of:

General safety precautions:

▪ Safety instructions that you must read before installing

▪ Format: Paper (in the box of the indoor unit)

Indoor unit installation manual:

▪ Installation instructions

▪ Format: Paper (in the box of the indoor unit)

Installer reference guide:

▪ Preparation of the installation, good practices, reference data,…

▪ Format:  Digital  files  on 

http://www.daikineurope.com/support-

and-manuals/product-information/

Latest revisions of the supplied documentation may be available on
the regional Daikin website or via your dealer.

The original documentation is written in English. All other languages
are translations.

Technical engineering data

▪ A 

subset

  of  the  latest  technical  data  is  available  on  the  regional

Daikin website (publicly accessible).

▪ The 

full  set

  of  latest  technical  data  is  available  on  the  Daikin

extranet (authentication required).

2

About the box

2.1

Indoor unit

2.1.1

To remove the accessories from the
indoor unit

40×

e

d

b

a

c

f

g

h

i

j

k

l

a

Installation manual

b

Operation manual

c

General safety precautions

d

Washers for hanger bracket

e

Screws for duct flanges

f

Metal clamp

g

Sealing pads: Large (drain pipe), medium 1 (gas pipe),
medium 2 (liquid pipe)

h

Drain hose

i

Long sealing

j

Insulation piece: Small (liquid pipe)

k

Insulation piece: Large (gas pipe)

l

Tie wraps

Summary of Contents for FBA35A2VEB

Page 1: ...Installation manual Split system air conditioners English Installation manual Split system air conditioners FBA35A2VEB FBA50A2VEB FBA60A2VEB FBA71A2VEB FBA100A2VEB FBA125A2VEB FBA140A2VEB...

Page 2: ...v e cu condi ia ca acestea s fie utilizate n conformitate cu instruc iunile noastre skladni z naslednjimi standardi in drugimi normativi pod pogojem da se uporabljajo v skladu z na imi navodili on vas...

Page 3: ...get audience Authorised installers INFORMATION This appliance is intended to be used by expert or trained users in shops in light industry and on farms or for commercial and household use by lay perso...

Page 4: ...mmable gas may leak out If the gas leaks out and stays around the air conditioner a fire may break out 4 1 1 Installation site requirements of the indoor unit INFORMATION The sound pressure level is l...

Page 5: ...f the flange to protect the air filter from damage during maintenance of the filter a b c 5 mm a Air inlet duct b Inside of the flange c Fixing screw Ceiling strength Check whether the ceiling is stro...

Page 6: ...crews a b b a e e d d c a Connection screw accessory b Flange field supply c Main unit d Insulation field supply e Aluminium tape field supply Filter Be sure to attach an air filter inside the air pas...

Page 7: ...pipe 5 Wind the large sealing pad insulation around the metal clamp and drain hose and fix it with cable ties 6 Connect the drain piping to the drain hose 4 mm A A A A A A f 6 5 2 c e 4 b a d b a d c...

Page 8: ...The R32 refrigerant if applicable in this unit is mildly flammable a a Refer to the outdoor unit specifications for the type of refrigerant to be used Pipe length Keep refrigerant piping as short as p...

Page 9: ...ctrical interference the distance between both wiring should always be at least 50 mm NOTICE Be sure to keep the power line and transmission line apart from each other Transmission wiring and power su...

Page 10: ...1 1 22 RZQSG71L RZASG100M 2 1 65 2 RZQSG100L RZASG125M 4 3 33 3 2 32 2 2 05 RZQSG125L RZASG140M 4 3 33 3 2 32 2 2 05 RZQSG140L Combination FBA100A FBA125A FBA140A RZAG71M RZQG71L RZAG100M 1 0 73 RZQG1...

Page 11: ...tem before the following checks are OK You read the complete installation instructions as described in the installer reference guide The indoor units are properly mounted In case a wireless user inter...

Page 12: ...unit has NOT been done correctly the following error codes may be displayed on the user interface Error code Possible cause Nothing displayed the currently set temperature is not displayed The wiring...

Page 13: ...ADPROTECTOR D V D DIODE Q M THERMOSWITCH DB DIODEBRIDGE R RESISTOR DS DIPSWITCH R T THERMISTOR E H HEATER RC RECEIVER F U FU FORCHARACTERISTICS REFERTOPCBINSIDEYOURUNIT FUSE S C LIMITSWITCH FG CONNECT...

Page 14: ......

Page 15: ......

Page 16: ...4P456962 1C 2017 04 Copyright 2017 Daikin...

Reviews: