  D

–EIMAC00907–16EN - 5/20 

This manual is an important supporting document for qualified personnel but it is not intended to replace such personnel. 

 

Thank you for purchasing this chiller 

 

READ 

THIS 

MANUAL 

CAREFULLY 

BEFORE 

INSTALLING AND STARTING UP THE UNIT.  
IMPROPER  INSTALLATION  COULD  RESULT  IN 
ELECTRIC  SHOCK,  SHORT-CIRCUIT,  LEAKS,  FIRE 
OR  OTHER  DAMAGE  TO  THE  EQUIPMENT  OR 
INJURE TO PEOPLE. 
THE 

UNIT 

MUST 

BE 

INSTALLED 

BY 

PROFESSIONAL OPERATOR/TECHNICIAN  
UNIT  STARTUP  HAS  TO  BE  PERFORMED  BY 
AUTHORIZED AND TRAINED PROFESSIONAL 
ALL 

ACTIVITIES 

HAVE 

TO 

BE 

PERFORMED 

ACCORDING TO LOCAL LAWS AND REGULATION. 

UNIT 

INSTALLATION 

AND 

START 

UP 

IS 

ABOSOLUTELY  FORBIDDEN  IF  ALL  INSTRUCTION 
CONTAINED IN THIS MANUAL ARE NOT CLEAR. 

IF 

CASE 

OF 

DOUBT 

CONTACT 

THE 

MANUFACTURER  REPRESENTATIVE  FOR  ADVICE 
AND INFORMATION. 

Description 

The unit you bought is a

n “air cooled chiller”, a machine aimed 

to  cool  water  (or  water-glycol  mixture)  within  the  limits 
described  in  the  following.  The  unit  operation  is  based  on 
vapour compression, condensation and evaporation according 
to reverse Carnot cycle. The main components are: 

Screw compressor to rise the refrigerant vapour pressure 
from evaporation pressure to condensation pressure 

Evaporator,  where  the  low  pressure  liquid  refrigerant 
evaporates to cool the water 

Condenser,  where  high  pressure  vapour  condensate 
rejecting  heat  removed  from  the  chilled  water  in  the 
atmosphere thanks to an air cooled heat exchanger. 

Expansion  valve  allowing  to  reduced  the  pressure  of 
condensed  liquid  from  condensation  pressure  to 
evaporation pressure. 

General Information 

All  units  are  delivered  with 

wiring  diagrams

certified 

drawings,

 

nameplate

;  and 

DOC  (Declaration  Of 

Conformity)

;  these  documents  show  all  technical  data 

for  the  unit  you  have  bought  and  they 

MUST  BE 

CONSIDERED  ESSENTIAL  DOCUMENTS  OF  THIS 
MANUAL 

In  case  of  any  discrepancy  between  this  manual  and  the 
equipment’s  documents  please  refer  to  on  board  documents. 
In case of any doubt contact the manufacturer representative. 

 

The  purpose  of  this  manual  is  to  allow  the  installer  and  the 
qualified operator to ensure proper installation, commissioning 
and  maintenance  of  the  unit,  without  any  risk  to  people, 
animals and/or objects. 

Receiving the unit 

The  unit  must  be  inspected  for  any  possible  damage 
immediately  upon  reaching  final  place  of  installation.  All 
components  described  in the  delivery  note  must  be  inspected 
and checked.  
Should  the  unit  be  damaged,  do  not  remove  the  damaged 
material  and  immediately  report  the  damage  to  the 
transportation company and request  they inspect the unit..  
Immediately  report  the  damage  to  the  manufacturer 
representative, a set of photographs are helpful in recognizing 
responsibility 
Damage  must  not  be  repaired  before  the  inspection  of  the 
transportation company representative. 
Before  installing  the  unit,  check  that  the  model  and  power 
supply  voltage  shown  on  the  nameplate  are  correct. 
Responsibility  for  any  damage  after  acceptance  of  the  unit 
cannot be attributed to the manufacturer. 

Operating limits 

Storing Storage 

Environmental conditions must be within the following limits: 
Minimum ambient temperature 

-20°C 

Maximum ambient temperature 

57°C 

Maximum R.H. 

95% not condensing 

Storing below the minimum temperature may cause damage to 
components. Storing above the maximum temperature causes 
opening  of  safety  valves.  Storing  in  condensing  atmosphere 
may damage electronic components.

 

 
Operation 

Operation is allowed within the following limits: 
Evaporator  Leaving  Water  Temperature:  4…18°C  (Cool 
Mode), -

8…18°C (Cool with glycol, Ice Mode) 

Outside Ambient Temperature @ full load: 

 

Silver Efficiency Version: 10…47°C 

 

Gold Efficiency Version: -

18…50°C 

 

Platinum Efficiency Version: -

18…52°C 

Operational  envelope  can  be  extended  through  selection  of 
specific  options  (such  as  high  ambient  kit,  brine  version,  etc) 
which  allow  the  unit  to  operate  down  to  -8°C  evaporator 
leaving temperature and/or up to 52°C ambient temperature at 
full load. 
The  above  mentioned  values  represent  a  guideline,  please 
refer to the chiller selection software for real operating limits for 
the specific model. 
 
As  a  general  rule,  The  unit  should  be  operated  with  an 
evaporator water flow rate between 50% and 140% of nominal 
flow  rate  (at  standard  operating  conditions),  however  check 
with  the  chiller  selection  software  the  correct  minimum  and 
maximum allowed values for the specific model. 
Operation out of the mentioned limits may damage the unit. 
In case of doubts contact manufacturer representative. 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for EWAD TZ

Page 1: ...nverter Installation Operation and Maintenance Manual Air cooled chiller with inverter driven screw compressor EWAD TZ Refrigerant R 134a Original Instructions Installation Operation and Maintenance M...

Page 2: ...D EIMAC00907 16EN 2 20 A Typical refrigerant circuit Water inlet and outlet are indicative Please refer to the machine dimensional diagrams for exact water connections...

Page 3: ...D EIMAC00907 16EN 3 20 B Typical refrigerant circuit with heat recovery Water inlet and outlet are indicative Please refer to the machine dimensional diagrams for exact water connections...

Page 4: ...isolating valve 16 SAE Flare valve 17 Evaporator water inlet connection 18 Evaporator water outlet connection 19 2 Way charging valve 20 Heat Recovery Optional 21 Heat Recovery water outlet connectio...

Page 5: ...nance of the unit without any risk to people animals and or objects Receiving the unit The unit must be inspected for any possible damage immediately upon reaching final place of installation All comp...

Page 6: ...the electrical panel Single circuit unit Double circuits unit Label Identification 1 Manufacturer s logo 5 Cable tightening warning 2 Gas type 6 Non flammable gas symbol 3 Hazardous Voltage warning 7...

Page 7: ...the chiller in areas that could be dangerous during maintenance operations such as platforms without parapets or railings or areas not complying with the clearance requirements around the chiller Nois...

Page 8: ...s be avoided In case the AVM s are not adjustable spring type are normally not adjustable the flatness of the unit frame must be guaranteed by using metal plate spacers Before unit commissioning the f...

Page 9: ...for post installation maintenance operations Figure 3 shows the minimum space required Vertical air discharge must not be obstructed If the unit is surrounded by walls or obstacles of the same height...

Page 10: ...uit on the right is working quite normally In order to avoid the hot air recirculation due to dominant winds the installation where all chillers are aligned to the dominant wind is preferred see figur...

Page 11: ...e water system the Installer has to guarantee the cleaning of the water pipes between the water filter and the evaporator 9 Evaporator has an electrical resistance with a thermostat that ensures prote...

Page 12: ...an be installed either on the inlet or outlet water piping The purpose of the flow switch is to stop the unit in the event of interrupted water flow thus protecting the evaporator from freezing The ma...

Page 13: ...of all the safety devices During the unit s initial start up phase a technician authorized by the manufacturer is available to answer any questions and to give instructions as to the correct operating...

Page 14: ...enance Plan for Critical Application and or Highly Aggressive Environment List of Activities Note 8 Weekly Monthly Note 1 Yearly Seas Onal Note 2 General Reading of operating data Note 3 X Visual insp...

Page 15: ...old bleach or acid cleaners should not be used to clean E coated coils These cleaners can be very difficult to rinse out of the coil and can accelerate corrosion and attack the E coating If there is d...

Page 16: ...refrigerant quantity charged in the unit is listed on a silver sticker inside the electrical panel Periodical inspections for refrigerant leaks may be required depending on European or local legislat...

Page 17: ...D EIMAC00907 16EN 17 20...

Page 18: ...D EIMAC00907 16EN 18 20...

Page 19: ...D EIMAC00907 16EN 19 20...

Page 20: ...of its content and the products and services presented therein Specification are subject to change without prior notice Refer to the data communicated at the time of the order Daikin Applied Europe S...